background image

1.  Turn off the cold water supply under the sink.

2.  Turn on the kitchen faucet to release pressure and allow water to drain from the line.

3.  Disconnect the cold water line from the bottom of the kitchen faucet. Attach threaded  

ends of supplied brass tee to the cold water supply line and shut-off valve; tighten using 
an adjustable wrench.

4.  Attach ¼” white tube to the brass tee by following the steps below:

1.  Select an easily accessible area under the sink to 

mount system manifold. To help gauge the right 
location for your system manifold, insert first and 
third stage filter sumps into manifold. Insert sumps by 
aligning top connection points and push up and to the 
right until sumps are locked in. Allow at least 4 to 6 
inches of clearance between the bottom of the filters 
and the floor to allow ample space to change filters.

1.  On the nipple on top of the tank, apply plumber’s  

tape 4 or 5 times in the same direction as the threads.

2.  Hand tighten the tank connector onto the tank nipple 

until secure.  

NOTE: Do not cross thread or over tighten.

3.  Using mount stand, place tank near the system 

manifold. Measure ⅜” white tubing to your original 
“cut” marks to ensure accuracy. Cut ⅜” white tubing.

A. Slide the compression nut onto the white tubing.

B. Slide the plastic sleeve onto the white tube.

C. Place brass insert into the opening of white tube.

D. Push the tip of the white tubing into the opening of the brass tee.

E. Slide the compression nut onto the threads of the brass tee.

F. While holding the white tube in place, tighten the compression nut to compress  

the plastic sleeve and create a seal. 

NOTE: Use a wrench to ensure complete seal. 

Avoid over tightening.

 

Do not connect the other end at this time.

1 INSTALL BRASS TEE FITTING

3 INSTALL WATER STORAGE TANK

2 INSTALL SYSTEM MANIFOLD

OptimH2O™

A

B

C

D

E

F

2.  Make sure the manfold is level. Mark wall 

placement for mounting screws using built-in 
bracket on back of manifold. 

3.  Drill two pilot holes for mounting brackets  

using ⅛” drill bit for.  

NOTE: Use caution not to drill into  
anything beyond the cabinet wall.

4.  Insert mounting screws into the wall leaving approximately ⅜” of each screw exposed.

5.  Remove the sumps from manifold by turning each sump to the left and pulling down before 

hanging manifold on wall. Mount manifold on wall and tighten screws. Do not over tighten.

4.  Install the ⅜” white tubing to the tank. Slide the compression nut onto the white tubing. 

Slide the plastic sleeve onto the white tube. Place brass insert into the opening of white tube.

Summary of Contents for HW-RO-B

Page 1: ...OWNER S MANUAL INSTALLATION GUIDE Quality Water International Hague Reverse Osmosis HW RO B...

Page 2: ...torage Tank Step 4 Install Faucet BOX CONTENTS PLAN FOR INSTALLATION INSTALLATION OVERVIEW PREPARE SITE FOR INSTALLATION Advanced plumbing knowledge Tape Measure Utility Knife Screwdriver Phillips 32...

Page 3: ...s to ensure accuracy Cut white tubing A Slide the compression nut onto the white tubing B Slide the plastic sleeve onto the white tube C Place brass insert into the opening of white tube D Push the ti...

Page 4: ...o countertop by tightening toggle bolts alternating between left and right sides to tighten evenly Leave loose to adjust faucet body as desired 3 Route the 3 tubes attached to faucet body through the...

Page 5: ...tubing 2 Attach red tubing to the 90 elbow until it stops 3 Attach 90 elbow to the membrane drain port 5 Faucet to Drain Connector red tubing from faucet 1 Take the red tubing from faucet and insert i...

Page 6: ...ant Bleach must be completely removed from system before drinking water See Purge instructions below PRESSURE TEST Important Complete sanitization prior to pressure test 1 Open cold water supply valve...

Page 7: ...ic in water has no color taste or odor It must be measured by a laboratory test Public water utilities must have their water tested for arsenic You can get the results from your water utility If you h...

Page 8: ...flow assembly disassemble and reassemble as outlined in Step Six WHAT IS COVERED This warranty covers defects in materials or workmanship in manufacturing of your Hague drinking water filter system ex...

Page 9: ...Quality Water International 4343 S Hamilton Road Groveport OH 43125 614 836 2115...