– 55 –
Test
No.
Test Name
Description
11
Door Open/
Close Test
• Press the Start button to begin test.
• The control will display "dc" if the door is closed or "do" if the door is open.
• Rotate the cycle knob to end current test and advance to next test.
12
Door Latch
• Latch Disabled Test. Open the door.
• Press the Start button.
• The control should display "LC" for latch clear.
• Latch Set Test. Close the door. Press the Start button.
• The control should display "LS" for latch set.
• Rotate the cycle knob to end current test and advance to next test.
13
Clear Fault
Codes
• Pressing the Start button will clear all Fault Codes.
• When cleared the display will show " - - ".
• Rotate the cycle knob to end current test and advance to next test.
14
Steam Valve
• Be sure the door is closed.
•
Press the Start button to toggle the water valve On and Off.
• Seven Segment Display (SSD) will show either “on” or “OFF”.
• Valve will have a time limit of 1-minute.
•
Valve will turn off upon exit of test.
• Rotate the cycle knob to end current test and advance to next test.
15
Change
Personality
• Pressing Start/Pause will start the test.
• Pressing the Start pad will display the next valid personality.
• Pressing and holding the Start pad to select the personality and exit
Service Mode.