background image

 

 

 

Page 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 

 

©® copyright luxair UK Ltd 2014

 

To avoid the risk of accidents 
or damage to this appliance It is 

Essential

 to read these 

Instructions before it is installed 
and used for the first time. 

 

O perating &  I nstallation 
I nstructions: All M odels 

Summary of Contents for CVD Series

Page 1: ...luxair UK Ltd 2014 To avoid the risk of accidents or damage to this appliance It is Essential to read these Instructions before it is installed and used for the first time Operating Installation Instructions All Models ...

Page 2: ...ds STD Models 10 12 Fitting Charcoal Filters 13 14 Installation of Wall Mounted Hoods CVD Models 15 16 Operating Instructions 17 Installation of all Island Hoods 18 20 Changing the Bulbs 21 22 Changing Your light Fittings 23 Problem Solving 24 Cleaning and Care 25 26 Technical Specifications 27 Warranty Form 28 Terms And Conditions 29 31 Contact Us 32 Contents ...

Page 3: ...ll void the warranty Disposal of your old appliance Electrical and electronic appliances often contain materials that if handled or disposed of incorrectly could be potentially hazardous to human health and to the environment They are however essential for the correct functioning of your appliance Please do not therefore dispose of your old appliance with your household waste Please dispose of it ...

Page 4: ...e appliance to the mains supply make sure that the connection details given on the data plate correspond with the on site electricity supply otherwise the appliance could get damaged The appliance could get damaged Consult a qualified electrician if in any doubt The electrical safety of this appliance can only be guaranteed when continuity is complete between the appliance and an effective earthin...

Page 5: ...the motor unit Always switch the cooker hood on when a cooking zone is in use otherwise condensation may collect in the hood which could cause corrosion When cooking with oil or fat chip pans and deep fat fryers etc do not leave the pans unattended Never leave an open grill unattended when grilling Overheated oil and fat can ignite and could set the cooker hood on fire Do not use the cooker hood w...

Page 6: ...oker hood and they have different minimum safety distances to the cooker hood select the greater distance Safety regulations prohibit the fitting of a cooker hood over solid fuel stoves All ducting pipe work and fittings must be of non flammable material These can be obtained from the Luxair web site or from local builders merchants Note All porducts MUST be fitted with a 3amp fuse The appliance m...

Page 7: ... to the outside vent plate unless the motor size exceed 980m3 hr applies to all wall mounted and island models Ducting must be fitted to the out side of the reducer collar and secured with a zip fastener also the d ucting must b e aluminium and conform to fire regulations Kits can be purchased form Luxair s web site The minimum height setting measuring from the underside of the extractor to the to...

Page 8: ...ed air back into the room Failure to do so will result in the hood been noisy and will cause it to vibrate this will also void the warranty if this section is not used when installed in recirculation mode Note that when the hood is not vented to an outside wall charcoal filters ust be used in Conjunction with the above vent system For fitting instructions please see pages ...

Page 9: ...ox 3 Do not remove any of the protective film until installation is complete this will help reduce any accidental damage and help prevent scratching 4 Remove the metal Grease filters immediately after opening packaging and storein a safe place they will not be needed until installation is complete this will also ensure against accidental damage of the filters 5 You must use either a ducting kit or...

Page 10: ...Page 10 2 3 4 6 5 1 Wall Bracket 2 Top Chimney Section with Vents 3 Bottom Chimney Section 4 Reducer 5 Main Body 6 fixing screws Hoods Check List Standard 1 2 3 4 5 6 ...

Page 11: ...l yo u have if yo u are in an y doubt then seek professio nal advice 3 Measure the desired height of yo ur chimney sections Measure the center of the main body section of the hood and then draw a straight vertical line place the metal u shaped bracket at desired height center to your line and secure the bracket to the wall 4 Mark the height and position of your ducting hole this should be a minimu...

Page 12: ... the hood no fixings are required as the grooves secure this part slide the top section into the b ottom section of the chimney taking care not to scratch this as you do so The vented top section can be turned upside down if the hood is ducted outside this will hide the vents that are unnecessary for ducted out use See page 12 for more details on vented or recirculated options 8 Slide the top sect...

Page 13: ...e sid e preventing snagging 3 Offer the filter to the bottom and back the flue section and insert into back L shaped bracket Push the filter into place and secure with the front screw as opposite Please note that the filters are only necessary for hood s that are not vented to an outside wall and must be replaced every 50 hours or two three months ...

Page 14: ... feel the filter sit Twist clockwise until you feel it lock Reverse the process to remove Please note that charcoal filters will need replacing every 2 months or every 50 hours of cooking Failure to replace these filters will result in the warranty being void For Replacement filters please visit our website at www Luxairhoods com ...

Page 15: ...Page 15 Hoods Checklist Curved Glass Straight Glass 1 2 3 4 5 6 1 Wall Bracket 2 Top Chimney Section 3 Bottom Chimney Section 4 Reducer Collar 5 Body Section 6 8mm Safety Glass 7 Fixing Screws ...

Page 16: ... assembled and checked place your glass directly on top of the main body section line up with the screw holes and secure with screws and washers Warning do not over tighten these screws they should be hand tight only Over tightening may cause the glass to break 2 After fitting the glass now fit the two telescopic chimney section please ensure that you do this with care slide the top section up to ...

