– 36 –
4. Using the belt as a handle, lift the drum from
the cabinet.
NOTE
: The felt on the front and back of the drum
are not separate parts. They come with the drum.
Looking at Idler Pulley from Front of Dryer
Pull Idler Pulley to the Right
The electric heater assembly has an upper
and lower heater in the housing, which comes
assembled together. It also has the inlet and high
limit thermostats mounted to the left side of the
heater housing.
Heater Diagnosing
1. Disconnect power from the dryer.
2. Access the main board located under the top
panel.
3. Disconnect either the
blue
wire from the
normally open (N.0.) terminal of the K502
relay or the
orange
wire from the normally
open (N.0.) terminal of the K501 relay.
Electric Heater Assembly
Electric
Heater
Assembly
High
Limit
T-Stat
Inlet
T-Stat