Haier HP200M1-U1 Operation And Installation Manual Download Page 1

 

 

Heat Pump Water Heater 
Operation and Installation Manual

 

 
 

 

Model

 

 

HP200M1-U1 
HP250M1-U1

 

 
 
 
 

 

 

SAA-230239-EA 

AS/NZS 2712  SMK41331 
AS 3498    WMK26822 

 
 
 
 
 
 
 

Please read this manual carefully prior to the 
installation and use of this appliance.

 

The appearance of the water heater given in 
this manual is for reference only.

 

This product must be installed outdoors.

 

Summary of Contents for HP200M1-U1

Page 1: ...U1 HP250M1 U1 SAA 230239 EA AS NZS 2712 SMK41331 AS 3498 WMK26822 Please read this manual carefully prior to the installation and use of this appliance The appearance of the water heater given in this manual is for reference only This product must be installed outdoors ...

Page 2: ...allation and utilisation of the product 1 This appliance is not intended for use by persons with reduced physical sensory or mental capabilities persons with a lack of experience and knowledge or children under the age of 8 years Persons in this group must be supervised while using the appliance by a person responsible for their safety 2 Children should be supervised to ensure that they do not pla...

Page 3: ...nt R290 used in this product is odorless 4 This product mustbeinstalledoutdoors 5 This product cannot be discarded or scrapped without correct retrieval of the refrigerant a If necessary please contact Haier Customer Service to obtain the correct disposal method 6 The product must not be stored in an area containing an open flame such as an open fire gas appliance or electricheater 7 Before the refr...

Page 4: ...ons The power supply must have a grounding line Ensure an effective ground connection Ground and neutral lines of the power supply must not be connected The ground line shall not be connected to gas or water pipes lightning arresters or telephone lines The water heater must be installed in a location where suitable water drainage is possible The water heater must be installed outside This appliance...

Page 5: ...tall the water heater in strict accordance with these installation instructions If the power cord is damaged it must be replaced by a qualified professional Do not put hands or other items into the air grid This may cause injury or damage to the appliance Risk of damage to the environment This heat pump contains the refrigerant R290 The PTR valve drain must be installed in a continuously downward d...

Page 6: ...llation ensure that the ground wire is disconnected last 8 If a refrigerant leak occurs ventilate the area immediately The refrigerant is flammable so damage or injury is possible if it reaches an open flame 9 Be aware that the refrigerant contained in this appliance does not have an odour 10 Do not accelerate the defrosting process or clean the evaporator when frosted Only a qualified person shou...

Page 7: ...llowable appliance quantity or refrigerant R290 volume that can be transported at any one time Storage requirements 1 As this appliance contains a flammable refrigerant R290 its storage must be in accordance with local regulations 2 The storage should ensure that there is no potential for damage to the appliance Any damage could result in a refrigerant leak Scrapping and recovery requirements 1 Sc...

Page 8: ... fan Powered by electricity the compressor absorbs low temperature and low pressure refrigerant gas from the evaporator It compresses the gas into high temperature and high pressure gas which is passed through the condenser to transfer heat to the water The condensed refrigerant is then throttled and depressurized by the expansion valve It then absorbs heat from the surrounding air via the evapora...

Page 9: ...re of the heat pump only 65 C 65 C Max working pressure of refrigerant 1 0 3 3MPa 1 0 3 3MPa Refrigerant type weight R290 0 34kg R290 0 34kg Sound pressure level 1m 43dB A 43dB A Ambient temperature for heat pump andelement 7 45 C 7 45 C Ambient temperature of heat pump 7 45 C 7 45 C Dimension and connections Water inlet and outlet connection Rp Rp TPR valve connection Rp Rp Drain Water inlet conn...

Page 10: ...components 10 Carton contents Display PTR valve connection Condensation drain Hot water outlet PTR valve connection Cold water Inlet Part name Heat pump water heater TPR valve Instruction manual Quantity 1 1 1 Heatpumplayout ...

Page 11: ...ion valve 7 Four way valve 8 Compressor 9 Evaporator 10 Top cover 11 Support 13 14 Diversion air duct Fan blade S N Description 15 Rear shell 16 Compressor capacitance 17 Thermal cut out 18 Decorative cover 19 Waterproof cover 20 Heating element 21 Sensor pocket 22 Magnesium anode 2 1 3 4 5 16 17 6 7 8 9 12 13 11 14 15 10 18 19 20 23 21 24 22 12 DC motor 23 Communication cable 24 Power cable ...

Page 12: ...te water can be drained freely 3 If installed on a base ensure that this base is level to allow correct drainage via the condensate drain at the rear of the appliance 4 The location or position of the appliance will not create nuisance noise for the homeowners or neighbors especially through proximity to bedrooms 5 Ensure that the location allows condensate and PTR valves to be drained into an are...

Page 13: ...Installation instructions 13 30 PTR valve unit mm Model A B C D HP200M1 U1 630 267 979 1658 HP250M1 U1 630 267 1272 1951 Installation dimensions D C B ...

