background image

5

10

Attentions in installment

Electric controller 

 should be far from strong interfering sources.

Tne-way pipeline between water-storing tank and collector equipment must 
be less than 10 meters.
Sensor of collector equipment should be installed at the water  exiting
 Opening.
The exhaust valve should be installed vertically at the water exiting opening
of collector equipment and its position in the pipeline should be kept the 
highest. To screw loosely the exhaust cap after installment to make it 
exhaust freely.
Pay attention the crossing corner of water entering and exiting opening 
should be connected and the bottom one is for water-entering and the top 
one is for water exiting in the installment of collector equipment with flat 
board

.

Installation

Installment of solar water heater is composed by the following parts: 
installment of collector equipment, installment of water-storing tank and 
installment of water pump. Installment of each part should be completed by 
the professional installing personnel appointed by our company in order to 
ensure good functioning of the system.

Installment of collector equipment

Collector equipment of solar water heater is installed with the method of 
oblique top. collector equipment is placed on the southern rooftop of the 
house so as to ensure that the equipment faces south and there is no shelter 
ahead. All the four corners of each collector equipment are linked perfectly 
with steel wire rope. the other end of the steel wire rope is fixed under eaves 
or on the wallwith a expanding bolt. Pay attention that the steel wire rope is 
strained and the expanding bolt is beaten firmly. Take the installment of solar 
water heater of PJF1-80/100W as an example. For the sketch map of 
installment, please see Fig.3.

Expanding bolt

Steel wire rope

Collector

Fig.3  Installment sketch map of  PJF1-80/100W 

Use methed

      then the system will delay at most half an hour for heating.
D. Intellectual heating: this function automatically classifies and analyzes the 

latest seven-day bathing regularity and memorizes the period of time that 
customers have a bath most frequently within the seven days. And it then 
heats ahead according to the preset 65

 before the first heating period 

arrives the second day. In cases when  the machine is turned on, press the 
mode key continually to enter intellectual heating mode. The green point in 
the working indication icon is on. When the electrical heating starts, the red 
point in the icon glistens. And when the electrical heating is over, the green 
point is constantly on. Press the setting mode and you can set the heating 
temperature, whose scope is 30

-75

. Note: in this mode, the solar energy 

heating is not concerned.

2. Introduction of other functions

A. The system has a function of electricity-loss memory and that of automat -ic 

starting when electrified.

B. High temperature protection: in the process of the water pump running, when 

the water temperature of water-storing tank exceeds the high-temperature 
protection temperature (85

) set by the system, the water pump will 

automatically stop running and will display the malfunction code E2.

C. Low temperature protection: when the water exiting temperature is lower than 

the low temperature protection temperature (4

) set by the system, the water 

pump will automatically start running at full speed. And when the temperature 
rises to 7

, the water pump will stop running.

D. Malfunction protection: this system has circuit malfunction alarm (E1), high 

temperature alarm (E2), sensor malfunction alarm of collector equipment (E3), 
sensor malfunction alarm of water-storing tank (E4), as well as pipeline 
leakage and water pump empty running alarm (E5), etc. When these 
problems happen, the system will display malfunction code E1~E5. The 
above malfunction protection is non-restorable and therefore, the system can 
only normally run after malfunction is eliminated and the electricity is re-
connected. 

3. Interface indication and instruction for operation

 After the solar water heater center is installed, to confirm that the water-

storing tank is full with water and to check that each pipeline is connected 
properly and not leaking. To check that the power supply of the water-storing 
tank corresponds to the requirements and then to connect power supply.

4. Instruction for controller setting 

A.Turning on/ turning off: the system is turned on directly and automatically 

enters the working mode and conditions before power supply is cut off. The 
first tacitly approved working mode of the system is the solar energy mode. 
The four-number tube of the indication screen displays the clock. The five-

Summary of Contents for Sea Elephant King BRF1-100W

Page 1: ...0500206 Group Qingdao Economic and Technical Development Zone Haier Water Heater Co Ltd website www haier com Solar Water Heater Sincerity For Ever Please read this manual carefully before use Please keep this manual for future reference User s Manual PJF1 80 100W BRF1 80 100W ...

Page 2: ...ment of products Haier water heater you purchase might not consist with the figures in the instruction for which we apologize here to you Haier Correct Disposal of this product This marking indicates that this product shoud not be disposed with other househoud wastes To prevent possible harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to ptomote the s...

Page 3: ...unction Is the sensor of collector damaged Is it connected well with power supply board Is the sensor of storing tank damaged Is it connected well with power supply board Whether the circuit is frozen to jam or whether it leaks Whether tap water pressure is too large over 0 7MPa Check Check and clean Readjust Contact repair section Heat continually Contact repair section Check Contact repair secti...

Page 4: ...s not to burn the pipe as the sun high tempreture In order to make the emptying process convenient you are suggested to purchase water releasing pipe otherwise sold in installment 9 When the system runs continually over one month you are suggested to check regularly whether the deviation of the clock is large so as to adjust the clock promptly and ensure that the preset and intellectual heating mo...

Page 5: ...king mode is selected can the corresponding set content be carried out 1 To avoid that water spurts out to the pump and the electrical enclosure of water storing tank 2 To check the functioning of the system regularly and to check whether the computer board works normally 3 In order to ensure excellent running of solar water heater you are suggested to keep the controller electrified constantly an...

Page 6: ...e heating temperature and temperature difference value of water pump running The number tube in the set parameter indicates glisteningly To press the adjusting Key to adjust numbers when set the parameter up to the highest press the setting key again the number will increase progressivelyfrom the minimal number to continually press more than one second the adjusted parameter will increase progress...

Page 7: ...ipelines must use specially designed materials by our company ollector equipment should be installed facing south Evacuating opening of the system safety valve should be connected to the release opening of sewage All parts of the whole system are not allowed to be disconnected personally otherwise results should be burdened personally C Particular warning Particular warning Particular warning Atte...

Page 8: ...ad according to the preset 65 before the first heating period arrives the second day In cases when the machine is turned on press the mode key continually to enter intellectual heating mode The green point in the working indication icon is on When the electrical heating starts the red point in the icon glistens And when the electrical heating is over the green point is constantly on Press the sett...

Page 9: ...methed storing tank to control the running of water pump It transfers solar energy absorbed by collector equipment to hot water in water storing tank for storage in cases when the machine is turned on press the mode key to enter the solar energy heating mode Note the first time the system is electrified this mode can be entered The green point is in the working indication icon is on in the solar e...

Page 10: ... respectively represent the four modes of the system working among which L2 L4 is double colour L5 L6 r e s p e c t i v e l y r e p r e s e n t t h e For details see the following L1 green when the green point in the icon is on it tells that the system is in the solar energy heating mode L2 Double color when the green point in the icon is on it tells that the system is in the simultaneous heating ...

Reviews: