HAKARU PLUS TFL-B101Q Manual Download Page 10

HAKARU PLUS CORPORATION Tel. 81-6-6300-2195 

Page 10

05/12/16   TFL-B101Q DS (FL6)

1  3  5  7  

2 4 6 8

9  

10

Socket for Input Signal

Conditioning Module

2
3

5

1

4

1
2
3
4
5
6
7
8
9

10

Input and output 
pins vary for 
different modules. 
Please see the 
specific module 
data sheet for 
details.

1.25 V 

Bandgap 

Reference

8
9

10
11
12
13
14
15

17
18
19
20
21

23

24

NO3

COM 1 & 3

NO1

NC1

NO4

COM 2 & 4

NO2

NC2

Analog –

Program Lock

Common

Dim

Display

Driver

Multiplexer

and 

Buffer 

Amplifier

Micro

Processor

1M

1M

0.1

0.1

GND

FL-B101Q Functional Diagram

Input Hi
Input Lo

+5VDC
-5VDC

+24VDC

Ref Hi

Analog Common

System Ground
MUXO

24 V Return

GND

+ 5 V

14 Bit 

Single 

Slope 

A to D

GND

+ 5 V

GND

+ 5 V

GND

Isolated 16 Bit Sigma Delta D to A

Select Header

mA

V

AC Neutral, – DC

AC Line, + DC

AC/DC Power Input

MOV's

10A

5A

+ 5 V

SP3

+ 5 V

SP1

MOV's

10A

5A

+ 5 V

SP4

+ 5 V

SP2

+15 V DC

CENTER 

ZERO

SELECT 
HEADER

RELAYS

ACTIVE ON

SELECT

HEADER

MODE 1

MODE 2

MODE 3

CTO CH2
CTO CH1

Relay 4

Relay 3

Relay 2

Relay 1

SP1 SP2 SP3 SP4

Zero Span

0

10

20

30

40

50

60

70

80

90

100

NTC

EMI Filter

Isolated 

Switching 

Supply

-5 V DC

+5 V DC

+24 V DC

ISO

GND

GND

+15 V DC

ISO

GND

!

WARNING

AC and DC power supply voltages are hazard-

ous. Make sure the power supply is isolated 

before connecting to the meter.

COM

1&3

NO3

SP3

NO

SP1/3

COM

SP1

NC

SP2

N1

SP1

NO

SP2/4

COM

SP2

NC

SP2

NO

LOCK

COMMON

DIM

NC1

SP3

COM

2&4

NC2

NO4

SP4

NO1

SP1

NO2

SP2

8 9 10 11 12 13 14 15

17 18 19 20 21

23 24

1-6

See Leopard Family Input

Signal Conditioning Moduls

Analog

Analog

Output –

AC

Neutral

AC 

Line

– DC

+ DC

or

This meter uses plug-in type screw terminal connectors 

for all input and output connections. The power supply 

connections (pins 23 and 24) have a unique plug and 

socket outline to prevent cross connection. The main 

board uses standard right-angled connectors.
Replacement 2-, 3-, and 4-pin plug connectors are 

available (see Accessories on page 16).

Input Signal – Pins 1 to 6 

Pins 1 to 6 are reserved for the input signal conditioner. 

See the data sheet for the selected input signal conditioner. 

Pins 8 to 15 – Relay Output Pins

Pin 8    SP3 NO.

 Normally Open 5 Amp Form A.

Pin 9    SP1/3 COM.

 Common for SP1 and SP3.

Pin 10   SP1 NC.

 Normally Closed 10 Amp Form C.

Pin 11   SP1 NO.

 Normally Open 10 Amp Form C.

Pin 12   SP4 NO.

 Normally Open 5 Amp Form A.

Pin 13   SP2/4 COM.

 Common for SP3 and SP4.

Pin 14   SP2 NC.

 Normally Closed 10 Amp Form C.

Pin 15   SP2 NO.

 Normally Open 10 Amp Form C.

Pins 17 to 21 – Rear Panel Switches

Pin 17   ANALOG OUTPUT (+).

 mA (0 to 20 mA/4 to 20 mA)  

 

or V (0 to 10 V) output is header selectable. 

Pin 18  ANALOG OUTPUT (–).

  mA (0 to 20 mA/4 to  

 

20 mA) or V (0 to 10 V) output is header selectable. 

Pin 19  Programming LOCK.

 By connecting the LOCK pin  

 

to the COMMON pin, the meter's programmed  

 

parameters can be viewed but not changed.

Pin 20  COMMON.

 To  activate the LOCK or DIM functions  

 

from the rear of the meter, the respective pins have  

 

to be connected to the COMMON pin. This pin is  

 

connected to the internal power supply ground.

Pin 21  DIM.

 By connecting the display dim (DIM) pin to 

 

the COMMON pin, the display brightness setting

 

is halved.

Pins 23 and 24 – AC/DC Power Input

Auto-sensing AC/DC power supply. For voltages between  

85-265 V AC / 95-370 V DC (PS1) or 18-48 V AC / 10-72 V 

DC (PS2).

Pin 23  AC Neutral / –DC.

 Neutral power supply line.

Pin 24  AC line / +DC.

 Live power supply line.

