background image

2

HSU-12HB03/R2(DB)

Fixing of outdoor unit

Fix the unit to concrete or block with bolts(   10mm) and nuts firmly and horizontally.

When fitting the unit to wall surface, roof or rooftop, fix a supporter surely with nails
or wires in consideration of earthquake and strong wind.

If vibration may affect the house, fix the unit by attaching a vibration-proof mat.

Floor fixing dimensions
of the outdoor unit
(Unit:mm)

Indoor Unit

Selection of Installation Place

Outdoor Unit

Place, robust not causing vibration, where the body can be supported
sufficiently.
Place, not affected by heat or steam generated in the vicinity, where
inlet and outlet of the unit are not disturbed.
Place, possible to drain easily, where piping can be connected with the
outdoor unit.
Place, where cold air can be spread in a room entirely.
Place, nearby a power receptacle, with enough space around. (Refer
to drawings).
Place where the distance of more than lm from televisions, radios,
wireless apparatuses and fluorescent lamps can be left.
In the case of fixing the remote controller on a wall, place where the
indoor unit can receive signals when the fluorescent lamps in the room
are lightened.

Place, which is less affected by rain or direct sunlight and is
sufficiently ventilated.
Place, possible to bear the unit, where vibration and noise are
not increased.
Place, where discharged wind and noise do not cause a
nuisance to the neighbors.
Place, where a distance marked       is available as illustrated
in the above figure.

Power Source

Before inserting power plug into receptacle, check the voltage without fail. The power source is the same as the corresponding name plate.

Install an exclusive branch circuit of the power.

A receptacle shall be set up in a distance where the power cable can be reached. Do not extend the cable by cutting it.

Selection of pipe

To this unit, both liquid and gas pipes shall be insulated

as they become low temperature in operation.

Use optional parts for piping set or pipes covered with

equivalent insulation material.

The thickness of the pipe must be 0.8mm at least.

Liquid pipe

Gas pipe

6.35mm(1/4")

9.52mm(3/8")

Floor fixing dimensions
of the outdoor unit
(Unit:mm)

HSU-22H03/R2(DB)

6.35mm(1/4")

12.7mm(1/2")

HSU-18H03/R2(DB)

HSU-09H03/R2(DB)

HSU-12H03/R2(DB)

HSU-12HB03/R2(DB)

HSU-12H03/R2(DB)
HSU-18H03/R2(DB)

HSU-22H03/R2(DB)

HSU-09H03/R2(DB)

HSU-09HA103/R2(DB)

HSU-22HA103/R2(DB)

HSU-18HA103/R2(DB)

HSU-22HA103/R2(DB)

HSU-18HA103/R2(DB)

HSU-12HA103/R2(DB)

HSU-12HA103/R2(DB)

HSU-09HA103/R2(DB)

583

113.5

113.5

319.5

Summary of Contents for HSU-09HA103-R2

Page 1: ...iping Mark Parts name Non adhesive tape Adhesive tape Saddle L S with screws Connecting electric cable for indoor and outdoor Drain hose Heating insulating material Piping hole cover No Accessory part...

Page 2: ...lightened Place which is less affected by rain or direct sunlight and is sufficiently ventilated Place possible to bear the unit where vibration and noise are not increased Place where discharged win...

Page 3: ...al it off with putty after installation Section of wall hole Piping hole pipe Outdoor side Thickness of wall Indoor side Wall hole 60mm Indoor unit 1 Fitting of the Mounting Plate and Positioning of t...

Page 4: ...rain hose must be bound with refrigerant piping by protecting tape Cut away with a nipper the lid for piping according to the piping direction and then bend the pipe according to the position of wall...

Page 5: ...not correct proper operation can not be carried out and will cause defect 1 If the supply cord is damaged it must be replaced by the manufacturer or its service agent or a similar qualified person The...

Page 6: ...standard pipe length is 5m If it is over 5m the function of the unit will be affected If the pipe has to be lengthened the refrigerant should be charged according to 20 g m But the charge of refriger...

Page 7: ...akage turn the service port s cap the valve rod s cap for 2 way valve and 3 way s a little more than the point where the torque increases suddenly After attaching the each caps check the gas leakage a...

Page 8: ...arried out Please install the drain hose so as to be downward slope without fail Please don t do the drainage as shown below Please pour water in the drain pan of the indoor unit and confirm that drai...

Reviews: