background image

HAKARU PLUS CORPORATION Tel. 81-6-6300-2195 

Page 20

05/12/16   TFL-B101Q DS (FL6)

BASIC MODEL #

DISPLAY

POWER SUPPLY

INPUT MODULES

ANALOG OUTPUT

RELAY OUTPUT

OPTIONS / ACCESSORIES

OA____

TFL-B101Q

Add to the basic model number the order code suffix for each standard option required. The last suffix is to 

indicate how many different special options and or accessories that you may require to be included with this product. 

Ordering Example: TFL-B101Q-RVR-PS1-IA01-OIC-R11

BASIC MODEL NUMBER

TFL-B101Q . .144x36mm, OMI 220, 101 Segment Bargraph, 4 Digit

Standard Options for this Model Number

Order Code Suffix 

Description 

DISPLAY

BHG  . . . . . . . . . Green LED Bargraph, Horizontal, Bottom position . . . . . . . . .

BHR  . . . . . . . . . Red LED Bargraph, Horizontal, Bottom position. . . . . . . . . . .

CHG  . . . . . . . . . Green LED Bargraph, Horizontal, Center position. . . . . . . . . .

CHR  . . . . . . . . . Red LED Bargraph, Horizontal, Center position  . . . . . . . . . . .

CHT  . . . . . . . . . Center Horizontal - Tri-Color. . . . . . . . . . . . . . . . . . . . . . . . . .

CVG  . . . . . . . . . Green LED Bargraph, Vertical, Center position . . . . . . . . . . . .

CVR  . . . . . . . . . Red LED Bargraph, Vertical, Center position

. . . . . . . . . .

CVT. . . . . . . . . . Center Vertical - Tri-Color . . . . . . . . . . . . . . . . . . . . . . . . . . . .

LVG . . . . . . . . . . Green LED Bargraph, Vertical, Left side . . . . . . . . . . . . . . . . .

LVR . . . . . . . . . . Red LED Bargraph, Vertical, Left side. . . . . . . . . . . . . . . . . . .

RVG  . . . . . . . . . Green LED Bargraph, Vertical, Right side . . . . . . . . . . . . . . . .

RVR. . . . . . . . . . Red LED Bargraph, Vertical, Right side  . . . . . . . . . . . . . . . . .

THG  . . . . . . . . . Green LED Bargraph, Horizontal, Top position . . . . . . . . . . . .

THR. . . . . . . . . . Red LED Bargraph, Horizontal, Top position  . . . . . . . . . . . . .

POWER SUPPLY

PS1

. . . . . . . . . .

85-265VAC/95-370VDC

. . . . . . . . . . . . . . . . . . . . . . . . . . . . 

PS2. . . . . . . . . . 15-48VAC/10-72VDC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

INPUT MODULES

Unless otherwise specified Hakaru will ship all modules precalibrated with factory pre-

selected ranges and/or scalings as shown in 

BOLD

 type.

IA01 . . AC-Volts Scaled RMS, 200/

600V

 AC  . . . . . . . . . . . . . . . . .

IA02 . . AC-Volts Scaled RMS, 200mV/

2V

/20V AC  . . . . . . . . . . . . .

IA03 . . AC-mA Scaled RMS, 2/

20

/200mA AC. . . . . . . . . . . . . . . . .

IA04 . . AC-Amps Scaled RMS, 

0-1 Amp AC (0-100.00)

. . . . . . . . .

IA05 . . AC-Amps Scaled RMS, 

0-5 Amp AC (0-100.00)

. . . . . . . . .

IA06 . . AC-Volts True RMS, 200/

600V

 AC  . . . . . . . . . . . . . . . . . . .

IA07 . . AC-Volts True RMS, 200mV/

2V

/20V AC  . . . . . . . . . . . . . . .

IA08 . . AC-mA True RMS, 2/

20

/200mA AC  . . . . . . . . . . . . . . . . . .

IA09 . . AC-Amps True RMS, 

0-1 Amp AC (0-100.00)

. . . . . . . . . . .

