Height of rangehood

MINIMUM CLEARANCES

mm

J

Height top of gas cooktop to base of rangehood

min. 650 – max. 700

K

Height of rangehood installation

if ducted through the ceiling

if ducted through the rear

min. 610

min. 990

L

Depth of rangehood installation

533

K

J

L

Summary of Contents for HCH-T895

Page 1: ...Range Hood HCH T895 model ...

Page 2: ......

Page 3: ...hange at any time For current details about model and specification availability in your country please contact your local Haier dealer Introduction 2 Safety and warnings 3 Installation instructions 4 About your rangehood 11 Operating instructions Control panel 12 Cleaning and maintenance 13 Troubleshooting 15 Manufacturer s Warranty 17 ...

Page 4: ......

Page 5: ...2 INTRODUCTION Thank you for purchasing a Haier rangehood This user guide explains the features and functions and will help you get the most out of your rangehood We hope you enjoy your new rangehood ...

Page 6: ......

Page 7: ...d into a hot flue being used to vent appliances burning gas or other fuels Do not flambe directly under the rangehood Children and persons with reduced physical sensory or mental capabilities shall not use the range hood without supervision This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and k...

Page 8: ...ptacle 1 Self tapping screw ST4 x 12 4 Universal ducting hose 180 2 Expansion plug 8 x 40 7 Self tapping screw ST3 x 8 2 Cross recessed pan head screw M4 x 20 8 Mounting screw 5 x 50 7 Rangehood 1 Wall plate 1 T he screws and plugs are to be used in concrete or brick walls only Different fixings will be required for other types of wall construction Range Hood HCH T895 model Haier ...

Page 9: ...STALLATOIN INSTRUCTIONS Namesof principal components Fan Oil Cover Hand tightened nut Inner decorative cover Intake ring Outer decorative cover Top cover Volute Check valve assembly Main housing LED Light 1 ...

Page 10: ...t min 610 max 990 B Overall width of product 895 C Overall depth of product 520 D Height of canopy 80 E Width of flue 375 F Depth of flue 320 G Centre of ducting to left edge of product 370 H Centre of ducting to back edge of product 170 I Outside diameter of check valve assembly 185 IMPORTANT A E F B G C H I A D max min Actual product dimensions may vary by 2 mm ...

Page 11: ...ehood MINIMUM CLEARANCES mm J Height top of gas cooktop to base of rangehood min 650 max 700 K Height of rangehood installation if ducted through the ceiling if ducted through the rear min 610 min 990 L Depth of rangehood installation 533 K J L ...

Page 12: ... prevent hazards such as electric shocks or gas leaks Temporarily mark the height of the bottom of the rangehood and the centre of the cooktop on the wall according to the information given on page 8 2 Install the wall plate Fit the expansion plugs into the holes Secure the wall plate to the wall using the mounting screws 3 Install the decorative cover holder if inner decorative cover extension is...

Page 13: ...9 INSTALLATION INSTRUCTIONS 4 Install the supports Attach the supports to the back of the rangehood as shown in Fig 3 Fig 2 Fig 3 ...

Page 14: ...niversal ducting hose into the recess of the check valve and secure to the check valve assembly with the self tapping screws Connect the other end of the ducting hose to a shared flue or external wall hole venting performance The number of bends should be minimised Flexible ducting should be stretched tight and trimmed to suit the installation 9 Extend the inner decorative cover if inner decorativ...

Page 15: ...se Universal Ducting Hose Net Weight Odour Removal Efficiency Grease Separation Off Power Standby Power Total Pressure Efficiency LED Lamp Technical Data Input Power 3 W Rated Voltage 12 V Cap Type Buckle Size 220 mmX58 mm 219 W 222 W 20m min Rated Voltage 230V Rated Frequency 50 Hz At Air Flow of 7 m min 260 Pa Outer Diameter 180 mm Length 1500 mm 68 dB A 90 2 W 23 ...

Page 16: ... smoke from spilling out from the front end of the range hood so that the protecting user is not harmed by the oil smoke Press this button the hood will connect to electricity When fan is on press this button the hood will enter Delay off mode and turns off in 3 minutes In Delay off mode press this button to turn off the hood Turns the light on or off Lighting switch operates independently Control...

Page 17: ...receptacle as necessary When the oil receptacle reaches the mark it should be removed promptly to avoid overflow Pull the oil receptacle straight out to detach r e v o C l i O e h t m o r f t i Empty the oil receptacle The oil receptacle should be washed in warm water with detergent do not use corrosive chemicals To replace the oil receptacle slide it into the slot on the and ensure it is pushed a...

Page 18: ... the screws holding the main housing cover plate and remove the cover plate Loosen the screws holding the intake ring and remove the intake ring Twist the nut in a clockwise direction to remove the fan Take particular care when cleaning the fan that the clips on the blades are not moved or lost as this will imbalance the fan and cause vibration of the entire rangehood leading to increased noise To...

Page 19: ... out Replace the light please contact the after sales service centre Product vibrates Main unit is not securely fastened to wall Check that the main unit is fastened securely Fan is not well fitted Fit the fan properly Fan is damaged Replace the fan please contact the service centre Hand tightened nut is loose Tighten the hand tightened nut Poor suction Windows and doors are open too wide during u...

Page 20: ...roblem by following the above prompts or one of the situations below occurs please unplug the rangehood straight away and contact our after sales service centre 1 The rangehood runs unevenly when turned on 2 The rangehood makes an unusual noise during operation 3 Strange odours heat or smoke are discovered or other unusual circumstances not mentioned above occur The following phenomenon is not a m...

Page 21: ...en the product is installed outside the Haier Authorised Repairer s normal service area This product has been designed for use in a normal domestic residential environment This product is not designed for commercial use whatsoever Any commercial use by a customer will affect this product s Manufacturer s Warranty Service under this Manufacturer s Warranty must be provided by a Haier Authorised Rep...

Page 22: ...rvice centre be liable for any consequential damages or resulting liability damage or loss arising directly or indirectly out of any defect in the product 11 This warranty is not valid in case of the following events a If the Product has been Installed Serviced Repaired Opened or Tampered by any unauthorised personnel b If defects arise caused by accidents alteration misuse neglect substitution of...