Failures and remedial measures
Failure
Cause
Remedial measure
The
splitting
force
is
insufficient to split the log.
1. The log/splitting blade is in an
incorrect position.
2. The splitting force is not great
enough.
1. Fix the position of the
log/splitting blade.
2. Contact the retailer.
The in-feed conveyor belt does
not move.
1. The belt is too loose.
1. Tension the belt according to
the instructions in Section
5.4.1.
The out-feed conveyor belt
does not move
1. The belt is too loose (the lower
drive roller moves).
2. The lower drive roller is jammed
and does not move.
1. Tighten the belt according to
the instructions in Section
4.4.
2. Disconnect the machine
from the power source and
remove the obstruction.
The cutting chain does not
properly penetrate the wood.
1. The saw chain is dull.
2. The saw bar is crooked.
1. Sharpen or replace the saw
chain.
2. File the bar to make it
straight.
The machine starts but none of
the
functions
work.
The
machine makes an abnormal
noise.
The electric motor runs in the
wrong direction.
See Section 3.2.2.
The electric motor does not
start.
1. The machine makes a loud
noise but does not start.
2. The thermal relay has tripped.
3. Starter fuse triggered.
4. The input cable is faulty.
1. The gear fuse has blown.
Replace it.
2. Reset the thermal relay with
the starter’s stop button.
3. Disconnect from the power
source and check the
starter relay.
4. Replace the cable.
The electric motor tends to
stop, and the thermal relay is
easily triggered.
1. The thermal relay is broken
or incorrectly adjusted.
Some other problem?
1. Contact the retailer.
The cutting or splitting function
does not work.
1. The machine guard is
open.
1. Close the guard
completely.
The
sawdust
blower
is
jammed.
1. Ensure that the cock is in
the ON position.
2. There is a chip or
obstruction in the sawdust
blower.
3.
The motor’s relief valve is
leaking (debris inside).
1. See Section
3.2.6
2.
Clean the blower’s
motor.
3. Open and clean the
adjustment cartridge.
The
machine’s
electrical
control does not work or works
unreliably
(sawing
button,
splitting button)
1. In a PTO machine, the 12
V plug is not connected to
the tractor (in an electrical
model, the 12 V plug is not
connected to the machine)
2. Guard open or sensor fault
3. Connection or grounding
fault in the tractor.
1. Connect plug. See
Section
3.2.1
or
3.2.2
2. Fully lower the guard
and check sensor
operation (Figure 60).
3. Check the connections
4.
Upper right in
Figure
23
. Determine the cause