IA10 . . AC-Millivolt, Scaled RMS, 

100mV AC

. . . . . . . . . . . . . . . . .

IA11 . . AC-Amps True RMS, 

0-5 Amp AC (0-100.00)

. . . . . . . . . . .

IA12 . . AC-Millivolt, True RMS, 

100mV AC

. . . . . . . . . . . . . . . . . . .

ID01. . DC-Volts, 

2

/20/200V/Custom w/24V DC Exc. . . . . . . . . . . .

ID02. . DC-Millivolt, 20/50/

100

/200mV DC w/24V DC Exc. . . . . . . .

ID03. . DC-Milliamp, 2/

20

/200mA DC w/24V DC Exc  . . . . . . . . . . .

ID04. . DC-Amps, 

5A DC

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

ID05. . DC-Volts 

2

/20/200/Custom V DC w/Offset and 24V Exc. . . .

ID07. . DC-Milliamp, 2/

20

/200mA DC w/Offset and 24V Exc . . . . . .

ID09. . DC-Amps, 

1A DC

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  

IF02 . . Line Frequency, 50-500VAC, 199.9Hz, or optional 400Hz. . .

IGYZ* . . Universal Direct Pressure. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

*View the IG- Ordering Code on page 13 to determine the value for Y & Z (IGAZ to IGKZ)

IP01 . . Process Loop, 

4-20mA(0-100.00)

  . . . . . . . . . . . . . . . . . . .

IP02 . . Process Loop, 

4-20mA(0-100.00)

 w/24VDC Exc. . . . . . . . .

IP03 . . Process Input, 

1-5V DC(0-100.00)

 w/Offset, 24V Exc . . . . .

IP07 . . Universal Process 2V/5V/

10V

/20V/200V/2mA/20mA/Custom 

IPT1 . . Prototype Board for Custom Design . . . . . . . . . . . . . . . . . .

IR02 . . . 3-Wire Potentiometer 1KΩ min (0-F.S.). . . . . . . . . . . . . . . . . . .

IR03 . . . Linear Potentiometer, 3-wire, 1KΩ min . . . . . . . . . . . . . . . . . . .

IR05 . . Resistance 2KΩ  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

IS01 . . Strain Gage 5/10VDC Exc., 20/

2mV/V

4

/6-wire . . . . . . . . . 

IS02 . . Pressure 5/10VDC Exc., 20/

2mV/V

4

/6-wire  . . . . . . . . . . .

IS04 . . Pressure Ext Exc., 20/2mV/V, 

4

/6–wire . . . . . . . . . . . . . . . .

I

S05. . . Pressure/Load Cell 20/2mV/V, 5/10V Exc 4-wire . . . . . . . . . . . .

IS06 . . . Pressure/Load Cell Ext Exc., 20/2mV/V, 4-wire . . . . . . . . . . . . .

IS07 . . Pressure 20/2mV/V with High Impedance and External Excitation   

IT03 . . RTD, 100Ω Pt. 2/

3

/4-wire 

(-200 to 800°C)

. . . . . . . . . . . . .

IT04 . . RTD, 100Ω Pt. 2/

3

/4-wire 

(-200 to 1470°F)

  . . . . . . . . . . . .

IT05 . . RTD, 100Ω Pt. 2/

3

/4-wire 

(-190.0 to 199.0°F)

  . . . . . . . . . .

IT06 . . Thermocouple, J Type 

(0-1400 °F)

. . . . . . . . . . . . . . . . . . .

IT07 . . Thermocouple, K Type 

(0-1999°F)

  . . . . . . . . . . . . . . . . . . .

IT08 . . Thermocouple, J Type 

(0-760 °C)

. . . . . . . . . . . . . . . . . . . .

IT09 . . Thermocouple, K Type 

(0-1260°C)

. . . . . . . . . . . . . . . . . . .

ANALOG OUTPUT

OIC  . . . . . . . . . Isolated 16 Bit Current Output, 4-20mA  . . . . . . . . . . . . . .