Page 14: ...liance must be installed in a location where it can be quickly and easily drained and moved to a location with 1000mm clearance above the appliance This is so the anode to be removed for checking and replacing during the 5 yearly service 300mm 100mm Air outlet Display ...

Page 15: ...nce If the supply pressure could exceed 500kPa a pressure limiting valve must be installed on the cold water inlet If a cold water expansion control valve ECV is required by local regulations a valve of a maximum of 600kPa can be fitted The correctly sized pressure limiting valve should also be fitted as per the ECV manufacturers specifications If no ECV is fitted a pressure limiting valve of a ma...

Page 16: ... correctly filled once water flows continuously from this fixture without air bubbles Venting through the PTR could cause premature failure of the valve 10 If there is a risk of freezing hot and cold water pipes connected to the appliance must be insulated with 20mm insulation Failure to adhere to this may result in a voided warranty if damage due to freezing occurs 11 In accordance with safety ru...

Page 17: ... codes and regulations and standards AS NZS 3000 2 The surrounding conditions ambient temperature direct sunlight and rainwater shall be considered during electrical wiring with effective protective measures taken to suit the environment 3 Materials that are certified to local standards must be used in the installation of this appliance 4 The appliance must be reliably earthed 5 This appliance must...

Page 18: ...uld be fitted with three stainless steel straps 25mm wide x 1mm thick These straps should be fitted as per the following instructions Top strap Under the front cover and no more than 100mm from the top the painted cylinder section of the appliance Middle strap Under the front cover at the center of the painted cylinder section of the appliance Bottom strap Below the front cover and no more than 10...

Page 19: ...r lines are correctly insulated Commissioning checklist Wiring diagram R S C K3 Black FAN t t t CN1 K1 K2 L L N L IN N IN N Leakage protection coil GND Capacitor White Compressor Electric heating element Blue Brown Blue Over tempeature thermostart Four way valve White Discharge temperature sensor Defrost temperature sensor Ambient temperature sensor Suction temperature sensor CN12 CN6 CN19 CN17 t ...

Page 20: ...ic defrosting function Thedefrosting mode is automaticallyactivatedifthe outdoor temperature is low and the compressor has run for some time D Overload protection The working load of the compressor will be high in warm ambient air temperatures To meet hot water requirements and to lengthen appliance life this product automatically adjusts the fan speed to ensure reliable operation of the compresso...

Page 21: ...maximum continuous working time canbeadjustedintheinstallersettings ECO off peak mode Prioritizes heatpumpheating via two methods 1 User entered timer settings 2 Communication from power companies Electric heating mode In this mode the backup element is used as the only heat source This function ensures hot watersupply when the heat pump is not working properly Vacation mode Maintains a minimum tem...

Page 22: ...ime Hot water volume display Time of peak off peak hours In Time of peak off peak hours mode the symbol corresponding to the mode is displayed When receiving the signal HC lights up Anti Anti legionella function will be activated every 7 days to heat the tank to 65 C automatically WIFI signal icon Lock screen display icon 1 Enter In the power on state press and hold TIMER BOOST combination key for 6...

Page 23: ...Operating functions 23 ...

Page 24: ...e adjustment range is 5 15 C 9 10 5 15 WIFI connection Your appliance can be connected to your home wireless network and operated remotely using the app Getting started 1 Ensure your home Wi Fi network is turned on 2 Press and hold to enter the distribution network status At this time the WIFI icon will flash If the connection is successful the WIFI icon will always be on If the connection is not ...

Page 25: ...all Haier Customer Care or a qualified professional to resolve the issue Checking the pipework Check the watertightness of thewaterconnections and piping Cleaningthe fan The fan should be checked for dust annually If cleaning is required call Haier Customer Service or a qualified professional Checking and cleaning the evaporator must be completed by a qualified professional It is recommended that ...

Page 26: ...from an unfiltered water source that may be highly conductive or have a high mineral content may void the system warranty The following characteristics should not be exceeded in order for the warranty to be conditions not to be breached Total hardness 200 mg litre or ppm Chloride 250 mg litre or ppm Sodium 150 mg litre or ppm Electrical conductivity 850 μS cm 10 mg litre or ppm Magnesium 600 mg li...

Page 27: ...rexhaust temperature sensor Ifshortcircuitorcircuitbreakoccurs to the sensor E6 Faultoftheairintake temperature sensor Ifshortcircuitorcircuitbreakoccurs to the sensor ED Communication fault Communicationofmaincontrolpanel and display panel is abnormal E7 Pressure switch protection Actionofthepressureswitchatthe exhaust outlet E8 Ambienttemperature protection Ambient or outdoor temperature 7 or 45...

Page 28: ...Paykel Australia Pty Ltd Level 1 1 Eden Park Drive Macquarie Park NSW 2113 Phone Customer Care 1300 729 948 Email customer care haier com au Fisher Paykel Appliances Ltd 78 Springs Road East Tamaki Auckland 2013 Phone Customer Care 0800 424 372 Email customer care haier co nz 0040511380 20230228 V ...