Below are listed four kinds of Safety Cautions and Suggestions:

Be sure to conform with the following important Safety Cautions.

The Safety Cautions should be at hand so that they can be checked at any time when needed.

If the air conditoner is transferred to the new user, this manual should be as well transferred to the new

user.

Safety Cautions

Incorrect operations may result in severe consequences of death or serious injures.

WARNING:

Incorrect operations may result in injures or machine damages; in some cases may
cause serious consequences.

CAUTION :

: It must be strictly prohibited where marked with ì Prohibited î, otherwise may result in
  machine damages or endanger the userípersonal safety.

This information can ensure the correct operation of the machine.

INSTRUCTION:

Carefully read the following information in order to operate the air conditioner correctly.

WARNING

If any abnormal phenomena are found (e.g.
smell of firing),please cut off the power supply
immediately, and contact the dealer to find outí
the handling method.

When need maintenance and

repair,call dealer to handle it.

Donít put figures or any other

things into the inlet/outlet and

swing louver while the conditi-

oner is in operation

Call the dealer to take measures to prevent the
refrigerant from leaking.

Switch
off

In such case,to continue using
the air conditioner will damage
the conditioner,and may cause
electrical shock or fire hazard.

Incorrect maintenance and repair
may cause water leak,
electrical shock and fire hazard.

Because the high-speed fan
is very dangerous and may cause
injures.

The leaked refrigerant over certain density may
cause oxygen deficient.If the air conditioner is
installed in a small room be sure to take measure
in order to prevent suffocation accident even in
case of refrigerant leakage

When air conditioner is removed and reinstalled
dealer should be responsible for them.

Incorrect installation may cause water leaking,
electrical shock and fire hazard.

Donít dismantle the outlet of the outdoor unit.

The exposure of fan is very
dangerous witch may harm
human beings.

After a long time use of air conditioner the base
should be checked for any damages.

If the damaged base is not
repaired, the unit may fall
down and cause accidents.

15

6. Installation of Ornament Panel

Install ornament panel on indoor unit

(1) Check whether indoor unit is horizontal with leveler or polythene pipe filled with water , and
      check that the dimension of the ceiling opening is correct. Take off the lever gauge before install
      the ornament panel.
(2) Fasten the screws to make the height difference between the two sides of indoor unit less than
     5mm.

(3) First fix it with screws temporally.

(4) Fasten the two temporally fixing screws and other two, and tighten the four screws.

(5) Connect the wires of synchro-motor.

(6) Connect the wire of signal.

(7) If no response of remote controller,check whether the wiring is correct,restart remote controller
     10 seconds after shut off power supply.

Limits of panel board installation

(1)Install the panel board in the direction shown in
     the figure.
(2)The incorrect direction will result in water leakage,
     meanwhile swing and signal receiving are displayed
     that cannot be connected.

Installation Procedures

Summary of Contents for AB092FCAIA

Page 1: ...OUP Qingdao Haier Air Conditioner Electric Co Ltd Address Haier Garden Qianwangang Road Economic Development Zone Qingdao Shandong 266500 P R China Web Site http www haier com Cautions Main Points of Operation Name of Each Part Safety Cautions Maintenance When Trouble Happens Customer Need to know Installation Procedures Trouble Shooting Installation Procedures Check and Test Run 1 2 3 4 5 6 7 8 9...

Page 2: ... of an old air conditioner and contact your local authority or your dealer if you have any question Please ensure that the pipework of your air conditioner does not get damaged prior to being picked up by the relevant waste disposal center and contribute to environmental awareness by insisting on an appropriate anti pollution method of disposal Disposal of the packaging of your new air conditioner...

Page 3: ...ipe cutter Expand flare after insert the pipe expander Installation check and test run Require customers to use air conditioner according to the operation manual The items checked during test run please mark in No gas leakage on the pipe joint How about the thermal insulation of the pipe joint Is the electrical wiring between indoor and outdoor unit connected to the terminal block firmly Is the wi...

Page 4: ...ff the power supply switch immediately and contact the sales dealer Trouble Shooting 3 Main points of Operation Operation of Air Conditioner When the environmental humidity is great water maybe dripped from the air outlet in cooling or drying mode 3 minute Protection Function If restart the unit immediately after stopping the compressor will start only 3 minutes later to protect the machine Variat...

Page 5: ...will not be used for a long time please cut off the power supply to prevent its operation from being resumed after the power is supplied again or press the ì Switch On Off î button after the power comes again Defrosting Running Wait a minute 17 The followings are not malfuncition Hua Hua Trouble Shooting Water flowing sound is heard When the air conditoner is started when the compressor starts or ...

Page 6: ...st or deform the connecting pipe Do not mix dusts The bending radius shall be as large as possible Both gas pipe and liquid pipe shall be heat insulation No leakage in the flare 3 Piping connection Connecting method Smear refrigerant oil on the joints of piping and flare The bending radius shall be as large as possible Align the pipe center when fastening and tighten the nut as shown in the figure...

Page 7: ...cause the high speed fan is very dangerous and may cause injures The leaked refrigerant over certain density may cause oxygen deficient If the air conditioner is installed in a small room be sure to take measure in order to prevent suffocation accident even in case of refrigerant leakage When air conditioner is removed and reinstalled dealer should be responsible for them Incorrect installation ma...

Page 8: ...s electrical shock without circuit breaker Not permitted when running 14 4 Installation of water drainage pipe 1 Install water drainage pipe Pipe diameter shall be equal or larger than that of connecting pipe Pipe of polythene size 25mm O D 32mm Drainpipe should be short with a downward slope at least 1 100 to prevent air bag from forming If downward slope of drainpipe cannot be made lifting pipe ...

Page 9: ...pretared in the field Before going on installing adjust space to ceiling 3 Installation of indoor unit In case of no ceiling Install unit temporally Put suspending bracket on the suspending bolt to hang the unit up Be sure to use nut and washer at both end of the breaket to secure firmly After installation on the ceiling 1 Adjust unit to its right position Refer to preparation for installation 1 2...

Page 10: ...oor and outdoor unit will not be blocked 4 Do not expose the unit to the place with heavy oil or moisture e g kitchen and workshop 5 Do not set the unit in the place where destructive gas such as sulfuric acid gas or pungent gas thinner and gasoline concentrates and retains 6 Place strong enough to support the unit weight 7 No expensive articles such as television and piano below indoor unit 8 Eno...

Page 11: ......

Reviews: