MANDO Adapt T812
Removal
Order h49 7144.907-333
69
C
Changing part variant, direct screw connection
D
Changing part variant central axial screw connection
D1 Fixing screws, changing part variant, central, axial screw connec-
tion
DANGER
Serious injuries caused by workpieces being
ejected centrifugally if the coupling ring is not se-
cured properly!
Always secure the coupling ring with the rotary
extractor ring / a changing part.
Depending on the version of changing parts, they can be re-
moved as follows.
If necessary, in addition to these operating instruc-
tions, you should also read and follow the operating
instructions for the relevant changing parts.
1. As described in the »Preparing the machine for re-
moval« chapter, prepare for the following steps.
2. Move the clamping device into release position.