Main points of Operation

Prevent Cool Air Blowing Off

In heating mode,the indoor fan will not run
immediately after the unit starts to prevent
the cool air blowing off.

Defrosting Function

In heating mode, when frost formed on the outdoor heat
exchanger, the air conditioner will automatically defrost a
few minutes. During defrosting, both indoor and outdoor
fan will stop running. When defrosting finished, air condi-
tioner will automatically back to running.

Hints

The air conditioner absorbs heat form outside and
releases inside when in heating mode, therefore the
outside environmental temperature will affect heating
effects.

Power Failure Compensation(to be applied for a necessary situation):

After the power failure compensation is set, if power failure suddenly occurs while the air
conditioner is working,it will resume the previous working state when the power is supplied
again.

Setting Method: When the remote controller is on (excluding timer mode and fan mode),press
                          the ìsleepî button on the remote controller 10 times within 5 seconds,and
                          after the buzzer rings 4 times, the air conditioner will enter the state of power
                          failure compenstation.

Cancel Method:Press the ìsleepî button on the remote controller 10 times within 5 seconds,
                         and after the buzzer rings 2 times, the power failure compensation mode will be
                         cancelled.

Note: When a power failure suddenly occurs during the air conditioner is working after the
         power failure compensation is set,if the air conditioner will not be used for a long
         time, please cut off the power supply to prevent its operation from being resumed
           after the power is supplied again, or press the ì Switch On/Off î button after the power
          comes again.

Defrosting Running

Wait a
minute

17

The followings are not malfuncition

Hua

Hua

Trouble Shooting

Water flowing sound is heard

When the air conditoner is started, when the
compressor starts or stops during operation
or when the air conditioner is stopped,it som-
etimes sounds ì Bi- Bi-î or ìGodo-Godoî. It is
the flowing sound of the refrigerant , not a
malfunction.

Cracking sound is heard

It smells.

This is caused by heat expansion or contra-
ction of plastics

Air blown out from the indoor unit sometimes
smells. The smell results from smells of
furniture, paint , tobacco absorbed by indoor
unit.

During operation, white fog comes out of
indoor unit.

When in COOL or DRY mode, a thin water
fog can be seen blown out of unit ,this is the
condensed fog because the suddenly cooled
indoor air is blown out.

Automatically switch into FAN mode during
cooling.

To prevent frost from being accumulated on the
indoor unit heat exchanger, it sometimes auto-
matically switched into the FAN mode,but it will
soon back to the cooling mode.

The air conditioner cannot be restarted soon
after it stops.
Air conditioner does not start?

This is because of the self-protection function
of the system, therefore,it cannot be restarted
for about three minutes after it stops.

Please wait for
three minutes

In function of code B ,set and cancel Auto restart function by using of "SWING" button.

Note:

Series remote controller units please press the remote controller botton "CODE" to choose the program of code "B"

Summary of Contents for AB092FCAIA

Page 1: ...OUP Qingdao Haier Air Conditioner Electric Co Ltd Address Haier Garden Qianwangang Road Economic Development Zone Qingdao Shandong 266500 P R China Web Site http www haier com Cautions Main Points of Operation Name of Each Part Safety Cautions Maintenance When Trouble Happens Customer Need to know Installation Procedures Trouble Shooting Installation Procedures Check and Test Run 1 2 3 4 5 6 7 8 9...

Page 2: ... of an old air conditioner and contact your local authority or your dealer if you have any question Please ensure that the pipework of your air conditioner does not get damaged prior to being picked up by the relevant waste disposal center and contribute to environmental awareness by insisting on an appropriate anti pollution method of disposal Disposal of the packaging of your new air conditioner...

Page 3: ...ipe cutter Expand flare after insert the pipe expander Installation check and test run Require customers to use air conditioner according to the operation manual The items checked during test run please mark in No gas leakage on the pipe joint How about the thermal insulation of the pipe joint Is the electrical wiring between indoor and outdoor unit connected to the terminal block firmly Is the wi...

Page 4: ...ff the power supply switch immediately and contact the sales dealer Trouble Shooting 3 Main points of Operation Operation of Air Conditioner When the environmental humidity is great water maybe dripped from the air outlet in cooling or drying mode 3 minute Protection Function If restart the unit immediately after stopping the compressor will start only 3 minutes later to protect the machine Variat...

Page 5: ...will not be used for a long time please cut off the power supply to prevent its operation from being resumed after the power is supplied again or press the ì Switch On Off î button after the power comes again Defrosting Running Wait a minute 17 The followings are not malfuncition Hua Hua Trouble Shooting Water flowing sound is heard When the air conditoner is started when the compressor starts or ...

Page 6: ...st or deform the connecting pipe Do not mix dusts The bending radius shall be as large as possible Both gas pipe and liquid pipe shall be heat insulation No leakage in the flare 3 Piping connection Connecting method Smear refrigerant oil on the joints of piping and flare The bending radius shall be as large as possible Align the pipe center when fastening and tighten the nut as shown in the figure...

Page 7: ...cause the high speed fan is very dangerous and may cause injures The leaked refrigerant over certain density may cause oxygen deficient If the air conditioner is installed in a small room be sure to take measure in order to prevent suffocation accident even in case of refrigerant leakage When air conditioner is removed and reinstalled dealer should be responsible for them Incorrect installation ma...

Page 8: ...s electrical shock without circuit breaker Not permitted when running 14 4 Installation of water drainage pipe 1 Install water drainage pipe Pipe diameter shall be equal or larger than that of connecting pipe Pipe of polythene size 25mm O D 32mm Drainpipe should be short with a downward slope at least 1 100 to prevent air bag from forming If downward slope of drainpipe cannot be made lifting pipe ...

Page 9: ...pretared in the field Before going on installing adjust space to ceiling 3 Installation of indoor unit In case of no ceiling Install unit temporally Put suspending bracket on the suspending bolt to hang the unit up Be sure to use nut and washer at both end of the breaket to secure firmly After installation on the ceiling 1 Adjust unit to its right position Refer to preparation for installation 1 2...

Page 10: ...oor and outdoor unit will not be blocked 4 Do not expose the unit to the place with heavy oil or moisture e g kitchen and workshop 5 Do not set the unit in the place where destructive gas such as sulfuric acid gas or pungent gas thinner and gasoline concentrates and retains 6 Place strong enough to support the unit weight 7 No expensive articles such as television and piano below indoor unit 8 Eno...

Page 11: ......

Reviews: