05/12/16   TFL-B101Q DS (FL6)

100

0

25

50

75

SP1 SP2 SP3 SP4

Zero Span

SP2

SP1

SP3

SP4

2)  ADJUST THE SETPOINT FOR EACH RELAY 

The setpoint for each relay is set by the front panel buttons marked SP1, SP2, SP3 and 

SP4. When a front panel button is pressed and held down, the associated setpoint is direct-

ly changed. The direction of change will be either up or down, as indicated by the UP and 

DOWN indicator LEDs. After the indicator LED lights up there is a 0.5 second delay before 

any change occurs. To reverse the direction of change, release the button and then press 

down again. As there are no menus or sub-menus to navigate, the programming and setup 

is quick and easy. 

Setpoints are indicated on the bar display by an ON segment if the bar is below the set-

point and with an OFF segment if the bar display is above the setpoint.

Setpoint Adjust continued

Setting the Colors (For CHT or CVT Center Bar display options only)

100

212

0

32

SP1 SP2 SP3 SP4

Zero Span

Lo

output

Hi

Apply power

while holding down

SP1, SP2, SP3, SP4

SP2
SP1

SP3

SP4

100

212

0

32

SP1 SP2 SP3 SP4

Zero Span

Lo

output

Hi

Select required

color (i.e. orange)

SP1

100

212

0

32

SP1 SP2 SP3 SP4

Zero Span

Lo

output

Hi

Select required

color (i.e. Green)

SP2

100

212

0

32

SP1 SP2 SP3 SP4

Zero Span

Lo

output

Hi

Select required

color (i.e. Orange)

SP3

100

212

0

32

SP1 SP2 SP3 SP4

Zero Span

Lo

output

Hi

Select required

color (i.e. Red)

SP4

To comply with the latest safety requirements, the tri-color bargraph is designed like a traffic 

light, to display either red, orange or green, but only one color at a time.  When the bar reaches a 

selected color change point, the entire bar will change to the color designated for that zone.  This 

eliminates any ambiguity as to the signal status, especially just after transitioning to a new zone.

However, if two or more setpoints with differently specified colors are positioned at the same 

set point value, the color specified for the set point with the highest identifying number will be 

displayed. When set points are set to the same value, the SP4 color overrides the SP3 color, the 

SP3 color overrides the SP2 color, and the SP2 color overrides the SP1 color.

STEP A ENTER COLOR SET MODE

  Hold down ALL four setpoint buttons (SP1, SP2, SP3 and SP4) and apply power to the  

  meter. The meter will light up in the Color Set Mode. Release all the setpoint buttons.

STEP B SELECT COLOR FOR BAR ABOVE SETPOINT 1

  Hold down the SP1 button. The color of the bar segments below SP1 will cycle between red,  

  green and orange. Release the SP1 button when the bar is the required color. Now  

 

  Whenever the bar is above the SP1 level it will be this color. When the bar is below the SP1  

  level it will always be red.

STEP C SELECT COLOR FOR BAR ABOVE SETPOINT 2

  Hold down the SP2 button. The color of the bar segments below SP2 will cycle between red,  

  green and orange. Release the SP2 button when the bar is the required color. Now    

  whenever the bar is above the SP2 level it will be this color.

STEP D SELECT COLOR FOR BAR ABOVE SETPOINT 3

  Hold down the SP3 button. The color of the bar segments below SP3 will cycle between red,  

  green and orange. Release the SP3 button when the bar is the required color. Now  

 

  whenever the bar is above the SP3 level it will be this color.

STEP E  SELECT COLOR FOR BAR ABOVE SETPOINT 4

  Hold down the SP4 button. The color of the bar segments below SP4 will cycle between red,  

  green and orange. Release the SP4 button when the bar is the required color. Now    

  whenever the bar is above the SP4 level it will be this color.

STEP F  EXIT COLOR SET MODE

  Turn off the power to the meter for 5 seconds and then reapply the power. The bargraph will now work with the programmed colors.

Summary of Contents for TFL-B101Q

Page 1: ...ly AC DC Auto sensing wide range supply PS1 std 85 265 VAC 95 370 VDC 2 5W max 4 2W PS2 15 48 VAC 10 72 VDC 2 5W max 4 2W Operating Temp 0 to 60 C Storage Temp 20 C to 70 C Relative Humidity 95 non co...

Page 2: ...dia grams are used to visually assist in following programming steps The following symbols are used to represent the functions and displays of the meter When two fingers are shown side by side the tw...

