____________________________________________EN________________________________________6
water pipe. In case of connecting red copper pipes to the water pipeline system,
the use of insulating intermediate pieces is compulsory.
The hot water tank should be connected to the electric system only through
permanent connection. It is forbidden to apply any wall socket.
The current of the electric system has to be connected to the hot water tank
through an all-pole disconnection device, which has at least 3mm separation
distance in all poles. This separator equipment must to connect in fixed grid
wiring.
For personnel authorízed to perform the maintanance and change of the electric
wiring system of the appliance to avoid any electrical shock. Only manufacturer
or the authorized service or simmilar skilled budies can do this kind of
maintenence ont he appliance.
2.1.
Summary table of technical data
QUALITY CERTIFICATION LABEL-TECHNICAL DATA
Type
HB300
HB300C
Sizes: diameter/height/depth
Ø661/1930/720
Water pipeline connection
G3/4
Circulation pipe branch connection
G3/4
Rated volume
295 l
287 l
Rated operation pressure
0,6 MPa
Safety valve max. opening pressure
0,7 MPa
Largest water supply pressure
0,525 MPa
Smallest required network pressure
0,01 MPa
Standby energy use at 60
o
C
2500 Wh/24h
Weight
124 kg
141 kg
Pipe coal
Pipe coal connection
Rp3/4
Pipe coal heatable volume
287 l
Pipe coal surface
-
1,5 m
2
Pipe coal flow resistance
130 mbar
Top performance
510 l/the first 10
minutes
Durable performance
1100 l/h
Durable performance
45 kW
Heat pump
Type
air (indoor)
Air duct connection (inlet/outlet)
Ø190 mm
Condenser
safety heat exchanger
GWP / Cooling agent / quantity
1300 / R134a / 1100 g
Max. Power Consumption
1200W
Average Power Consumption
850W
Air flow
~500m
3
/h
Reachable static pressure
80 Pa
External static pressure range where the appliance has been
examined
1013
– 1050 hPa
Max. suction side pressure
1,0 MPa
Max. blow side pressure
2,5 MPa
Minimum space required for operation (in case of operation without
air duct
20 m
3
Operation temperature range
-7 - +43
o
C
Max. water temperature
60
o
C