_________________________________ ___EN__________________________________41
Adequate connection of water pipes and electric wires;
The leaking of cooling pipe has been tested;
Efficient water discharge pipe.
Full insulation protection;
Adequate earthing;
Adequate power source;
No obstacle to air inlet and air outlet;
There is no air in the water pipeline and all the valves are in open
position;
Efficient electric leak protection is operating;
Water inlet pressure is sufficient(≥0,15MPa)
After being connected to the water pipeline system and the electric power
system, the hot water tank has to be filled up with water from the household water
supply system.
The tank must be filled up with water before switching on the
heating.
During filling the tank up with water, open the hot water valve of the closet
tap while keep all the other valves closed. Then open the closing valve mounted in
the cold water pipe (
Figure 7.3-1., item No. 1.
). The tank is filled up when water
appears on the tap. For flushing purposes, the water must be flown for some
minutes, then you can close the valve of the hot water.
PLEASE TURN TO A TECHNICIAN TO CHECK THE FIRST HEATING.
Perform an eye check to decide whether connections of edges and pipe
fittings are leaking or not
– and tighten them carefully, if necessary. The appliance
can be connected to the electric power system only after this check. In order to
switch the heat pump of the water heater in a mode, press the
ON/OFF
key located
on the control panel. Before setting the clock and other parameters or programs,
please follow the instructions of chapter 4.
FOR PERSONNEL AUTHORIZED TO PERFORM MAINTENANCE
10.
MAINTENANCE INSTRUCTIONS
WARNING!
Please follow the general warnings and safety precautions listed in
the previous chapter and please comply with them strictly.
Any operations and activities has to be performed by qualified personnel (so
they have to possess expertise as required by effective regulations).
WARNING!
Before repair or maintenance, the appliance always must be switched off and
the external switch must be turned into “OFF” position.
10.4.
Appliance discharge
Water drainage can be performed through the blow off button (faucet) mounted in
front of the hot water tank or through the combined safety valve, turning the button in
the direction indicated by the arrow, through the water outlet tube. Before water
drainage, the valve closing pipeline connection and the cold water faucet have to be
closed, while the hot water faucet has to be kept opened during water drainage.
ATTENTION! HOT WATER MAY OUTFLOW DURING WATER DRAINAGE!
If you perceive water leaking or any malfunctioning from the interior of the appliance,
switch it off from the water pipeline system immediately with the help of the closing
valve.