![Haier HP200M1-U1 Operation And Installation Manual Download Page 25](http://html1.mh-extra.com/html/haier/hp200m1-u1/hp200m1-u1_operation-and-installation-manual_3549135025.webp)
25
Installation and maintenance of the appliance must be undertaken by a
qualified
professional.
Before working on the appliance, shut down the machine and isolate the power
supply at the switch.
Do not touch with wet hands.
Maintenance operations are important to guarantee optimal performance
and extend the life of the appliance.
-
The evaporator
fins are sharp and
are a potential injury risk.
-Avoid damaging the evaporator
fins as this can affect the performance of the
appliance.
Checking and maintenance
Checking the PTR valve
-
Operate the PTR valve at least once every six months to ensure it is functioning
correctly. If the valve fails to release water when the lever is activated, check
for blockages. If none exist, call Haier Customer Care or a qualified
professional to resolve the issue.
Checking the pipework
-
Check the watertightness of the water connections and piping.
Cleaning the fan
-
The fan should be checked for dust annually. If cleaning is required call Haier Customer
Service or a qualified professional.
-
Checking and cleaning the evaporator must be completed by a qualified professional.
-
It is recommended that the evaporator is cleaned every two years.
Clean the evaporator with a soft brush and water if required. Do not use cleaners on the
evaporator
fins.
Checking the condensate drain
-
Check the condensate drain for blockages as they have the potential to flood
the appliance.
Checking the anode
-
Checking and replacing the anode must be
carried out by a qualified professional.
-
To avoid irreversible corrosion of the cylinder,
it is recommended to check the anode every
five years, and replaced if required.
Magnesium anode
Summary of Contents for HP200M1-U1
Page 23: ...Operating functions 23 ...