– 30 –
3. Reinstall the mesh using the male part of the
Nozzle/Mesh installation tool that comes in
the kit. Place the new mesh onto the tool and
insert the mesh inside the nozzle base. The
tool will set the mesh to the proper depth in
the nozzle base.
4.
Finally, use fingers to prevent cross-threading,
then attach the nozzle to the nozzle base
finger tight. With a pair of pliers and the
Nozzle/Mesh Installation Tool socket that
comes in the kit, tighten the nozzle to the
nozzle base.
Base Replacement
The mist nozzle base is mounted to the rear drum
support. If the mist nozzle base needs to be
replaced, the rear panel will need to be removed.
Then remove the two 1/4-inch hex-head screws
that secure the base to the rear drum support.