background image

27

Hague Filter Owner's Manual

MANUAL REGENERATION

NOTE: If you need to initiate a manual regeneration, either immediately, 

or the same night at the pre-programmed time for regeneration (typically 

12:00 AM), complete the following steps. 

For Immediate Regeneration:

 

Press and hold 

�����

 until valve motor starts (for 3 seconds) . 

For Regeneration the same night:

 

Press and release 

�����

 (notice that flashing “REGEN TODAY” appears) .

BYPASS VALVE OPERATION

To shut off water to the system, position arrow handles as shown in 

the bypass operation diagram below . If your valve doesn’t look like the 

diagram below, contact your service technician for instructions on how to 

shut off water .

NORMAL OPERATION

BYPASS OPERATION

GENERAL OPERATION

When the system is operating, one of four displays will be shown:

1 . Time of day/gpm

2 . Flow rate

3 . Capacity remaining

4 . Days to a regen

Pressing 

����

 will toggle between the four choices .

DAYS TO A REGEN

GPM

3

8

CAPACITY REMAINING

GPM

GAL

1600

8

FLOW RATE

GPM

8.0

TIME OF DAY

MON

GPM

2:40

8

PM

REGEN

UP

DOWN

NEXT

CLOCK

REGEN

UP

DOWN

NEXT

CLOCK

REGEN

UP

DOWN

NEXT

CLOCK

REGEN

UP

DOWN

NEXT

CLOCK

TO SET TIME OF DAY

In the event of a prolonged power outage, time of day flashes, indicating 

that this needs to be reset . All other information will be stored in memory 

no matter how long the power outage .

1 .  Accessed by pressing 

�����

2 .  Adjust hours with 

UP

 and 

DOWN

 buttons, AM/PM toggles at 12

3 . Press 

����

4 .  Adjust minutes with 

UP

 and 

DOWN

 buttons

5 . Press 

����

6 . Adjust current day with 

UP

 and 

DOWN

 buttons

7 .   Press 

����

 to complete and return to normal operation

CURRENT DAY

SET

MON

TIME

MINUTES

SET

TIME

HOUR

SET

2:00

AM

2:00

AM

TIME OF DAY

MON

GPM

2:40

8

PM

REGEN

UP

DOWN

NEXT

CLOCK

REGEN

UP

DOWN

NEXT

CLOCK

REGEN

UP

DOWN

NEXT

CLOCK

REGEN

UP

DOWN

NEXT

CLOCK

ERROR 

106

CALL FOR SERVICE

ERROR

If the display toggles between “Error” 

and an error code (i .e . a number), call a 

service technician and report the error 

code .

REGEN TODAY

MON

GPM

2:40

8

PM

REGEN TODAY 

and 

TIME OF DAY 

will flash alternately if a regeneration 

is expected tonight.

REGEN

UP

DOWN

NEXT

CLOCK

ADJUST DAYS BETWEEN 

REGENERATION, AND TIME 

OF REGENERATION

For initial set-up or to make adjustments, 

please complete the following steps .

1 .  Accessed by pressing 

����

 and 

UP

 button 

simultaneously on a general operation 

screen

2 . Press 

����

3 .  Adjust days between regenerations using 

UP

 and 

DOWN

 buttons

4 . Press 

����

5 .  Adjust time of regeneration hour with 

UP

 

and 

DOWN

 buttons . AM/PM toggles at 12

6 . Press 

����

7 .  Adjust time of regeneration minutes with 

UP

 and 

DOWN

 buttons

8 . Press 

����

9 .  Turn display backlight ON or OFF with

 UP

 

and 

DOWN

 buttons . Default is ON . 

10 .   Press 

����

 to complete and return to 

normal operation

DAYS BETWEEN REGEN

SET

3

REGEN TIME HOUR

AM

SET

12:00

REGEN TIME MINUTES

AM

SET

12:00

LIGHT NORMALLY

SET

ON

TIME OF DAY

MON

GPM

2:40

8

PM

REGEN

UP

DOWN

NEXT

CLOCK

REGEN

UP

DOWN

NEXT

CLOCK

REGEN

UP

DOWN

NEXT

CLOCK

REGEN

UP

DOWN

NEXT

CLOCK

REGEN

UP

DOWN

NEXT

CLOCK

Quick Reference

Summary of Contents for HFAIR-1054

Page 1: ...lter Iron and Sulfur Air Draw Filters OWNER S MANUAL AND INSTALLATION GUIDE For Models HFFE 1054 HFFE 1354 HFHS 1054 HFHS 1354 HFAIR 1054 HFAIR 1354 100037741 100037742 100037739 100037740 100037743 1...

Page 2: ...rranty 26 Quick Reference Guide 27 YOUR WATER TEST Hardness______________________ gpg Iron___________________________ ppm pH____________________________ number Nitrates_______________________ ppm Mang...

Page 3: ...and days to a regeneration are optional displays For more explanation consult the operating displays and maintenance section Pressing the NEXT button on a general operating screen will cycle through...

Page 4: ...er flows through the control valve for normal operation of a water softener or filter During the regeneration cycle this position provides regeneration water to the unit while also providing untreated...

Page 5: ...subjected to room temperatures under 33 F 4 Do not subject the tank to any vacuum as this may cause an implosion and could result in leaking If there is a possibility a vacuum could occur please make...

Page 6: ...o a subsurface drainage system or other safe location Remember to follow all local codes When installing the drain line on any backwashing filter especially filters that utilize air as the regenerant...

Page 7: ...is necessary to relieve the pressure from the system Place filter into by pass mode Fig 2 Page 4 and release pressure by manually stepping through an entire regeneration sequence This will adequately...

Page 8: ...REGEN UP DOWN NEXT CLOCK REGEN UP DOWN NEXT CLOCK TIME OF DAY MON GPM 2 40 8 PM Press NEXT to cycle to the next step or REGEN to return to the previous step STEP 1 Press and hold the NEXT and UP butt...

Page 9: ...ing steadily to the drain clear and without the presence of air slowly open the inlet valve Restore power and momentarily press the button to advance the control to the REGENERANT DRAW DOWN position 4...

Page 10: ...is installed GPM flashes on the display when water is being treated indicating gallons per minute flowing through the system 2 REGENERATION MODE Typically a system is set to regenerate at a time of no...

Page 11: ...ERROR appears and flashes alternately with the dealer name and phone number record the ERROR number and contact your servicing dealer promptly This indicates that the control valve was not able to fu...

Page 12: ...TER on PC board C Restricted stalled meter turbine C Remove meter and check for rotation or foreign material D Meter wire not installed securely into three pin connector D Verify meter cable wires are...

Page 13: ...el in regenerant tank G Check refill setting in programming Check refill flow control for restrictions or debris and clean or replace H Damaged seal stack assembly H Replace seal stack assembly I Cont...

Page 14: ...osition or disconnect power supply from PC board for 5 seconds and then reconnect B PC board not properly snapped into drive bracket B Properly snap PC board into drive bracket and then Press NEXT and...

Page 15: ...GEN buttons for 3 seconds to resynchronize software with piston position or disconnect power supply from PC board for 5 seconds and then reconnect Then reprogram valve to proper setting B MAV NHBP mot...

Page 16: ...losed The alarm buzzer will activate and the screen will display the error A Check for low flow leak Press NEXT and REGEN buttons for 3 seconds to resynchronize software with piston position or discon...

Page 17: ...o Part No Description Qty 1 CV4381 01 Hague Filter Cover 1 2 CV3107 1 Motor 1 3 CV3002A Drive bracket spring clip Includes 5 6 1 4 CV4377WF WF Replacement Board 1 5 CV3110 Drive gear 12 x 36 3 6 CV310...

Page 18: ...V3011 1 piston assembly downflow 1 CV3011 01 1 piston assembly upflow 1 CV3407 1 25 piston assembly downflow 1 5 CV3174 Regenerant piston 1 6 CV3001 1 body assembly downflow 1 CV3001UP 1 body assembly...

Page 19: ...1 CHECK VALVE ASSEMBLY Item No Part No Description Qty 1 CH4642 WR A Air check valve assembly 1 Although no tools are necessary to assemble or disassemble the valve the Service Wrench shown in variou...

Page 20: ...V3010 1F F injector assembly CV3010 1G G injector assembly CV3010 1H H injector assembly CV3010 1I I injector assembly CV3010 1J J injector assembly CV3010 1K K injector assembly not shown CV3170 O ri...

Page 21: ...08 04 FTG Drain 1 Strt No Sil 1 Water flow Proper DLFC orientation directs water flow towards the washer face with rounded edge DRAIN LINE ASSEMBLY 3 4 Item No Part No Description Qty 1 CH4615 Elbow l...

Page 22: ...Part No Description Qty 1 OZ1 A Ozone Kit Assembly 1 2 OZ1 CASE Enclosure Top Bottom and Clip cover not shown 1 3 33217 WRP3 Ozone Cell 1 not shown CJCPG 6PBLK 3 8 Compression Nut 1 not shown CH4642WR...

Page 23: ...OLVENT Item Part No Description Qty CV3007 07 1 1 4 1 1 2 PVC solvent assembly 2 4 CV3352 Fitting 2 3 4 BRASS SHARK BITE Item Part No Description Qty CV3007 12 3 4 brass shark bite assembly 2 4 CV3628...

Page 24: ...24 Hague Filter Owner s Manual This page intentionally left blank...

Page 25: ...1 0 1 0 pH Range 6 8 to 9 0 6 8 to 9 0 Total Dimensions 10 W x 52 H 13 W x 62 H Weight Filled Lbs 106 5 164 Sulfur Filters Iron Air Filters 1 Op onal Ozone Generator not recommended for use on lters...

Page 26: ...d is owned by the original owner This warranty does not cover expendable or misapplied medias or damages due to accident re ood freezing or any other Act of God We are not responsible for damages due...

Page 27: ...DOWN buttons AM PM toggles at 12 3 Press 4 Adjust minutes with UP and DOWN buttons 5 Press 6 Adjust current day with UP and DOWN buttons 7 Press to complete and return to normal operation CURRENT DAY...

Page 28: ...100037746 RevA0120 Iron and Sulfur Air Draw Filter Hague Quality Water Int l 4343 South Hamilton Road Groveport OH 43125 Phone 614 836 2115 Fax 614 836 5349...

Reviews: