PACKAGING
WARNING:
CHECK THE CONDITION OF THE PACKAGING AND THE
GOODS UPON RECEIPT, ESPECIALLY IF THE PACKAGING
SHOWS ANY VISIBLE DAMAGE. IF IT DOES, POINT
THIS OUT TO THE TRANSPORTER IMMEDIATELY.
THE MANUFACTURER DENIES ALL RESPONSIBILITY
FOR TRANSPORT.
The shower booth must be assembled in the place
where it is to be installed, building permitting.
Assembly requires 2 people.
In the shower booth packaging (200x106x98) you will
the following:
- shower tray;
- all wall panels
- top;
- glass panels
- electronic set with boiler (for models with Turkish bath)
- assembly and use manual.
Check the condition of these items prior to proceeding
with installation.
Before proceeding with installation, ensure that the prepared con-
nections match the spe cations on the technical data card of the
model to be installed. Ensure that the walls above the shower tray
are completely straight. It is advisable to install two
closures
in the water
ures. For models with a thermostatic device, these
are provided with the product.
The product must be installed by authorised or qualified personnel, both
as regards the electrical and plumbing connections. Before connecting
the booth, the installer must make sure that the electrical system complies
with CEI 64.8 standards, the it is protected by a differential switch 0.03A,
and that the earthing system is efficient and complies with the
aforementioned provisions. It is necessary to incorporate in the power
supply network a disconnecting device with a contact opening distance
which allows complete disconnection in the conditions of the overvoltage
category III, in accordance with the installation rules.Connections to the
electrical system must be made with an omnipolar switch with a contact
aperture of at least 3mm, placed outside the safety zones as set forth in
the latest edition of technical standard CEI 64-8/7 (it must be from splashes
or the water supply (see drawing). The electrical system connection wire
must be protected by a corrugated tube with no joins or intermediate
connections. The wire must not have characteristics inferior to those of type
H05VV-F its section must be sized according to the model. The components
used for connection must have specifications and IP protection as set forth
in standard 64.8 for applicatin in bath and showers.
EQUIPOTENTIAL CONNECTION
The appliance should be connected to the earth system
of the building by means of the appropriate terminal located
on the frame of the tray and properly marked as
set forth by
standards 60335.2.60.