5
iNSTALLATiON iNSTrUCTiONS
Power
OR61S2CEWW
220-240/380-415 V 2N AC 50 Hz 47.6A
OR61S4CEWW
220-240/380-415 V 2N AC 50 Hz 47.6A
OR61S8CEWSW
220-240/380-415 V 2N AC 50 Hz 53.7A
pn 590110A 07.10
F&P Italy pn 0422403
finished size 150x79 mm roll feed label
1 colour Black
Gloss yellow self adhesive roll-feed sticker
OR61 ELECTRICAL CONNECTION: INFORMATION FOR THE INSTALLER
WARNING!
IMPORTANT!
This appliance must be connected to the electrical supply by a suitably registered person.
Connection by an unqualified person can cause a safety hazard.
Before obtaining access to terminals, all supply circuits must be disconnected. Failure to do so may result
in death or electrical shock.
We recommend that the appliance subcircuit is protected by a suitably rated Miniature Circuit Breaker (M.C.B.)
but not connected to a Residual Current Device (R.C.D.) or an Earth Leakage Circuit Breaker (E.L.C.B.).
In NZ, this appliance must be connected to the electrical supply using a cable fitted with an appropriately rated plug. The plug
must be compatible with the socket-outlet fitted to the final subcircuit in the fixed wiring that is intended to supply the appliance.
The supply cable should be at least equivalent to an ordinary PVC sheathed and insulated, min. 4 mm
2
, three-core
(twin and earth), min. 1 m long flexible cable.
FOR SINGLE PHASE CONNECTION:
The supply cable should be at least equivalent to an
ordinary PVC sheathed and insulated, min. 2.5 mm
2
,
four-core, min. 1 m long flexible cable.
Remove for two-phase
connection
If fitted, the bridging link between ‘2’ and ‘3’ should
be removed, as shown. Failure to do this will result
in damage to the appliance.
FOR TWO-PHASE CONNECTION:
Electrical connection
●
●
Some models have two side-mounted power outlets: the power socket on these cookers
are rated at 250V 10A AC only.
●
●
We recommend that the cooker sub circuit is protected by a suitably rated Miniature
Circuit Breaker (M.C.B) but not connected to a Residual Current Device (R.C.D) or an
Earth Leakage Breaker (E.L.C.B). In New Zealand this appliance must be connected to
the electrical supply using a cable fitted with an appropriately rated plug. The plug must
be compatible with the socket-outlet fitted to the final subcircuit in the fixed wiring that
is intended to supply the appliance.
Single phase connection:
●
●
The supply cable should be at least equivalent to an ordinary PVC sheathed and
insulated min. 4 mm
2
, three-core (twin and earth), min. 1 m long flexible cable.
Two-phase connection:
●
●
The supply cable should be at least equivalent to an ordinary PVC sheathed and
insulated, min. 2.5 mm
2
, four-core, min. 1 m long flexible cable. If fitted the bridging link
between 2 and 3 should be removed, as shown. Failure to this will result in damage to
the appliance.
●
●
This appliance must be connected to a circuit which incorporates an isolating switch
providing full disconnection from the power supply.
●
●
If you raised the cooker to align it with the bench, make sure the base of the cooker
cannot slip.
Connecting the cable
1
Remove the cable access cover (lower right hand corner).
2
Provide a minimum of 1 metre of cable.
●
●
For 220-240 single phase operation, connect phase wire to terminal 1
(with links between 1-2 and between 2-3 fitted).
●
●
For 380-415V two phase operation, remove the link between 2-3 and connect phase 1
wire to terminal 1 (with link between 1-2 fitted); then connect phase 2 wire to
terminal 3.
3
Connect neutral wire to terminal 5 (with link between 4-5 fitted).
4
Connect ground wire to
earth terminal
MODEL OR61S2L
,
,
MODEL OR61S2CE
1200W CERAMIC GLASS
1200W CERAMIC GLASS
16 A MAX
The power socket outlets on these cookers are rated at 250V 10A AC only.
1800W CERAMIC GLASS
MODELS OR61S4CE / OR61S8CE
PN 590109B F&P Italy PN 0422401 08.10
.
5
Replace cover; check that no
conductors are trapped by
the wiring cover.
MODEL OR61S2L
,
,
MODEL OR61S2CE
1200W CERAMIC GLASS
1200W CERAMIC GLASS
16 A MAX
The power socket outlets on these cookers are rated at 250V 10A AC only.
1800W CERAMIC GLASS
MODELS OR61S4CE / OR61S8CE
PN 590109B F&P Italy PN 0422401 08.10