2

    All electrical repairs must be carried out
by qualified electricians. Inadequate repairs
may result in a major source of danger for
the user of the air conditoiner.

  Do not damage any parts of the air
conditioner that carry refrigerant by
piercing or perforating the air conditioner's
tubes with sharp or pointed items, crushing
or twisting any tubes, or scraping the
coatings off the surfaces. If the refrigerant
spurts out and gets into eyes, it may result
in serious eye injuries.

  Do not obstruct or cover the ventilation
grille of the air conditioner. Do not put
fingers or any other things into the
inlet/outlet and swing louver.

   Do not allow children to play with the air
conditioner. In no case should children be
allowed to sit on the outdoor unit.

Specifications

The refrigerating circuit is leak-proof.

1. Applicable ambient temperature range:

The machine is adaptive in following
situation

2. If the supply cord is damaged, it must be
    replaced by the manufacturer or its service
    agent or a similar qualified person.
3. If the fuse on PC board is broken please
    change it with the type of  T3.15A /250VAC.

Cautions

Cooling

Heating

Indoor

outdoor

Rated Maximum Minimum
  27           32             18
  19           23             14
  35           43              -5
  24           26              --
  20           27              15
 14.5          --               --
   7             21            -15
   6             15              --

DB  C
WB  C
DB  C
WB  C

Indoor

outdoor DB  C

WB  C

DB  C
WB  C

2

2

19

Other Instructions

1.Configuration of power supply

Air conditioner must use special power supply system (above 20A), and qualified electrician makes
wiring and fixing according to wiring regulations specified in national standard.

In socket, exactly distinguish earth wire with neutral wire and it is wrong to connect them together.
A leakage breaker must be installed.

Parameters of power supply: H07RN-F 3G 2.0

mm

2

Connection method is Y-connection .If the power cord is damaged, it must be replaced by
professional people of manufacturer or its maintenance department or similar to avoid dangers.

2.Pipe cutting and expanding

Must remove burrs if cut pipes with pipe cutter.
Expand flare after insert the pipe expander.

Installation check and test run

Require customers to use air conditioner according to the operation manual.
The items checked during test run,please mark       in

No gas leakage on the pipe joint ?
How about the thermal insulation of the pipe joint:

Is the electrical wiring between indoor and outdoor unit connected to the terminal block firmly?

Is the wiring of indoor and outdoor unit secured firmly?
Is the drainage hose arranged correct?

Is the earthing wire connected firmly?
Is the power supply voltage conformed to the electrical regulation?
Any noise?

Is the display on the control board (LCD) correct?
Cooling normal?

Does the indoor temperature regulator work normally?

For the power supply

L   shall be connected to the live wire.

N   shall be connected to the neutral wire.

Shall be connected to the earth wire.

The  person  who  has  completed  this  installation  shall  be  requested  to  conduct  a test  operation  for  check:

Is  the  temperature  adjuster  working  normally?
Does  the  location  for  installation  conform  to  requirements?

Winding  up  with  Protective  Plastic  Tape

The  connection  pipes, drain  pipe, and  the  connection  wires
 shall  be  wound  up  with   PVC  tape.
Notes: The  connection  pipes  shall  also  be  wound  up  with  insulating
 material  to  preserve  the temperature.  The  airing  direction  shall  be
from  bottom  to  top.

Trial  Operation

Correct

Incorrect

Deflection

Crack occurs

Broken

Incomplete

Over outward

A

Pipe expander

Liquid pipe

Gas pipe

Diameter of pipe

Dimension A (mm)

1.0~1.2

1.4~2.2

6.35mm (1/4î)

12.7mm (1/2î)

Installation Procedures,Check and Test Run

4. The wiring method should be in line with
     the local wiring standard.
5. Use copper wire only. The connecting cable
    should be H05RN-F 4G 0.75mm  . The power
    cable should be H05RN-F 3G 2.5mm  .
    All the cables shall have got the European
    authentication certificate.
6. The waste battery shall be disposed properly.
7. The indoor unit installation height is at least
    2.5m.
8. The appliance must be installation that the
    plug should be easily accessible after
    installation.
9. The power plug should be self-provided and
     it should have got the Local authenti-
     cation certificate.

Summary of Contents for AB092FCAIA

Page 1: ...OUP Qingdao Haier Air Conditioner Electric Co Ltd Address Haier Garden Qianwangang Road Economic Development Zone Qingdao Shandong 266500 P R China Web Site http www haier com Cautions Main Points of Operation Name of Each Part Safety Cautions Maintenance When Trouble Happens Customer Need to know Installation Procedures Trouble Shooting Installation Procedures Check and Test Run 1 2 3 4 5 6 7 8 9...

Page 2: ... of an old air conditioner and contact your local authority or your dealer if you have any question Please ensure that the pipework of your air conditioner does not get damaged prior to being picked up by the relevant waste disposal center and contribute to environmental awareness by insisting on an appropriate anti pollution method of disposal Disposal of the packaging of your new air conditioner...

Page 3: ...ipe cutter Expand flare after insert the pipe expander Installation check and test run Require customers to use air conditioner according to the operation manual The items checked during test run please mark in No gas leakage on the pipe joint How about the thermal insulation of the pipe joint Is the electrical wiring between indoor and outdoor unit connected to the terminal block firmly Is the wi...

Page 4: ...ff the power supply switch immediately and contact the sales dealer Trouble Shooting 3 Main points of Operation Operation of Air Conditioner When the environmental humidity is great water maybe dripped from the air outlet in cooling or drying mode 3 minute Protection Function If restart the unit immediately after stopping the compressor will start only 3 minutes later to protect the machine Variat...

Page 5: ...will not be used for a long time please cut off the power supply to prevent its operation from being resumed after the power is supplied again or press the ì Switch On Off î button after the power comes again Defrosting Running Wait a minute 17 The followings are not malfuncition Hua Hua Trouble Shooting Water flowing sound is heard When the air conditoner is started when the compressor starts or ...

Page 6: ...st or deform the connecting pipe Do not mix dusts The bending radius shall be as large as possible Both gas pipe and liquid pipe shall be heat insulation No leakage in the flare 3 Piping connection Connecting method Smear refrigerant oil on the joints of piping and flare The bending radius shall be as large as possible Align the pipe center when fastening and tighten the nut as shown in the figure...

Page 7: ...cause the high speed fan is very dangerous and may cause injures The leaked refrigerant over certain density may cause oxygen deficient If the air conditioner is installed in a small room be sure to take measure in order to prevent suffocation accident even in case of refrigerant leakage When air conditioner is removed and reinstalled dealer should be responsible for them Incorrect installation ma...

Page 8: ...s electrical shock without circuit breaker Not permitted when running 14 4 Installation of water drainage pipe 1 Install water drainage pipe Pipe diameter shall be equal or larger than that of connecting pipe Pipe of polythene size 25mm O D 32mm Drainpipe should be short with a downward slope at least 1 100 to prevent air bag from forming If downward slope of drainpipe cannot be made lifting pipe ...

Page 9: ...pretared in the field Before going on installing adjust space to ceiling 3 Installation of indoor unit In case of no ceiling Install unit temporally Put suspending bracket on the suspending bolt to hang the unit up Be sure to use nut and washer at both end of the breaket to secure firmly After installation on the ceiling 1 Adjust unit to its right position Refer to preparation for installation 1 2...

Page 10: ...oor and outdoor unit will not be blocked 4 Do not expose the unit to the place with heavy oil or moisture e g kitchen and workshop 5 Do not set the unit in the place where destructive gas such as sulfuric acid gas or pungent gas thinner and gasoline concentrates and retains 6 Place strong enough to support the unit weight 7 No expensive articles such as television and piano below indoor unit 8 Eno...

Page 11: ......

Reviews: