MANDO Adapt T812
Commissioning
64
Order h49 7144.907-333
Conduct a clamping force measurement.
8.4 Workpiece
DANGER
Serious injuries caused by parts being ejected
centrifugally if level of workpiece clamping is in-
sufficient!
Never utilize the full clamping reserve.
Do not exceed the permitted maximum clamping
reserve stroke.
The remaining clamping reserve must always be
adapted to suit the workpiece material provided
and its possible distortions.
WARNING
Crushing injuries to hands / fingers is workpiece
is installed incorrectly!
Do not place hands / fingers between workpiece
and clamping device.
Never reach into the clamping area.
CAUTION
Burns caused by high workpiece temperature!
Give preference to automatic loading.
Also wear the following items of personal protec-
tive equipment, in addition to the basic equip-
ment:
8.5 Procedure after a collision
In the event of a collision, the product and its components
must be checked for cracks and damage before being used
again.
For this, remove the product from the machine [see »Re-
moval of the product« chapter] and dismantle it [for level of
disassembly, see »Cleaning« chapter].