background image

1

1.Comfortably-off home water heater:

Collector equipment is aslant installed  on the rooftop and perfectly consists 
with architectures around, which corresponds to the architectural standard 
fashion nowadays.

2.Heat tube coupling is efficient and reliable:

Heat tube coupling is fast and conductive. Vacuum tube of collector equipment 
is without water and dirt, freeze-proof, high endurance, efficient and secure.

3.Selective coat endothermic system

The endothermic system adopts the latest international high-tech and absorbs 
coats selectively. It is characterized by high absorbing capacity and low reverse 
shape.

4.Hot water system of enduring pressure:

A single machine can use the full system of enduring pressure in more than one 
way. Water is supplied in more than one line. There exists a large water stream, 
comfortable water supply and convenient water temperature. System 
functioning is reliable and can be used under all whether conditions.

5

.Humanity design:

Four special working modes are designed to supply water under different 
season climate environments.To automatically adjust linearly the circulating 
speed of water pump according to temperature difference. To save energy and 
to extend longevity of water pump. To ensure there exists the water temperature 
indication. To protect with low and high temperatures, and to use securely and 
conveniently.

14

Electric circuit diagram  

Notes for  usage

  water system, to adjust the the mixing valve on the hot water place, then to 

open the decompression handle of safety valve  and to empty the system.In 
order to make the emptying process convenient, you are suggested to 
purchase water releasing pipe (otherwise sold)in installment.

8.In summer when water heater is not used for long, please close the water-inlet 

valve so as to avoid the suddenness occur, at the same time empty the system. 
Before empty the system, please use hardboard or other same material to 
shade the collector fully, after empty the system,you had better tear down the 
whole circulating pipe so as not to burn the pipe as the sun high tempreture.In 
order to make the emptying process convenient, you are suggested to 
purchase water releasing pipe (otherwise sold)in installment.

9.When the system runs continually over one month, you are suggested to 

check regularly whether the deviation of the clock is large so as to adjust the 
clock promptly and ensure that the preset and intellectual heating modes 
operate normally.

10.In cases when the power supply line of the appliance is damaged, it is the 

personnel of after service who change that for specially designed lines 
(provided by the manufacturer).

11.In cases when the temperature of water-storing tank exceeds 85

, and the 

electrical enclosure indicates E2, you should cut off power supply and 
release then you are suggested to exhaust air that may remain in the pipe, 
during which there should not be smoking or other flame nearby the open 
valve. Meanwhile, you should carefully check whether each part of water 
heater is in good order and then you can use it after confirming that the inner 
container is full with water.

12.The temperature difference for running of circulating water pump suggests 

that the temperature should be chosen as 15 

 in seasons when the 

sunshine is strong(eg, summer), and 10

in seasons when the sunshine is 

weak (eg, winter).

13.When water heater is not used for long and you use it again, to avoid 

occurrence of accidents,you shoud exhaust the system, and the system must 
be full of water before usage,let the gas which lie in the pipe out,meanwhile, 
make sure there is no smoke, fire or other appliances near when you open 
the valve,.the exhausting way: open the hot water outlet  and cold water inlet  
valve, when the water come out sustaining after exhausting all the gas, then 
close the hot water outlet valve.  you had better operation the valve in the low 
tempreture,such as wee hours or night, or the life of the system will be 
influenced. to check  all the parts of the system in good condition, and make 
sure the tank full of water, then you can use it.  

C o n t r o l l e r
Display Board

L:
N:
E:  
K1

K2

R

EH:H
MT:High 
RT1:T
RT2:C

  Brown  Wire

  Blue  Wire 

YelloW/Green  Wire 

elay

eating Element

Temperature Limiter

ank Temperature Sensor

ollector Temperature Sensor

RT1

RT2

K1

K2

Pump

E

L

N

C o n t r o l l e r
Wire Board

le

a

k

a

g

e

 I

n

s

_

P

e

c

tio

n

 L

o

o

p

Summary of Contents for Sea Elephant King BRF1-100W

Page 1: ...0500206 Group Qingdao Economic and Technical Development Zone Haier Water Heater Co Ltd website www haier com Solar Water Heater Sincerity For Ever Please read this manual carefully before use Please keep this manual for future reference User s Manual PJF1 80 100W BRF1 80 100W ...

Page 2: ...ment of products Haier water heater you purchase might not consist with the figures in the instruction for which we apologize here to you Haier Correct Disposal of this product This marking indicates that this product shoud not be disposed with other househoud wastes To prevent possible harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to ptomote the s...

Page 3: ...unction Is the sensor of collector damaged Is it connected well with power supply board Is the sensor of storing tank damaged Is it connected well with power supply board Whether the circuit is frozen to jam or whether it leaks Whether tap water pressure is too large over 0 7MPa Check Check and clean Readjust Contact repair section Heat continually Contact repair section Check Contact repair secti...

Page 4: ...s not to burn the pipe as the sun high tempreture In order to make the emptying process convenient you are suggested to purchase water releasing pipe otherwise sold in installment 9 When the system runs continually over one month you are suggested to check regularly whether the deviation of the clock is large so as to adjust the clock promptly and ensure that the preset and intellectual heating mo...

Page 5: ...king mode is selected can the corresponding set content be carried out 1 To avoid that water spurts out to the pump and the electrical enclosure of water storing tank 2 To check the functioning of the system regularly and to check whether the computer board works normally 3 In order to ensure excellent running of solar water heater you are suggested to keep the controller electrified constantly an...

Page 6: ...e heating temperature and temperature difference value of water pump running The number tube in the set parameter indicates glisteningly To press the adjusting Key to adjust numbers when set the parameter up to the highest press the setting key again the number will increase progressivelyfrom the minimal number to continually press more than one second the adjusted parameter will increase progress...

Page 7: ...ipelines must use specially designed materials by our company ollector equipment should be installed facing south Evacuating opening of the system safety valve should be connected to the release opening of sewage All parts of the whole system are not allowed to be disconnected personally otherwise results should be burdened personally C Particular warning Particular warning Particular warning Atte...

Page 8: ...ad according to the preset 65 before the first heating period arrives the second day In cases when the machine is turned on press the mode key continually to enter intellectual heating mode The green point in the working indication icon is on When the electrical heating starts the red point in the icon glistens And when the electrical heating is over the green point is constantly on Press the sett...

Page 9: ...methed storing tank to control the running of water pump It transfers solar energy absorbed by collector equipment to hot water in water storing tank for storage in cases when the machine is turned on press the mode key to enter the solar energy heating mode Note the first time the system is electrified this mode can be entered The green point is in the working indication icon is on in the solar e...

Page 10: ... respectively represent the four modes of the system working among which L2 L4 is double colour L5 L6 r e s p e c t i v e l y r e p r e s e n t t h e For details see the following L1 green when the green point in the icon is on it tells that the system is in the solar energy heating mode L2 Double color when the green point in the icon is on it tells that the system is in the simultaneous heating ...