Intuoduction
Domestic air conditioner
1.2 Safety Cautions
Be sure to read the following safety cautions before conducting repair work.
The caution items are classified into “Warning” and “Caution”. The “Warning” items are especially important
since they can lead to death or serious injury if they are not followed closely. The “Caution” items can also lead
to serious accidents under some conditions if they are not followed. Therefore, be sure to observe all the safety
caution items described below.
About the pictograms
△
This symbol indicates an item for which caution must be exercised.
The pictogram shows the item to which attention must be paid.
○
This symbol indicates a prohibited action.
The prohibited item or action is shown inside or near the symbol.
●
This symbol indicates an action that must be taken, or an instruction.
The instruction is shown inside or near the symbol.
After the repair work is complete, be sure to conduct a test operation to ensure that the equipment operates
Normally, and explain the cautions for operating the product to the customer.
1.2.1 Caution in Repair
Warning
Be sure to disconnect the power cable plug from the plug socket before disassembling the equipment for
a repair.
Working on the equipment that is connected to a power supply can cause an electrical shook.
If it is necessary to supply power to the equipment to conduct the repair or inspecting the circuits, do not
touch any electrically charged sections of the equipment.
If the refrigerant gas discharges during the repair work, do not touch the discharging refrigerant gas .The
refrigerant gas can cause frostbite.
When disconnecting the suction or discharge pipe of the compressor at the welded section, release the
refrigerant gas completely at a well-ventilated place first.
If there is a gas remaining inside the compressor , the refrigerant gas or refrigerating machine oil
discharges when the pipe is disconnected, and it can cause injury.
If the refrigerant gas leaks during the repair work, ventilate the area. The refrigerant gas can generate
toxic gases when it contacts flames.
The step-up capacitor supplies high-voltage electricity to the electrical components of the outdoor unit.
Be sure to discharge the capacitor completely before conducting repair work . A charged capacitor can
cause an electrical shock.
Do not start or stop the air conditioner operation by plugging or unplugging the power cable plug.
Plugging or unplugging the power cable plug to operate the equipment can cause an electrical shock or
fire.
382
Summary of Contents for Super Match Series
Page 1: ...Super Match SYJS 11 2015REV D Edition 2015 11 3U19FS2ERA 3U24GS2ERA 4U30HS2ERA 5U34HS2ERA...
Page 3: ...Super Match Part 1 General Information 1 Indoor Outdoor unit models 3 2 Features 4 2...
Page 7: ...Super Match Super Match Part 2 Indoor units 1 4 way cassette type 9 2 Duct indoor type 90 6...
Page 10: ...Super Match 2 Specification 9...
Page 11: ...Super Match Super Match 10...
Page 12: ...Super Match 11...
Page 13: ...Super Match Super Match 3 Dimension AB09CS2ERA AB12CS2ERA S AB18CS2ERA S AB24ES1ERA 12...
Page 24: ...Super Match 8 Installation 23...
Page 25: ...Super Match Super Match 24...
Page 26: ...Super Match 25...
Page 27: ...Super Match Super Match 26...
Page 28: ...Super Match 27...
Page 30: ...Super Match 1 Features AD09 12SS1ERA N P AD18 24SS1ERA N P AD12 18MS1ERA AD24MS2ERA 29...
Page 40: ...Super Match AD09SS1ERA N P AD09SS1ERA N P AD18SS1ERA N P AD24SS1ERA N P 39...
Page 53: ...Super Match Super Match 52...
Page 54: ...Super Match 53...
Page 55: ...Super Match Super Match 54...
Page 56: ...Super Match 55...
Page 57: ...Super Match Super Match 56...
Page 58: ...Super Match AD12MS1ERA AD18MS1ERA AD24MS2ERA 57...
Page 59: ...Super Match Super Match 58...
Page 60: ...Super Match 59...
Page 61: ...Super Match Super Match 60...
Page 62: ...Super Match 61...
Page 63: ...Super Match Super Match 62...
Page 90: ...Super Match 9 Maintenance WARNING CAUTION 89...
Page 91: ...Super Match Super Match 90...
Page 92: ...Super Match 91...
Page 93: ...Super Match Super Match 92...
Page 94: ...Super Match Items to Be Checked 93...
Page 95: ...Super Match Super Match 94...
Page 96: ...Super Match 95...
Page 99: ...Super Match Super Match 98...
Page 100: ...Super Match 99...
Page 101: ...Super Match F 100...
Page 102: ...Super Match 101...
Page 103: ...Super Match 102...
Page 106: ...Super Match 105...
Page 107: ...Super Match 106...
Page 110: ...Super Match PCB 0151800175 AD09 24SS1ERA N P AD12MS1ERA AD18MS1ERA AD24MS2ERA 109...
Page 119: ...Super Match Power module 0150400643A 3U24GS2ERA Power module 0150400643B 3U19FS2ERA 118...
Page 120: ...Super Match Filter board 0150400699 3U19FS1ERA 3U24GS2ERA 4U30HS1ERA 5U34HS1ERA 119...
Page 177: ...Piping diagrams Domestic air conditioner 5 Pinping diagrams 176...
Page 180: ...Connector Wiring diagrams Domestic air conditioner 179...
Page 232: ...Piping diagrams Domestic air conditioner 5 Pinping diagrams 231...
Page 235: ...Connector Wiring diagrams Domestic air conditioner 234...
Page 287: ...Piping diagrams Domestic air conditioner 5 Pinping diagrams 286...
Page 310: ...Seivice diagnosis Domestic air conditioner 9 Dimensional drawings 10 Center of gravity 309...
Page 339: ...Piping diagrams Domestic air conditioner 5 Pinping diagrams 338...
Page 391: ...Piping diagrams Domestic air conditioner 5 Pinping diagrams 390...
Page 443: ...Piping diagrams Domestic air conditioner 5 Pinping diagrams 442...