SECTION 3 –
OPERATING YOUR NTB
3-18
NOTE: Refer to the “60’ NTB Layout”
illustration provided in Section 1 -
Introduction elsewhere in this
manual to aid in identifying the
various sections of the NTB.
3. Enter desired value (ranging from -1200
to 1200 milli-amps), then press OK.
NOTE: The lower the value, the further the
NTB section will push into the
ground. The higher the value, the
higher the NTB section will raise out
of the ground.
4. Press OK.
Forced Float Operation
If the NTB will not enter a Float state,
there may be a sensor malfunction.
Therefore, Float operation may be forced for
field operation.
1. Press the 60’ NTB Setup Button (located
on the Machine Display - Settings Page).
2. On the “60’ NTB Adjustments” screen,
press EDIT (next to Section 1 Force
Float).
3. Press YES to enable Section 1 Force
Float, then press OK.
4. Press OK.
NOTE: Change Section 1 Force Float to NO
for road transportation and to avoid
unwanted tool bar movement.
60’ NTB Adjustments Screen
60’ NTB Setup Button
(Located on the Machine Display -
Settings Page)
60’ NTB Adjustments Screen