Page 3: ...side the bar display area and by an OFF segment inside the bar display area Horizontal or Reverse Mounting Meters can be mounted horizontally in the panel and for those applica tions that require an o...

Page 4: ...driver to release two plastic catches on either side of the case and levering backwards Step 4 Starting with the top first insert a small flat bladed screw driver and carefully lever the plastic catc...

Page 5: ...the Scaling by pressing the ZERO and SPAN buttons simultaneously for two seconds Both scaling memories will be erased and an internal default scale factor will be loaded This provides a display of zer...

Page 6: ...libration of the meter it is best to start with a reset of the scaling STEP C RESET THE SCALING ON CHANNEL ONE 1 Apply power to the meter and press the CH1 ZERO and CH1 SPAN buttons simultaneously for...

Page 7: ...e Display Driver Board See the layout diagram on Page 4 and 14 for the exact location The steps to setup the setpoints are as follows 1 SELECT THE RELAY ACTIVATION MODE FOR EACH INSTALLED RELAY Make s...

Page 8: ...ity as to the signal status especially just after transitioning to a new zone However if two or more setpoints with differently specified colors are positioned at the same set point value the color sp...

Page 9: ...t the analog output as measured on the external multimeter to be the required value 20mA in this example When the HI button is pressed the UP or DOWN indicator LED shows the direction of change Releas...

Page 10: ...s 23 and 24 have a unique plug and socket outline to prevent cross connection The main board uses standard right angled connectors Replacement 2 3 and 4 pin plug connectors are available see Accessori...

Page 11: ...EXC Display Board Front SP1 SP2 SP3 SP4 Zero Span 0 10 20 30 40 50 60 70 80 90 100 Display Board Front SP1 SP2 SP3 SP4 Zero Span 0 10 20 30 40 50 60 70 80 90 100 Zero SP4 SP3 SP2 SP1 100 0 10 30 50 70...

Page 12: ...ated I Series input modules that have span or zero potentiometers can be interchanged between any I Series com patible meter without recalibration because all of the analog scaling and reference circu...

Page 13: ...fset 0 _ Increase Span Decrease 141E I Series Input Signal Conditioning Modules IF02 Line Frequency SPAN ZERO Frequency to Voltage Conversion 60 to 500VAC 269D IA12 AC Millivolt RMS Sigma Delta 371A A...

Page 14: ...re IS02 Pressure Load Cell 5 10VDC Exc 20 2mV V 4 6 wire 2 20 mV V 10V 5V 4W 6W EXC Pressure Transducer PRESSURE 151A IR03 Linear Potentiometer 1K min POTENTIOMETER 1K Minimum Digital Scaling Input Ex...

Page 15: ...tting Right angled Connector 6mm 0 24 10mm 0 39 26 5mm 1 05 Push On Connector for FI series IO board The adapter snaps on the 36x144 mm 1 42 x5 69 case and enables single unit or stack mounting in an...

Page 16: ...ader position 4 3 2 1 1 2 3 4 5 75 Turn Potentiometer 0 Equivalent Circuit Increase Zero Decrease 5 4 3 2 1 Decrease Zero Increase 1 2 3 4 5 75 Turn Potentiometer 0 Zero Pot Disabled SPAN Turn Clockwi...

Page 17: ...have one 10 Amp relay or two 5 Amp relays plus 16 bit analog output or an extra 5 Amp relay Auto sensing AC DC wide range power supplies 85 265 V AC 95 370 V DC or 18 36 V AC 9 60 V DC Quick easy mou...

Page 18: ...HAKARU PLUS CORPORATION Tel 81 6 6300 2195 Page 18 05 12 16 TFL B101Q DS FL6 Space...

Page 19: ...40 40 30 35 25 20 0 5 10 15 9x5 45 45 40 30 35 25 20 0 5 10 15 10x5 50 50 45 40 30 35 25 20 0 5 10 15 12 15 0 3 6 9 1 10 100 1000 1 5 15 150 1500 2 20 200 2000 2 5 25 250 2500 3 30 300 3000 4 40 400 4...

Page 20: ...e IS05 Pressure Load Cell 20 2mV V 5 10V Exc 4 wire IS06 Pressure Load Cell Ext Exc 20 2mV V 4 wire IS07 Pressure 20 2mV V with High Impedance and External Excitation IT03 RTD 100 Pt 2 3 4 wire 200 to...

Reviews: