![Haier HP200M1-U1 Operation And Installation Manual Download Page 17](http://html1.mh-extra.com/html/haier/hp200m1-u1/hp200m1-u1_operation-and-installation-manual_3549135017.webp)
Installation instructions
17
CAUTION:
In order to avoid inadvertent resetting of the thermal cut-out, this
appliance must not be supplied through an external switching device, such as
a timer, or connected to a circuit that is regularly switched on and
off by the
utility (off-peak electrical line).
Electrical Safety Requirements
1.
The installation, service or repair of the electrical components of this
appliance must be completed:
a. by licensed trades people.
b. in accordance with all local codes and regulations and
standards AS/NZS 3000.
2.
The surrounding conditions (ambient temperature, direct sunlight and
rainwater) shall be considered during electrical wiring, with
effective
protective measures taken to suit the environment.
3.
Materials that are certified to local standards must be used in the
installation of this appliance.
4.
The appliance must be reliably earthed.
5.
This appliance must be connected to a dedicated circuit. This circuit
must be fitted with a circuit breaker that is no greater than 20 A. It is
recommended that a residual current device (RCD) is also fitted.
6.
The circuit to the appliance should be a minimum of 2.5mm² 2-core
and earth.
Electrical installation
Summary of Contents for HP200M1-U1
Page 23: ...Operating functions 23 ...