Parts and Functions Operation
CAUTION
Before opening the front grille, be sure
to stop the operation and turn the
breaker OFF.
Do not touch the metal parts on the
inside of the indoor unit, as it may result
in injury.
Air outlet selection switch
Operating
mode
Situation
Blowing pattern
Cool
mode
Heat
mode
At start or when air
temperature is low.
So that air does not come
into direct contact with
people.Air is blown upper
air outlet.
At start of operation
or other times when
the room is not fully
cooled.
Air is blown from the upper
and lower air outlets for
high speed cooling during
Cool mode, and for filling
the room with warm air
during Heat mode.
So that air does not come
into direct contact with
people, air is blown
upper air outlet, room
temperature is equalised
When the room has
become fully cool.
Air conditioner automatically decides the appropriate
blowing pattern depending on the operating mode
and situation.
During Dry and Fan mode, so that cold air does not
come into direct contact with people, air is blown upper
air outlet.
Regardless of the operating mode or situation, air
blows from the upper air outlet.
Use this switch when you do not want air coming
out of the lower air outlet. (While sleeping etc..)
Base Operation
temperature is below 16 C, do not use it in the
o
Test operation:
Use this switch in the test operation when the room
normal operation.
your finger from the switch: the cooling
Continue to press the test operation
switch for more than 5 seconds. After
you hear the "Pi" sound twice, release
operation starts with the air flow speed "Hi".
Emergency operation and test operation
Pi Pi
At times other than
below.
(Normal time.)
Test operation switch is the same as emergency switch.
In DRY mode, when room temperature becomes lower than
temp.2 C, unit will run intermittently at LOW speed
o
regardless of FAN setting.
Under the mode of auto operation, air conditioner will automatically
select Cool or Heat operation according to room temperature.
When FAN is set to AUTO the air conditioner automatically adjusts
the fan speed according to room temperature.
In FAN operation mode,the unit will not operate in COOL or HEAT
mode but only in FAN mode, AUTO is not available in FAN mode.
And temp. setting is disabled In FAN mode, sleep operation is not
available.
In HEAT mode, warm air will blow out after a short period of the
time due to cold-draft prevention function.When FAN is set to
AUTO, the air conditioner automatically adjusts the fan speed
according to room temperature.
AUTO
COOL
DRY
HEAT
FAN
Operation
Mode
Remote
Controller
Note
Press FAN button. For each press, fan speed
follows:
Remote controller:
Press
button
Every time the button is pressed, temp.setting
increase 1
o
C,if kept depressed, it will increase
rapidly
Every time the button is pressed, temp.setting
decrease
1
o
C,if kept depressed, it will
decrease rapidly
Select a desired temperature.
4.Fan speed selection
3.Select temp.setting
Air conditioner is running under displayed fan speed.
When FAN is set to AUTO, the air conditioner
automatically adjusts the fan speed according to room
temperature.
1. Unit start
Press ON/OFF on the remote controller, unit starts.
/
Remote controller
changes as
1
4
3
3
LOW
MED
HI
AUTO
2. Select operation mode
2
COOL button:Cooling mode
HEAT button: Heating mode
DRY button: Dehumidify mode
Display
circulated
Domestic air conditioner
System configuration
248
Summary of Contents for Super Match Series
Page 1: ...Super Match SYJS 11 2015REV D Edition 2015 11 3U19FS2ERA 3U24GS2ERA 4U30HS2ERA 5U34HS2ERA...
Page 3: ...Super Match Part 1 General Information 1 Indoor Outdoor unit models 3 2 Features 4 2...
Page 7: ...Super Match Super Match Part 2 Indoor units 1 4 way cassette type 9 2 Duct indoor type 90 6...
Page 10: ...Super Match 2 Specification 9...
Page 11: ...Super Match Super Match 10...
Page 12: ...Super Match 11...
Page 13: ...Super Match Super Match 3 Dimension AB09CS2ERA AB12CS2ERA S AB18CS2ERA S AB24ES1ERA 12...
Page 24: ...Super Match 8 Installation 23...
Page 25: ...Super Match Super Match 24...
Page 26: ...Super Match 25...
Page 27: ...Super Match Super Match 26...
Page 28: ...Super Match 27...
Page 30: ...Super Match 1 Features AD09 12SS1ERA N P AD18 24SS1ERA N P AD12 18MS1ERA AD24MS2ERA 29...
Page 40: ...Super Match AD09SS1ERA N P AD09SS1ERA N P AD18SS1ERA N P AD24SS1ERA N P 39...
Page 53: ...Super Match Super Match 52...
Page 54: ...Super Match 53...
Page 55: ...Super Match Super Match 54...
Page 56: ...Super Match 55...
Page 57: ...Super Match Super Match 56...
Page 58: ...Super Match AD12MS1ERA AD18MS1ERA AD24MS2ERA 57...
Page 59: ...Super Match Super Match 58...
Page 60: ...Super Match 59...
Page 61: ...Super Match Super Match 60...
Page 62: ...Super Match 61...
Page 63: ...Super Match Super Match 62...
Page 90: ...Super Match 9 Maintenance WARNING CAUTION 89...
Page 91: ...Super Match Super Match 90...
Page 92: ...Super Match 91...
Page 93: ...Super Match Super Match 92...
Page 94: ...Super Match Items to Be Checked 93...
Page 95: ...Super Match Super Match 94...
Page 96: ...Super Match 95...
Page 99: ...Super Match Super Match 98...
Page 100: ...Super Match 99...
Page 101: ...Super Match F 100...
Page 102: ...Super Match 101...
Page 103: ...Super Match 102...
Page 106: ...Super Match 105...
Page 107: ...Super Match 106...
Page 110: ...Super Match PCB 0151800175 AD09 24SS1ERA N P AD12MS1ERA AD18MS1ERA AD24MS2ERA 109...
Page 119: ...Super Match Power module 0150400643A 3U24GS2ERA Power module 0150400643B 3U19FS2ERA 118...
Page 120: ...Super Match Filter board 0150400699 3U19FS1ERA 3U24GS2ERA 4U30HS1ERA 5U34HS1ERA 119...
Page 177: ...Piping diagrams Domestic air conditioner 5 Pinping diagrams 176...
Page 180: ...Connector Wiring diagrams Domestic air conditioner 179...
Page 232: ...Piping diagrams Domestic air conditioner 5 Pinping diagrams 231...
Page 235: ...Connector Wiring diagrams Domestic air conditioner 234...
Page 287: ...Piping diagrams Domestic air conditioner 5 Pinping diagrams 286...
Page 310: ...Seivice diagnosis Domestic air conditioner 9 Dimensional drawings 10 Center of gravity 309...
Page 339: ...Piping diagrams Domestic air conditioner 5 Pinping diagrams 338...
Page 391: ...Piping diagrams Domestic air conditioner 5 Pinping diagrams 390...
Page 443: ...Piping diagrams Domestic air conditioner 5 Pinping diagrams 442...