OIV  . . . . . . . . . Isolated 16 Bit Voltage Output, 0-10VDC  . . . . . . . . . . . . .

RELAY  OUTPUT

R11 . . . . . . . . . Single 10A Form C Relay. . . . . . . . . . . . . . . . . . . . . . . . .

R12 . . . . . . . . . Dual 10A Form C Relays   . . . . . . . . . . . . . . . . . . . . . . . . .

R13 . . . . . . . . . Dual 10A Form C & One 5A Form A Relays. . . . . . . . . . . .

R14 . . . . . . . . . Dual 10A Form C & Dual 5A Form A Relays  . . . . . . . . . . .

R15 . . . . . . . . . Single 10A Form C & Dual 5A Form A Relays  . . . . . . . . . .

R16 . . . . . . . . . Single 10A Form C & Single 5A Form A Relays . . . . . . . . .

Ordering Information

WARRANTY

Hakaru warrants that its products are free from defects in material and workmanship under 

normal use and service for a period of one year from date of shipment. Hakaru’s obligations 

under this warranty are limited to replacement or repair, at its option, at its factory, of any of 

the products which shall, within the applicable period after shipment, be returned to Hakaru’s 

facility, transportation charges pre-paid, and which are, after examination, disclosed to the 

satisfaction of Hakaru to be thus defective. The warranty shall not apply to any equipment 

which shall have been repaired or altered, except by Hakaru, or which shall have been sub

-

jected to misuse, negligence, or accident. In no case shall Hakaru’s liability exceed the original 

purchase price. The aforementioned provisions do not extend the original warranty period of 

any product which has been either repaired or replaced by Hakaru.

USER’S RESPONSIBILITY

We are pleased to offer suggestions on the use of our various products either by way of 

printed matter or through direct contact with our sales/application engineering staff. However, 

since we have no control over the use of our products once they are shipped, NO WARRANTY 

WHETHER  OF  MERCHANTABILITY,  FITNESS  FOR  PURPOSE,  OR  OTHERWISE  is  made 

beyond the repair, replacement, or refund of purchase price at the sole discretion of Hakaru. 

Users shall determine the suitability of the product for the intended application before using, 

and the users assume all risk and liability whatsoever in connection therewith, regardless 

of any of our suggestions or statements as to application or construction. In no event shall 

Hakaru’s liability, in law or otherwise, be in excess of the purchase price of the product.

Hakaru cannot assume responsibility for any circuitry described. No circuit patent or software 

licenses are implied. Hakaru reserves the right to change circuitry, operating software, speci-

fications, and prices without notice at any time.

Local Distributor Address

HAKARU PLUS CORPORATION

        3-5-11 TAGAWA YODOGAWA-KU OSAKA, JAPAN
        Postal Code: 532-0027
        Tel: 81-6-6300-2195; Fax: 81-6308-7766

TVR Instruments Ltd

143 Butt Road 

Colchester CO3 3DP, United Kingdom

Tel: +44 (0)1206 575755

Email: [email protected]

Web: www.tvri.co.uk

Summary of Contents for TFL-B101Q

Page 1: ...ly AC DC Auto sensing wide range supply PS1 std 85 265 VAC 95 370 VDC 2 5W max 4 2W PS2 15 48 VAC 10 72 VDC 2 5W max 4 2W Operating Temp 0 to 60 C Storage Temp 20 C to 70 C Relative Humidity 95 non co...

Page 2: ...dia grams are used to visually assist in following programming steps The following symbols are used to represent the functions and displays of the meter When two fingers are shown side by side the tw...

Page 3: ...side the bar display area and by an OFF segment inside the bar display area Horizontal or Reverse Mounting Meters can be mounted horizontally in the panel and for those applica tions that require an o...

Page 4: ...driver to release two plastic catches on either side of the case and levering backwards Step 4 Starting with the top first insert a small flat bladed screw driver and carefully lever the plastic catc...

