background image

SV09628 rev. 03

CC700 SERIES

INTENDED FOR DOMESTIC COOKING ONLY

INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER.

HOMEOWNER: USE AND CARE INFORMATION 

ON PAGES 19 TO 20.

Venmar Ventilation Inc., 550 Lemire Blvd., Drummondville  QC   J2C 7W9

1-800-567-3855

REGISTER YOUR PRODUCT ON LINE AT: www.bnv.ca

For additional information, visit 

www.venmar.ca or www.ispira.ca

HB0046

INSTALLATION INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS

Summary of Contents for CC700 SERIES

Page 1: ... HOMEOWNER USE AND CARE INFORMATION ON PAGES 19 TO 20 Venmar Ventilation Inc 550 Lemire Blvd Drummondville QC J2C 7W9 1 800 567 3855 REGISTER YOUR PRODUCT ON LINE AT www bnv ca For additional information visit www venmar ca or www ispira ca HB0046 INSTALLATION INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS ...

Page 2: ...ON when cooking at high heat or when flambeing food i e Crêpes Suzette Cherries Jubilee Peppercorn Beef Flambé c Clean ventilating fans frequently Grease should not be allowed to accumulate on fans filters or exhaust ducts d Use proper pan size Always use cookware appropriate for the size of the surface element WARNING TO REDUCETHE RISK OF INJURYTO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE O...

Page 3: ...ALL CAP MODEL 634 OR 644 ROOF CAP 6 ROUND ADJUSTABLE ELBOW OPTIONAL MODEL 428 OPTIONAL 3 X 10 ELBOW ADAPTER DAMPER 3 X 10 SUPPLIED WITH HOOD FOR HORIZONTAL OR VERTICAL DISCHARGE MODEL 401 3 X 10 STANDARD DUCT 6 ROUND STANDARD DUCT ADAPTER DAMPER 6 ROUND SUPPLIED WITH HOOD FOR VERTICAL DISCHARGE UPPER DECORATIVE FLUE LOWER DECORATIVE FLUE ...

Page 4: ...how the ductwork will be installed A straight short duct run will allow the hood to perform most efficiently Install proper sized ductwork elbows and roof or wall cap Connect metal ductwork to cap and work back towards the hood location Use 2 metal foil duct tape to seal the joints We recommend to install the hood at a minimum distance of 24 from an electric range and at 30 from a gas range 3 X 10...

Page 5: ... inside decorative flue 6 Adapter Damper for vertical discharge in a bag taped inside decorative flue Installation manual Bag of parts taped inside the hood including 5 no 8 x 1 countersunk screws 8 no 8 x 3 4 screws 2 no 8 x 1 2 screws 6 no 8 x 3 8 screws 6 drywall anchors 3 washers 2 foam squares If need be discard extra parts Parts sold separately Ducts elbows wall and roof caps Refer to page 3...

Page 6: ...rge HK0061A 3 6 DIA C L 1415 16 1715 16 36 WIDTH HOOD 30 WIDTH HOOD VERTICAL DISCHARGE USING 6 ROUND ADAPTER DAMPER 2 PREPARE THE INSTALLATION CONT D 3 REMOVE BAFFLE FILTERS Lay the back of the hood on a table Use a piece of cardboard to avoid damaging the table or the hood Remove tape on filters Remove filters by pushing them towards the back and rotate then set the filters aside HO0182 ...

Page 7: ...ALL GLASS PANEL WG MODELS ONLY The WG hood models decorative glass panels are sold separately and have to be installed before completing the hood installation HD0428 SCREW LOCATIONS 7 3 Insert glass panel studs in appropriate hood holes 4 While holding glass panel pre tighten previously removed nuts by hand Ensure glass panel is centered Then using a 3 8 socket tighten nuts completely 5 Reinstall ...

Page 8: ...d See illustrations at right 1 2 1 2 HR0068 VERTICAL DISCHARGE HORIZONTAL DISCHARGE 1 Using a Robertson or a Phillips no 2 screwdriver remove the 4 electrical compartment cover retaining screws Set cover and screws aside 6 BLOWER REMOVAL HORIZONTAL DISCHARGE ONLY The CC700 Series range hoods are factory shipped with the blower mounted for a vertical discharge configuration For a horizontal dischar...

Page 9: ... screwdriver remove the 6 light panel retaining screws only 3 out of 6 screws illustrated at right Set screws aside HD0429 SCREW LOCATIONS SAME ON BOTH SIDES 6 BLOWER REMOVAL HORIZONTAL DISCHARGE ONLY CONT D 3 Remove light panel following the 3 steps shown at right and set aside HO0191 1 2 3 HE0123 4 Unplug the blower ...

Page 10: ...NTING SCREW LOCATION HD0386 RIGHT SIDE MOUNTING SCREW LOCATION Mount the 3 x 10 adapter damper to the back of the hood using 2 no 8 x 3 8 screws included Seal the adapter damper to the hood using metal foil duct tape NOTE The wall ducting must be properly prepared to receive the adapter Before performing the installation make sure the adapter fits easily in the duct 7 INSTALL ADAPTER DAMPER HJ0062...

