Technical specifications
9
Model
HP200M1-U1
HP250M1-U1
Tank
Total water capacity
195L
246L
Rated voltage/ frequency
220-240V/50Hz
220-240V/50Hz
Tank max pressure
700kPa
700kPa
Corrosion protection
Magnesium rod
Magnesium rod
Waterproof grade
IPX4
IPX4
Performance (20°C/15°C Ambient air temperature, 15°C -55°C water temperature)
COP*@ 20°C/15°C
4.49
4.48
Power input of electric element
1500W
1500W
Rated power input of heat pump
430W
430W
Maximum power input of heat pump
750W
750W
Maximum power input
2250W
2250W
Average heating capacity by heat pump
2000W
2000W
Heating water capacity
42L / h
42L / h
Heating up time (15
℃
-55
℃
)
4.6h
5.8h
Default temperature setting
60°C
60°C
Temperature setting range- with heater
35°C – 75°C
35°C – 75°C
Max temperature of the heat pump only
65°C
65°C
Max working pressure of refrigerant
1.0/3.3MPa
1.0/3.3MPa
Refrigerant type / weight
R290/0.34kg
R290/0.34kg
Sound pressure level *@ 1m
43dB(A)
43dB(A)
Ambient temperature for heat pump
and element
-7~45°C
-7~45°C
Ambient temperature of heat pump
-7~45°C
-7~45°C
Dimension and connections
Water inlet and outlet connection
Rp ¾”
Rp ¾”
TPR valve connection
Rp ¾”
Rp ¾”
Drain & Water inlet connection
Rp ¾”
Rp ¾”
Product Dimensions
600*630*1658mm
600*630*1951mm
Packing dimension with pallet
736*695*1940mm
736*695*2250mm
Net/Gross weight
91/116kg
106/128kg
Filled weight of the appliance
286kg
352kg
*
The COP was measured under test conditions with an ambient air temperature of 20
˚
C/15
˚
C
(Dry Bulb/Wet Bulb) and heating of the water from 15
˚
C to 55
˚
C during water heater operation.
*
The noise level was measured at 1 m from the water heater during a Noise Test conducted to
Standard GB/T 23137 in a hemi-anechoic chamber within a laboratory.