Functional Diagram

Connector Pinouts

Pin Descriptions

Note:  The sequence of setpoint outputs on meters shipped prior to 2002 

was 1-2-3-4.  The sequence is now 3-1-4-2, enabling delay on make 

(dom) and delay on break (dob) to be used with both Form “C” relays.

Summary of Contents for TFL-B101Q

Page 1: ...ly AC DC Auto sensing wide range supply PS1 std 85 265 VAC 95 370 VDC 2 5W max 4 2W PS2 15 48 VAC 10 72 VDC 2 5W max 4 2W Operating Temp 0 to 60 C Storage Temp 20 C to 70 C Relative Humidity 95 non co...

Page 2: ...dia grams are used to visually assist in following programming steps The following symbols are used to represent the functions and displays of the meter When two fingers are shown side by side the tw...

Page 3: ...side the bar display area and by an OFF segment inside the bar display area Horizontal or Reverse Mounting Meters can be mounted horizontally in the panel and for those applica tions that require an o...

Page 4: ...driver to release two plastic catches on either side of the case and levering backwards Step 4 Starting with the top first insert a small flat bladed screw driver and carefully lever the plastic catc...

Page 5: ...the Scaling by pressing the ZERO and SPAN buttons simultaneously for two seconds Both scaling memories will be erased and an internal default scale factor will be loaded This provides a display of zer...

Page 6: ...libration of the meter it is best to start with a reset of the scaling STEP C RESET THE SCALING ON CHANNEL ONE 1 Apply power to the meter and press the CH1 ZERO and CH1 SPAN buttons simultaneously for...

Page 7: ...e Display Driver Board See the layout diagram on Page 4 and 14 for the exact location The steps to setup the setpoints are as follows 1 SELECT THE RELAY ACTIVATION MODE FOR EACH INSTALLED RELAY Make s...

Page 8: ...ity as to the signal status especially just after transitioning to a new zone However if two or more setpoints with differently specified colors are positioned at the same set point value the color sp...

Page 9: ...t the analog output as measured on the external multimeter to be the required value 20mA in this example When the HI button is pressed the UP or DOWN indicator LED shows the direction of change Releas...

Page 10: ...s 23 and 24 have a unique plug and socket outline to prevent cross connection The main board uses standard right angled connectors Replacement 2 3 and 4 pin plug connectors are available see Accessori...

Page 11: ...EXC Display Board Front SP1 SP2 SP3 SP4 Zero Span 0 10 20 30 40 50 60 70 80 90 100 Display Board Front SP1 SP2 SP3 SP4 Zero Span 0 10 20 30 40 50 60 70 80 90 100 Zero SP4 SP3 SP2 SP1 100 0 10 30 50 70...

Page 12: ...ated I Series input modules that have span or zero potentiometers can be interchanged between any I Series com patible meter without recalibration because all of the analog scaling and reference circu...

Page 13: ...fset 0 _ Increase Span Decrease 141E I Series Input Signal Conditioning Modules IF02 Line Frequency SPAN ZERO Frequency to Voltage Conversion 60 to 500VAC 269D IA12 AC Millivolt RMS Sigma Delta 371A A...

Page 14: ...re IS02 Pressure Load Cell 5 10VDC Exc 20 2mV V 4 6 wire 2 20 mV V 10V 5V 4W 6W EXC Pressure Transducer PRESSURE 151A IR03 Linear Potentiometer 1K min POTENTIOMETER 1K Minimum Digital Scaling Input Ex...

Page 15: ...tting Right angled Connector 6mm 0 24 10mm 0 39 26 5mm 1 05 Push On Connector for FI series IO board The adapter snaps on the 36x144 mm 1 42 x5 69 case and enables single unit or stack mounting in an...

Page 16: ...ader position 4 3 2 1 1 2 3 4 5 75 Turn Potentiometer 0 Equivalent Circuit Increase Zero Decrease 5 4 3 2 1 Decrease Zero Increase 1 2 3 4 5 75 Turn Potentiometer 0 Zero Pot Disabled SPAN Turn Clockwi...

Page 17: ...have one 10 Amp relay or two 5 Amp relays plus 16 bit analog output or an extra 5 Amp relay Auto sensing AC DC wide range power supplies 85 265 V AC 95 370 V DC or 18 36 V AC 9 60 V DC Quick easy mou...

Page 18: ...HAKARU PLUS CORPORATION Tel 81 6 6300 2195 Page 18 05 12 16 TFL B101Q DS FL6 Space...

Page 19: ...40 40 30 35 25 20 0 5 10 15 9x5 45 45 40 30 35 25 20 0 5 10 15 10x5 50 50 45 40 30 35 25 20 0 5 10 15 12 15 0 3 6 9 1 10 100 1000 1 5 15 150 1500 2 20 200 2000 2 5 25 250 2500 3 30 300 3000 4 40 400 4...

Page 20: ...e IS05 Pressure Load Cell 20 2mV V 5 10V Exc 4 wire IS06 Pressure Load Cell Ext Exc 20 2mV V 4 wire IS07 Pressure 20 2mV V with High Impedance and External Excitation IT03 RTD 100 Pt 2 3 4 wire 200 to...

Reviews: