Cautions

1

   For the purpose of safety, the air
conditioner must be properly grounded in
accordance with specifications.

   Always remember to unplug the air
conditioner before opening inlet grill. Never
unplug your air conditioner by pulling on the
power cord. Always grip plug firmly and
pull straight out from the outlet.

     The air breaker should be all-pole switch.
and the distance between it's two connecters
should be no less than 3mm.

     Damaged air conditioners are not to be
put into operation. In case of doubt, consult
your supplier.

    Use of the air conditioner is to be carried
out in strict compliance with the relative
instructions set forth in the User's Guide.

     Installation shall be done by professional
people, don't install unit by yourself.

Disposal of the old air conditioner

Before disposing an old air conditioner
that goes out of use, please make sure it's
inoperative and safe. Unplug the air
conditioner in order to avoid the risk of
child entrapment.

It must be noticed that air conditioner
system contains refrigerants, which require
specialized waste disposal. The valuable
materials contained in a air conditioner can
be recycled. Contact your local waste
disposal center for proper disposal of an
old air conditioner and contact your local
authority or your dealer if you have any
question. Please ensure that the pipework
of your air conditioner does not get
damaged prior to being picked up by the
relevant waste disposal center, and
contribute to environmental awareness by
insisting on an appropriate, anti-pollution
method of disposal.

Disposal of the packaging of your new
air conditioner

All the packaging materials employed in
the package of your new air conditioner
may be disposed without any danger to the
environment.

The cardboard box may be broken or cut
into smaller pieces and given to a waste
paper disposal service. The wrapping bag
made of polyethylene and the polyethylene
foam pads  contain no fluorochloric
hydrocarbon.

Consult your local authorities for the name and
address of the waste materials collecting
centers and waste paper disposal services
nearest to your house.

Safety Instructions and Warnings

Before starting the air conditioner, read the
information given in the User's Guide
carefully. The User's Guide contains very
important observations relating to the
assembly, operation and maintenance of the
air conditioner.

The manufacturer does not accept
responsibility for any damages that may
arise due to non-observation of the following
instruction.

All these valuable materials may be taken to a
waste collecting center and used again after
adequate recycling.

Summary of Contents for AB092FCAIA

Page 1: ...OUP Qingdao Haier Air Conditioner Electric Co Ltd Address Haier Garden Qianwangang Road Economic Development Zone Qingdao Shandong 266500 P R China Web Site http www haier com Cautions Main Points of Operation Name of Each Part Safety Cautions Maintenance When Trouble Happens Customer Need to know Installation Procedures Trouble Shooting Installation Procedures Check and Test Run 1 2 3 4 5 6 7 8 9...

Page 2: ... of an old air conditioner and contact your local authority or your dealer if you have any question Please ensure that the pipework of your air conditioner does not get damaged prior to being picked up by the relevant waste disposal center and contribute to environmental awareness by insisting on an appropriate anti pollution method of disposal Disposal of the packaging of your new air conditioner...

Page 3: ...ipe cutter Expand flare after insert the pipe expander Installation check and test run Require customers to use air conditioner according to the operation manual The items checked during test run please mark in No gas leakage on the pipe joint How about the thermal insulation of the pipe joint Is the electrical wiring between indoor and outdoor unit connected to the terminal block firmly Is the wi...

Page 4: ...ff the power supply switch immediately and contact the sales dealer Trouble Shooting 3 Main points of Operation Operation of Air Conditioner When the environmental humidity is great water maybe dripped from the air outlet in cooling or drying mode 3 minute Protection Function If restart the unit immediately after stopping the compressor will start only 3 minutes later to protect the machine Variat...

Page 5: ...will not be used for a long time please cut off the power supply to prevent its operation from being resumed after the power is supplied again or press the ì Switch On Off î button after the power comes again Defrosting Running Wait a minute 17 The followings are not malfuncition Hua Hua Trouble Shooting Water flowing sound is heard When the air conditoner is started when the compressor starts or ...

Page 6: ...st or deform the connecting pipe Do not mix dusts The bending radius shall be as large as possible Both gas pipe and liquid pipe shall be heat insulation No leakage in the flare 3 Piping connection Connecting method Smear refrigerant oil on the joints of piping and flare The bending radius shall be as large as possible Align the pipe center when fastening and tighten the nut as shown in the figure...

Page 7: ...cause the high speed fan is very dangerous and may cause injures The leaked refrigerant over certain density may cause oxygen deficient If the air conditioner is installed in a small room be sure to take measure in order to prevent suffocation accident even in case of refrigerant leakage When air conditioner is removed and reinstalled dealer should be responsible for them Incorrect installation ma...

Page 8: ...s electrical shock without circuit breaker Not permitted when running 14 4 Installation of water drainage pipe 1 Install water drainage pipe Pipe diameter shall be equal or larger than that of connecting pipe Pipe of polythene size 25mm O D 32mm Drainpipe should be short with a downward slope at least 1 100 to prevent air bag from forming If downward slope of drainpipe cannot be made lifting pipe ...

Page 9: ...pretared in the field Before going on installing adjust space to ceiling 3 Installation of indoor unit In case of no ceiling Install unit temporally Put suspending bracket on the suspending bolt to hang the unit up Be sure to use nut and washer at both end of the breaket to secure firmly After installation on the ceiling 1 Adjust unit to its right position Refer to preparation for installation 1 2...

Page 10: ...oor and outdoor unit will not be blocked 4 Do not expose the unit to the place with heavy oil or moisture e g kitchen and workshop 5 Do not set the unit in the place where destructive gas such as sulfuric acid gas or pungent gas thinner and gasoline concentrates and retains 6 Place strong enough to support the unit weight 7 No expensive articles such as television and piano below indoor unit 8 Eno...

Page 11: ......

Reviews: