I-LS02111
www.hagerco.com
17
Rev 1, 5/16
If the setting is successful, then the buzzer will beep once with a green light. If the
setting fails, then the buzzer will beep three times with a blinking red light.
The setting sequence will be exited if the idle time is more than 20 seconds, or [#] is
pressed to exit immediately.
P=0: Deactivate Lockout Mode
P=1: Activate Lockout Mode
3.1.15.
Passage Mode (Activate / Deactivate)
A Passage Mode activation period needs to be programed before this mode can be
activated. See 3.1.6, Setting Passage Mode Active Period for details. This code
activates or deactivates the Passage Mode, so that the lock can operate in free passage for
a period of time every day, where no credentials are required to gain entry.
Use the code below to activate or deactivate passage mode:
[
*
] [Master or Manager code] [
*
] [61] [
*
] [P] [
*
]
If the setting is successful, then the buzzer will beep once with a green light. If the
setting fails, then the buzzer will beep three times with a blinking red light.
The setting sequence will be exited if the idle time is more than 20 seconds, or [#] is
pressed to exit immediately.
P=0: Deactivate Passage Mode
P=1: Activate Passage Mode
3.1.16.
Activate Audit Trail Connection Mode
NOTE: Audit trail feature can be accessed by purchasing our 34K1 Software Kit (P/N 2-639-
6000).
Connection Mode should be activated if you want to make a connection between the lock
and PC software-SecurPass.
To activate the audit trail connection, complete the steps below:
1.
Open the PC software-SecurPass 34K1
NOTE:
In Lockout Mode, user access codes do not work. Only the Master Code
will grant access. If a regular access code is entered, the buzzer will
beep three times with a blinking red light.
Lockout Mode overrides Passage Mode.