Page 5: ...the Scaling by pressing the ZERO and SPAN buttons simultaneously for two seconds Both scaling memories will be erased and an internal default scale factor will be loaded This provides a display of zer...

Page 6: ...libration of the meter it is best to start with a reset of the scaling STEP C RESET THE SCALING ON CHANNEL ONE 1 Apply power to the meter and press the CH1 ZERO and CH1 SPAN buttons simultaneously for...

Page 7: ...e Display Driver Board See the layout diagram on Page 4 and 14 for the exact location The steps to setup the setpoints are as follows 1 SELECT THE RELAY ACTIVATION MODE FOR EACH INSTALLED RELAY Make s...

Page 8: ...ity as to the signal status especially just after transitioning to a new zone However if two or more setpoints with differently specified colors are positioned at the same set point value the color sp...

Page 9: ...t the analog output as measured on the external multimeter to be the required value 20mA in this example When the HI button is pressed the UP or DOWN indicator LED shows the direction of change Releas...

Page 10: ...s 23 and 24 have a unique plug and socket outline to prevent cross connection The main board uses standard right angled connectors Replacement 2 3 and 4 pin plug connectors are available see Accessori...

Page 11: ...EXC Display Board Front SP1 SP2 SP3 SP4 Zero Span 0 10 20 30 40 50 60 70 80 90 100 Display Board Front SP1 SP2 SP3 SP4 Zero Span 0 10 20 30 40 50 60 70 80 90 100 Zero SP4 SP3 SP2 SP1 100 0 10 30 50 70...

Page 12: ...ated I Series input modules that have span or zero potentiometers can be interchanged between any I Series com patible meter without recalibration because all of the analog scaling and reference circu...

Page 13: ...fset 0 _ Increase Span Decrease 141E I Series Input Signal Conditioning Modules IF02 Line Frequency SPAN ZERO Frequency to Voltage Conversion 60 to 500VAC 269D IA12 AC Millivolt RMS Sigma Delta 371A A...

Page 14: ...re IS02 Pressure Load Cell 5 10VDC Exc 20 2mV V 4 6 wire 2 20 mV V 10V 5V 4W 6W EXC Pressure Transducer PRESSURE 151A IR03 Linear Potentiometer 1K min POTENTIOMETER 1K Minimum Digital Scaling Input Ex...

Page 15: ...tting Right angled Connector 6mm 0 24 10mm 0 39 26 5mm 1 05 Push On Connector for FI series IO board The adapter snaps on the 36x144 mm 1 42 x5 69 case and enables single unit or stack mounting in an...

Page 16: ...ader position 4 3 2 1 1 2 3 4 5 75 Turn Potentiometer 0 Equivalent Circuit Increase Zero Decrease 5 4 3 2 1 Decrease Zero Increase 1 2 3 4 5 75 Turn Potentiometer 0 Zero Pot Disabled SPAN Turn Clockwi...

Page 17: ...have one 10 Amp relay or two 5 Amp relays plus 16 bit analog output or an extra 5 Amp relay Auto sensing AC DC wide range power supplies 85 265 V AC 95 370 V DC or 18 36 V AC 9 60 V DC Quick easy mou...

Page 18: ...HAKARU PLUS CORPORATION Tel 81 6 6300 2195 Page 18 05 12 16 TFL B101Q DS FL6 Space...

Page 19: ...40 40 30 35 25 20 0 5 10 15 9x5 45 45 40 30 35 25 20 0 5 10 15 10x5 50 50 45 40 30 35 25 20 0 5 10 15 12 15 0 3 6 9 1 10 100 1000 1 5 15 150 1500 2 20 200 2000 2 5 25 250 2500 3 30 300 3000 4 40 400 4...

Page 20: ...e IS05 Pressure Load Cell 20 2mV V 5 10V Exc 4 wire IS06 Pressure Load Cell Ext Exc 20 2mV V 4 wire IS07 Pressure 20 2mV V with High Impedance and External Excitation IT03 RTD 100 Pt 2 3 4 wire 200 to...

Reviews: