background image

7

Installation

Pressure relief vent

Fig.4 S

 

ketch map of   

 

Safety Valve 

please see Fig.1- Fig.2.
Connection and Use of Safety Valve

when 

the tempreture rise, a little water will drip 
from the safety valve pressure relief vent 
due to normal expansion. The vent shall 
always keep open to the air. Avoid being 
blocked.   
Note: If your water heater is not installed in 
a   b a t h r o o m  w i t h   s e w a g e  d r a i n ,   i t  i s  
suggested you connect a drain hose 
(separately sold) to the safety valve. 
Connect one end of the hose to the safety 
valve vent and the other end to the sewage 
drain. The hose can be cut short or 
extended as necessary. The hose shall be 
installed as inclined downward. 
Connection and Use of tempreture and 
pressure valve:fix the tempreture and 
p r e s s u r e   v a l v e  o n   t h e  t e e   j o i n t  o f  
circulatingentrance of water-storing,please 
see Fig.1-Fig.2.when the tempreture rise, a 
little water will drip from the safety valve 
p r e s s u r e   r e l i e f  v e n t   d u e  t o   n o r m a l   
expansion. 

Introduction of indication board

The vent shall always keep open to the air. Avoid being blocked.  
Note: Forbid you lift the Pressure relief vent artificially,or the reault is serious, 
and you must connect a drain hose (separately sold) to the tenpreture and 
pressure valve. Connect one end of the hose to the tenpreture and pressure 
valve vent and the other end to the sewage drain. The hose can be cut short 
or extended as necessary. The hose shall be installed as inclined downward. 
Note: the mixing valve is separately sold,you can get it from the local haier 
service,and contact the appointed professional serving personnel for 
installing and service.

To fill water into the system

To open water-exiting valve of hot water and to fill water into the whole 
System (water-storing tank. collector equipment and system pipeline) 
Through cold water opening of tap water. To close water exiting valve of hot 
water until the air is exhausted and water flows out continually. Meanwhile, to 
observe whether the system leaks and to keep the cold water entrance open 
in the process of use.

 

8

Introduction of indication board

L1--L4  respectively represent the four 
modes of the system working, among  
which  L2--L4 is double colour , L5--L6  
r e s p e c t i v e l y   r e p r e s e n t     t h e  

For details, see the following:
L1(green)---when the green point in the 
icon is on, it tells that the system is in  
the  solar energy heating mode.
L2(Double color)---when the green 
point in the icon is on, it tells that the 
system is in the simultaneous heating. 
When the red light is glistening, it tells 
that  the system in electrical heating 
and when it reaches the mounted 
temperature, it will automatically leap 
to the solar energy heating mode.

Temperature of  some part of  the  
system  working.

L3(Double color)---when the green point in the icon is on, it tells that the 
system is in the preset heating mode. When the red light is glistening, it tells 
that the system in electrical heating and when it reaches the mounted  
temperature, the green point will be on constantly.
L4(Double color)--- when the green point in the icon is on, it tells that the 
system is in the intellectual heating mode. When the red light is glistening, it 
tells that the system in electrical heating and when it reaches the mounted 
temperature, the green point will be on   constantly.
L5(Yellow)---when the character is on, it tells that the present indication 
temperature is water temperature of water-string tank.
L6(Red)--- when the character is on, it tells that the present indication 
temperature is the  water-exiting temperature of collector equipment.

L1

L1 L2

L2 L3

L3 L4

L4

L5

L5 L6

L6

SET

REG

ON/OFF

MODE

T-DISP

WT

  

HC

SOL H

PRE

INT-H

Temperature Display of 
the tank or collecter

Clock display and set

Figure 6  Indication board

Pressure handle 

Pressure relief vent

Fig.5 S

 

ketch map of tempreture   

 

 And pressure valve 

Introduction of indication board

Use methed

Use methed

For the first use after installation, due to there's no water within the tank, first 
the cold water inlet valve and mixing valve must be opened. Close the mixing 
valve when water flows out continuously from the showerhead or other outlets 
(the tank is full). Check connections are free of water leakage, and insert the 
power plug. 

1. introduction of basic working mode

A.Solar energy heating: this function adopts the temperature difference 

between water-exiting temperature of collector equipment and that of water-

Summary of Contents for Sea Elephant King BRF1-100W

Page 1: ...0500206 Group Qingdao Economic and Technical Development Zone Haier Water Heater Co Ltd website www haier com Solar Water Heater Sincerity For Ever Please read this manual carefully before use Please keep this manual for future reference User s Manual PJF1 80 100W BRF1 80 100W ...

Page 2: ...ment of products Haier water heater you purchase might not consist with the figures in the instruction for which we apologize here to you Haier Correct Disposal of this product This marking indicates that this product shoud not be disposed with other househoud wastes To prevent possible harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to ptomote the s...

Page 3: ...unction Is the sensor of collector damaged Is it connected well with power supply board Is the sensor of storing tank damaged Is it connected well with power supply board Whether the circuit is frozen to jam or whether it leaks Whether tap water pressure is too large over 0 7MPa Check Check and clean Readjust Contact repair section Heat continually Contact repair section Check Contact repair secti...

Page 4: ...s not to burn the pipe as the sun high tempreture In order to make the emptying process convenient you are suggested to purchase water releasing pipe otherwise sold in installment 9 When the system runs continually over one month you are suggested to check regularly whether the deviation of the clock is large so as to adjust the clock promptly and ensure that the preset and intellectual heating mo...

Page 5: ...king mode is selected can the corresponding set content be carried out 1 To avoid that water spurts out to the pump and the electrical enclosure of water storing tank 2 To check the functioning of the system regularly and to check whether the computer board works normally 3 In order to ensure excellent running of solar water heater you are suggested to keep the controller electrified constantly an...

Page 6: ...e heating temperature and temperature difference value of water pump running The number tube in the set parameter indicates glisteningly To press the adjusting Key to adjust numbers when set the parameter up to the highest press the setting key again the number will increase progressivelyfrom the minimal number to continually press more than one second the adjusted parameter will increase progress...

Page 7: ...ipelines must use specially designed materials by our company ollector equipment should be installed facing south Evacuating opening of the system safety valve should be connected to the release opening of sewage All parts of the whole system are not allowed to be disconnected personally otherwise results should be burdened personally C Particular warning Particular warning Particular warning Atte...

Page 8: ...ad according to the preset 65 before the first heating period arrives the second day In cases when the machine is turned on press the mode key continually to enter intellectual heating mode The green point in the working indication icon is on When the electrical heating starts the red point in the icon glistens And when the electrical heating is over the green point is constantly on Press the sett...

Page 9: ...methed storing tank to control the running of water pump It transfers solar energy absorbed by collector equipment to hot water in water storing tank for storage in cases when the machine is turned on press the mode key to enter the solar energy heating mode Note the first time the system is electrified this mode can be entered The green point is in the working indication icon is on in the solar e...

Page 10: ... respectively represent the four modes of the system working among which L2 L4 is double colour L5 L6 r e s p e c t i v e l y r e p r e s e n t t h e For details see the following L1 green when the green point in the icon is on it tells that the system is in the solar energy heating mode L2 Double color when the green point in the icon is on it tells that the system is in the simultaneous heating ...