background image

Indoor unit

3.Installation of the Indoor Unit

Drawing of pipe

Rear piping

Left Left-rear piping

Draw pipes and the drain hose, then fasten them with the adhesive tape

In case of left side piping, cut away, with a nipper, the lid for left piping.

In case of left-rear piping, bend the pipes according to the piping direction to the mark of hole for left-rear

piping which is marked on heat insulation materials.

1. Insert the drain hose into the dent of heat insulation materials of indoor unit.

2. Insert the indoor/outdoor electric cable from backside of indoor unit, and pull it out on the front side, then

    connect them.

3. Coat the flaring seal face with refrigerant oil and connect pipes.

    Cover the connection part with heat insulation materials closely, and make sure fixing with adhesive tape

Other direction piping

Indoor/outdoor electric cable and drain hose must be bound with refrigerant piping by protecting tape.

Cut away, with a nipper, the lid for piping according to the piping direction and then bend the pipe according

to the position of wall hole. When bending, be careful not to crash pipes.

Connect beforehand the indoor/outdoor electric cable, and then pull out the connected to the heat insulation

of connecting part specially.

Fixing the indoor unit body

Hang surely the unit body onto the upper notches of the

mounting plate. Move the body from side to side to verify

its secure fixing.

In order to fix the body onto the mounting plate,hold up

the body aslant from the underside and then put it down

perpendicularly.

Lid for right piping

Lid for under piping pipe

Lid for left piping

Heat insulation
material

Drain hose

Piping

Indoor/outdoor
electric cable

Fix with adhesive tape

Pipe supporting plate

4.Connecting the indoor/outdoor Electric Cable

Removing the wiring cover

Remove terminal cover at right bottom corner of indoor unit, then
take off wiring cover by removing its screws.

Summary of Contents for HSU-09HA103-R2

Page 1: ...iping Mark Parts name Non adhesive tape Adhesive tape Saddle L S with screws Connecting electric cable for indoor and outdoor Drain hose Heating insulating material Piping hole cover No Accessory part...

Page 2: ...lightened Place which is less affected by rain or direct sunlight and is sufficiently ventilated Place possible to bear the unit where vibration and noise are not increased Place where discharged win...

Page 3: ...al it off with putty after installation Section of wall hole Piping hole pipe Outdoor side Thickness of wall Indoor side Wall hole 60mm Indoor unit 1 Fitting of the Mounting Plate and Positioning of t...

Page 4: ...rain hose must be bound with refrigerant piping by protecting tape Cut away with a nipper the lid for piping according to the piping direction and then bend the pipe according to the position of wall...

Page 5: ...not correct proper operation can not be carried out and will cause defect 1 If the supply cord is damaged it must be replaced by the manufacturer or its service agent or a similar qualified person The...

Page 6: ...standard pipe length is 5m If it is over 5m the function of the unit will be affected If the pipe has to be lengthened the refrigerant should be charged according to 20 g m But the charge of refriger...

Page 7: ...akage turn the service port s cap the valve rod s cap for 2 way valve and 3 way s a little more than the point where the torque increases suddenly After attaching the each caps check the gas leakage a...

Page 8: ...arried out Please install the drain hose so as to be downward slope without fail Please don t do the drainage as shown below Please pour water in the drain pan of the indoor unit and confirm that drai...

Reviews: