Summary of Contents for ISPIRA IS700 Series

Page 1: ...ER HOMEOWNER USE AND CARE INFORMATION ON PAGES 15 TO 17 READ AND SAVE THESE INSTRUCTIONS Venmar Ventilation ULC 550 Lemire Blvd Drummondville QC J2C 7W9 1 800 567 3855 REGISTER YOUR PRODUCT ONLINE AT www bnv ca For additional information visit www venmar ca 21226 rev 04 INSTALLATION INSTRUCTIONS ...

Page 2: ...ood i e Crêpes Suzette Cherries Jubilee Peppercorn Beef Flambé c Clean ventilating fan frequently Grease should not be allowed to accumulate on fan filters or in exhaust ducts d Use proper pan size Always use cookware appropriate for the size of the surface element 1 For indoor use only 2 For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors 3 To avoid ...

Page 3: ... digital device pursuant to part 15 of the FCC Rules and the Canadian ICES 003 These limits are designed to provide reasonable protection against harmful interference in a residential installation The remote control generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However t...

Page 4: ...nd to install the hood at a minimum distanceof30 abovecookingsurface Amaximum of 36 above cooktop is highly recommended for best capture of cooking impurities Distances over 36 are at the installer and users discretion 10 ft ceilings require 10 ft flue extension part no 19324 sold separately 1 INSTALL DUCTWORK 8 ROUND DUCT ROOF CAP HOOD HH0152A DECORATIVE FLUE 8 ROUND ADAPTER DAMPER 30 TO 36 ABOVE...

Page 5: ...ed locknuts 50 x 10 32 x 1 2 quadrex hex head screws 2 no 8 1 2 low profile Philips screws Parts sold separately Ducts elbows wall and roof caps Optional flue extension for 10 ft ceilings model no 19324 Optionnal remote control model no 21233 Glass panels for IS70036WG model see replacement parts list NOTE During installation protect countertop and or cooktop WARNING When performing installation s...

Page 6: ...s framing between ceiling joists using ceiling mounting bracket dimensions shown at right The framework must be sized to support the total weight of the hood and should not be larger than 9 x 9 HD0432 HOUSE WIRING CEILING JOISTS CROSS FRAMING 2 Finish ceiling surface making sure the ceiling is level in all direction Be sure to mark the location of the ceiling joists and cross framing Bring house w...

Page 7: ...nting plate in such a way that one of the sides without a T will be facing the front of the hood Secure mounting bracket to the ceiling using 8 no 10 x 1 wood screws 2 on each corner Make sure screws are driven into the center of the framing for maximum strength 5 ASSEMBLE ANGLE BRACKETS HD0421 1 Assemble 4 angle brackets to the ceiling mounting bracket using 16 no 10 32 x 1 2 quadrex screws 4 per...

Page 8: ...per flue and use the optional extension flue part no 19324 soldseparately Fouradditional angle brackets and additional mounting hardware are included with the optional extension flue If need be assemble a third set of 4 angle brackets to the second angle bracket set according to the length needed Use 16 no 10 32 x 1 2 quadrex screws and 16 no 10 32 lock nuts 4 at each angle bracket connection 6 RE...

Page 9: ...tuds in appropriate hood holes NOTE Install the glass panel with the control pictograms on the front of the hood 3 While holding glass panel pre tighten the previously removed nuts by hand Ensure glass panel is centered Then using a 3 8 socket tighten nuts completely 4 Repeat the same steps for the second glass panel installation 7 INSTALL GLASS PANELS WG MODEL ONLY HD0568 HD0569 FRONT GLASS PANEL...

Page 10: ...hand corner of blower box 1 to ease wire clamp installation included Install wire clamp and push flap back in place Secure flap to blower box 2 using 1 no 8 x 3 8 quadrex screw NOTE Install wire clamp diagonally as illustrated in image 2 otherwise it will be difficult to tighten it s screws once the blower box is attached to the angle brackets HE0062 ELECTRICAL COMPARTMENT RETAINING SCREW HE0063 2...

Page 11: ...r box using 4 no 8 x 3 8 quadrex screws included Remove tape on damper HJ0067 6 Measure the required length of 8 round metal duct from the adapter damper to the ductwork rough in in the ceiling Connect this section of duct to the adapter damper and seal joint with metal foil duct tape ...

Page 12: ...ont of the hood will be positioned 2 Run house wiring through wire clamp into blower box electrical channel Tighten wire clamp to secure house wiring cable to blower box NOTE The length between the top of the blower box and the bottom of the hood is 12 3 16 3 Slide the upper flue up to the ceiling and secure it to the mounting plate using 2 no 8 x 1 2 quadrex screws 1 NOTE Ensure flue seam is on t...

Page 13: ...s are illustrated at right Make sure that the house wiring goes into the electrical compartment 5 Slide the lower flue down on top of thehoodandsecurefrominsidethe hood using 4 no 8 x 3 8 quadrex screws included 6 Remove protective plastic film from hood and flues HD0426 SCREW LOCATIONS HD0559 SCREW LOCATIONS ELECTRICAL COMPARTMENT ...

Page 14: ...s BLACK to BLACK WHITE to WHITE and GREEN or BARE wire to GREEN ground screw DO NOT FORGET TO CONNECT THE GROUND Reinstall electrical box cover ensuring its 3 tabs are tucked inside the electrical channel 2 Connect blower 11 REINSTALL HYBRID FILTERS CAUTION Remove protective plastic film covering filters before reinstalling them Rest rear filters edge on filter springs in the range hood Tilt up th...

Page 15: ...nse well with clear water 2 or 3 times after cleaning Wipe dry completely You may also use a specialized household stainless steel cleaner Don t Use any steel or stainless steel wool or any other scrapers to remove stubborn dirt Use any harsh or abrasive cleansers Allow dirt to accumulate Let plaster dust or any other construction residues reach the hood During construction renovation cover the ho...

Page 16: ...e in order to clean the glass panel To lock the control interface Press and hold this button for 2 seconds The button will light to its high intensity and flash three times it will then stay on its mid intensity to indicate that the control interface is locked To unlock the control interface Press and hold this button for 2 seconds The button will light to its high intensity and flash 3 times it w...

Page 17: ...d when the lights are on press and maintain the light button for 1 second lights will be turned off NOTE When only the lights are ON to any intensity and no interaction with the hood is detected for a 10 second period the 7 buttons backlighting will fade to its low intensity acting as a night light feature ii When lights are off pressing and holding this button for 1 seconds will switch the backli...

Page 18: ... 3 1 2 YEL BLK BLK WHT WHT WHT RED RED RED BLU WHT ORG BLK WHT BLK WHT RED RED WHT BLK WHT RED GRY BRN BLU WHT ORG BLK BLK BLACK BLU BLUE BRN BROWN GRN GREEN GRY GREY ORG ORANGE RED RED WHT WHITE YEL YELLOW COLOR CODE HE0057A REPLACEMENT PARTS AND REPAIRS In order to ensure your unit remains in good working condition you must use Venmar Ventilation ULC genuine replacement parts only Venmar Ventila...

Page 19: ...ODULE 1 2 9 62053 HYBRID FILTER 15 875 X 14 x 0 5 1 2 10 SV09957XX BACK GLASS PANEL 1 11 08543 8 ROUND ADAPTER DAMPER 1 12 09518 ANGLE BRACKET KIT 4 2 13 19232 INSTALLATION BRACKET 1 14 SV19231 UPPER FLUE COVER 1 15 SV19230 LOWER FLUE COVER 1 21226 INSTALLATION MANUAL 1 09871 PARTS BAG 1 PART NUMBER ACCORDING TO GLASS PANEL COLOR PLEASE CONTACT CUSTOMER SERVICE OR REFER TO WEB SITE ITEM NOT SHOWN ...

Page 20: ...tilation ULC Where applicable in home service will be made available only in areas where a contracted service provider offers service If in home service is not available the product will be repaired or replaced at Venmar Ventilation ULC s discretion by the nearest authorized service provider The unit removal and reinstallation works are under the customer responsibility and Venmar Ventilation ULC ...