![Haier GE NF96DS Service Manual Download Page 3](http://html1.mh-extra.com/html/haier/ge-nf96ds/ge-nf96ds_service-manual_3280138003.webp)
Page 3
31-5000729 Rev. 0
Technical Specifications -NF96DS
PHYSICAL AND ELECTRICAL DATA
Model
Input
(Btuh)
Output
(Btuh)
AFUE
(ICS)
Nominal
Cooling
Capacity
Gas
Inlet
(in.)
Volts/
Hz/
Phase
Max.
Time
Delay
Breaker
or Fuse
Nominal
F.L.A.
Trans.
(V.A.)
Approx.
Shipping
Weight
(lbs.)
Downflow
NF96D045S3B
44,000
43,000
96.0%
3 Ton
1/2
120-60-1
15
6.8
40
131
NF96D070S4B
66,000
64,000
96.0%
4 Ton
1/2
120-60-1
15
8.4
40
144
NF96D090S4C
88,000
86,000
96.0%
4 Ton
1/2
120-60-1
15
8.4
40
160
Note: For vent length and clearances to combustibles, please reference installation instructions.
MODEL NUMBER GUIDE
MAJOR/MINOR REVISION
CABINET WIDTH
B - 17.5
C - 21
NOMINAL CFM
3 - 1200 CFM
4 - 1600 CFM
5 - 2000 CFM
DESIGN VARIANT
S - ECM, 1-STAGE
BRAND
N - GE
PRODUCT
F - FURNACE, GAS
AFUE
96 = 96% EFFICIENCY
APPLICATION
U - UPFLOW/HORIZONTAL, STANDARD EMISSION
D - DOWNFLOW, STANDARD EMISSION
HEATING INPUT (1000 BTU/HR)
45, 70, 90, 110
N
N FF 96
96 D
D
SS 55 C
C XX
XX
110
110