Page 11: ...f an electrical short circuit grounding reduces the risk of electric shock by providing an escape wire for the electric current This appliance is equipped with a cord having a grounding wire with a grounding plug The plug must be plugged into an outlet that is properly installed and grounded WARNING Improper grounding can result in a risk of electric shock Consult a qualified electrician if the gr...

Page 12: ...LL HOOD MOUNTING BRACKET Construct wood wall framing that is flush with surface of wall studs Ensure to assemble wood wall framing to wall studs for a solid installation Make sure the height of the framing will allow the mounting bracket to be secured to the framing within the dimensions shown see illustration at right After wall surface is finished carefully center and level the hood mounting bra...

Page 13: ...installing the decorative flue and hood they may have sharp edges 1 Align the hood and center it above the hood mounting bracket Gently lower the hood until it securely engages the bracket 2 Level the hood 3 Mark the position of both holes located inside lower back of hood as shown at right Also mark the position of 2 of the 6 available upper holes one on each side Remove the hood Drill through fo...

Page 14: ...rsing instructions of step 6 3 3 Connect both light assemblies electrical harnesses to light connectors and secure light panel to hood using the 6 previously removed screws in 6 2 4 Reinstall electrical compartment cover using the 4 previously removed screws in 6 1 5 Plug the blower back in and plug hood power cord into the outlet 13 DUCT CONNECTION VERTICAL DISCHARGE ONLY 1 Plug hood power cord i...

Page 15: ...oth corners at the top of the upper flue 3 Position the lower flue rear notches down 4 Gently slide upper flue inside lower flue HO0183 LOWER FLUE REAR NOTCH 15 1 To prevent the flue from moving affix the included foam squares on both sides near the front edge of the blower box as illustrated at right 2 Carefully slide in place decorative lower flue notches end first on top of the hood 1 until flu...

Page 16: ...RONT VIEW UPPER FLUE 4 Remove protective plastic film covering the upper flue 2 Rest rear filters edge on filter springs in the range hood Using knob tilt up the filters into position Make sure filter tabs are securely engaged in range hood front edge after installation 16 REINSTALL BAFFLE FILTERS HO0184 FILTER TABS CAUTION Remove protective plastic film covering filters before reinstalling them 1...

Page 17: ...beyond the blower box limits BLOWER BOX 4 Slide the blower box in the opening and secure the hood to the bottom of the cabinet using 6 screws Secure the hood to the wall by inserting a screw in 1 of the 3 available holes on each side of the blower box 1 screw on each side NOTES For horizontal discharge only Ensure the adapter damper enters the duct opening and seal joint from inside the hood using...

Page 18: ...ngage bulb leads from their grooves 2 Place the new bulb leads into their grooves in the socket 3 Gently push upward and turn clockwise until secured NOTE If need be use a rubber dishwashing glove to add grip when removing the bulb 1 2 3 HO0089 WARNING Do not touch lamps during or soon after operation Burns may occur In order to prevent the risk of personal injury only install shielded halogen lam...

Page 19: ...e Do Regularly wash with clean cloth or rag soaked with warm water and mild soap or liquid dish detergent Always clean in the direction of original polish lines Always rinse well with clear water 2 or 3 times after cleaning Wipe dry completely You may also use a specialized household stainless steel cleaner Don t Use any steel or stainless steel wool or any other scrapers to remove stubborn dirt U...

Page 20: ...ort lapse of time and then resume on speed 1 C MASTER ON OFF When blower and lights are off press this button to turn the hood on to the last memorized speed level and light intensity If there are no memorized speed level and light intensity speed will be set at level 1 and light intensity at 4 To turn off the blower and the light simultaneously press this button once HEAT SENTRY The hood is equip...

Page 21: ...y to recommended installation instructions Warranty service is to be completed by an authorized Service Center designated by Venmar Ventilation Inc Where applicable in home service will be made available only in areas where a contracted service provider offers service If in home service is not available the product will be repaired or replaced at Venmar s discretion by the nearest authorized servi...

Page 22: ...TH 30 36 1 SV19135 UPPER FLUE MOUNTING BRACKET 1 1 2 SV19134 UPPER DECORATIVE FLUE 1 1 3 SV19133 LOWER DECORATIVE FLUE 1 1 4 SV09014 HOOD MOUNTING BRACKET 1 1 5 SV09955XX GLASS PANEL 1 SV09956XX GLASS PANEL 1 6 SV09550 ELECTRONIC CONTROL 1 1 7 SV09549 POWER UNIT 1 1 8 SV05917 SOCKET 2 2 9 SV09435 SOCKET HOLDER 2 2 10 SV09434 LIGHT TRIM 2 2 11 SV05921 SHIELDED HALOGEN BULB 120 V 50 W GU10 2 2 12 SV...