Page 17: ...ill then turn its self off after 20mins to cancel this simply press the T button again 4 If the light button starts to flash simply press and hold it for 3 seconds to deactivate 5 If The 1 and button is flashing this needs resetting by turning the on then turn the off then hold for 10 seconds I 0 II III Electronic Switches Push Button Switches 1 select speed I to activate your fan then II and so o...

Page 18: ... sure you are center to your hob 2 Make sure that your fixings will hold at least 75kg in weight this must also be flush with the ceiling Drill a 150mm hole in the ceiling and connect your ducting run it to the outside wall this must not exceed 4mtrs in length 3 Pass the ducting hose and electrical cable through the center hole of the Ceiling top inner arm Proceed to secure the arm to your ceiling...

Page 19: ... tighten these screws as you may cause the glass to shatter 5 Insert the top stainless steel chimney section into the bottom stainless steel section take care not to force this as you may cause damage 6 Lift the whole unit up onto the main pre fixed upper inner arm slide it up or down to correct height make sure that you have allowed the minimum height above your hob unit ...

Page 20: ...should now be secure 8 Make all final ducting and electrical connections through the specially cutout hole Test that all ducting and electrical connections are working before completing the final part 9 Finally lift the bottom outside stainless steel section upwards take care not to scratch this section and secure to the two top mounting brackets with screws provided See cleaning instructions on p...

Page 21: ...glass lenses fall If your Lights do not have the inner Black steel ring and are just a plain brushed steel fitting then this will need to be twisted instead to gain access to the bulb SEE IMAGE 2 4 Now remove the halogen light bulb from the light fitting Please note that the halogen bulb has two long prongs and will need to be removed by pulling firmly sideways 5 Once you have removed the old bulb...

Page 22: ...rom your hood to expose the light fitting located at the back of your hood this only applies to standard hoods 2 Twist the bulb anticlockwise to remove replace with a 20 40 w max screw bulb Bulbs are not covered by warranty and can be purchased from the Luxair Website www luxairhoods com ...

Page 23: ...Metal grease filters to allow you access to the inside of the hood 2 Once removed you will be able to push the light fitting out from inside the hood 3 You will now be able to see the connector which you can now disconnect and reconnect the new light fitting 4 Now push the fitting back into place Connector ...

Page 24: ...ng on the top chimney section to allow the air to get out of the hood and that they are not obstructed or blocked see page 8 Please Note If hood is on a pertition or stud wall this will cause vibration and cause the hood to be noisey due to the wall being hollow Poor Extraction Check the ducting size 125mm see page 7 If the ducting is run too far over the recommended 3 5mtrs 5 5 mtrs on island hoo...

Page 25: ...or the screw out fuse is removed in countries where this is applicable The surfaces and controls are susceptible to scratches and abrasions Please observe the following cleaning instructions All external surfaces and controls can be cleaned w i th warm water and a little washing up liquid applied with a well wrung out soft sponge or cloth Wipe the surfaces dry using a soft cloth Do not use too muc...

Page 26: ...th a soft nylon brush in a mild solution of hot water and a little washing up liquid Do not use neat washing up liquid Do not use Cleaning agents containing descaling agents Alkaline cleaning agents with a pHvalue higher than 7 such as powder cleaners cream cleaners or abrasive all purpose cleaning agents Oven sprays Cleaning the grease filter in the dishwasher Place the filter with the short side...

Page 27: ... 0 Extraction sys tem 150 mm Level I 200 m h3 Level II 300 m h3 Level III 650 m h3 0 Extraction sys tem 125 mm Level I 180 m h3 Level II 280 m h3 Level III 550 m h3 Unrestricted 680 m h3 For EXT models the connected load and ex traction power will depend on the type of external motor fitted EXT models Length of connection cable to external motor 1 9 m Decibel ratings Noise Level Min Max CBM H Spee...

Page 28: ...arranty this form must also be returned to Luxair within 31days After installation in order to receive the extended warranty on our products Once we receive your Warranty registration you will receive a warranty confirmation letter please keep this safe in the event of a claim If you do not receive this after 14 days of registering please contact Luxair Warranty s can also be registered online at ...

Page 29: ...month manufacturer s warranty as standard All models must be installed on 125mm ducting Failure to do so will result in your warranty being invalid and any service call will be chargeable as well as parts used to rectify the fault Information Supplied You should ensure that any information supplied by you is correct before proceeding to payment Luxair UK Limited does not accept responsibility or o...

Page 30: ...product registration Proof of purchase may be required in the event of a claim Once your product is registered you will receive confirmation via email or letter for you to keep as proof of registration If you do not receive confirmation within 14 days of registering please advise Luxair immediately It is advised if registering via post to send recorded delivery in the event that we do not have you...

Page 31: ...funded as these have been accepted as seen Return of Unwanted Goods Luxair must be notified within 7 days if goods are no longer required or have been purchased in error We will refund in full or replace damaged or faulty goods only if installation has not taken place Unwanted goods must be returned at your own cost and will be subject to a 25 restocking fee All goods must be returned in perfect r...

Page 32: ...e Barker Business Park Mel merby Ripon North Yorkshire HG4 5NB Telephone OO44 0 1765 641888 Fax 0044 0 1765 641889 Help Line 0044 0 1765 641888 Email info luxairhoods com Web www l uxairhoods com Alteration rights reserved 1306 M Nr 06 783 600 02 en GB ...

Reviews: