background image

12

1

1

B1

A1

3mm

1

 PHASE 8

ATTACHING THE FIXED GLASS PANELS

 PHASE 7

INSERTING THE CLOSURE

Hold  the  closure  so  that  it 
rests perfectly on the com -
pensator  profiles,  and  use 
a 3 mm bit to drill through 
the  six  holes  provided  in 
the profile.
Fasten the closure using the 
screws  “A1”   and  the  cap 
with washer  “B1”   (fig.1).

Place  the  closure  on  the 
shower  booth  and  lower  it 
until the hollow of the lower 
profile  fastens  onto  the 
shower tray profile.
Make  sure  that  the  gasket 
“E1” ,  previously  glued  to 
the fixed profiles of the clo -
sure, does not come free.
Make sure that the closure 
is  perfectly  positioned  on 
the shower tray.

Summary of Contents for NEW BI-SIZE Integra Series

Page 1: ...nstructions and user NEW BI SIZE Shower booth 70 80 x 90 RH LH 80 85 x 80 85 90 x 90 Edition 15 02 2019 GRUPPO GEROMIN S r l reserves the right to make changes to the product at any time without giving any notice ...

Page 2: ...ing s electrical that the earthing system is efficient refer to standard 64 8 The product must be installed by authorised or qualified personnel both as regards the electrical and plumbing connections Before connecting the booth the installer must make sure that the electrical system complies with CEI 64 8 standards the it is protected by a differential switch 0 03A and that the earthing system is...

Page 3: ... specifications Caratteristiche idrauliche Overall dimensions A Kw maximum water operating connections hydro consumption pressure nozzles H C water drain Dim Shower booth packaging Length Width Height Net Weight Gross Volt Hz 106 106 98 98 67 64 87 83 INTEGRA 1 5 3 0 12 1 2 40 50 200 lt min 15 JUNIOR 9 6 2 2 50 230 1 5 3 0 12 1 2 40 50 200 lt min 15 8 0 8 6 8 6 114 43 8 0 105 9 0 8 0 113 43 MOD 70...

Page 4: ...ableforthepower kW oftheproducttobe connected locatedoutsidezones0 1 2 3 andfarfrompossiblewatersplashes The product must also be connected to the equipotential system of the building by means of the appropriate terminal located on the frame Itmustalsobepossiblefortheshowerboothtoberemovedatanytime withouthavingtocarryoutanyoperationsonthemasonry WARNING ifthegiveninstructionsarenotobserved oronly...

Page 5: ...ecting the booth the installer must make sure that the electrical system complies with CEI 64 8 standards the it is protected by a differential switch 0 03A and that the earthing system is efficient and complies with the aforementioned provisions It is necessary to incorporate in the power supply network a disconnecting device with a contact opening distance which allows complete disconnection in ...

Page 6: ...Dowel ACMTASS0006 I 2 Screw 4 2x50 ACMVITI10014 M 2 Seal GUARNBOX0005 N2 L HARDWARE FITTINGS KIT FOR SHOWER BOOTH in main packaging A1 6 Screws 3 5x16 6954 9 Screw cover cap ACMCAPPUC001 8 Screw 3 5x25 3 Screw 3 5x22 B1 C1 D1 Seal cap XGUARN000012 E1 F1 2 Magnetic seals XGUARN000013 2 Seal Door 25 mm XGUARN000014 2 Glass panel seal 16 mm XGUARN000015 2 2 Seal 4 mm XGUARN000016 G1 H1 I1 Seal 4 mm X...

Page 7: ...io NEW BI SIZE Box docc ia 7 0 8 0 x 9 0 D X S X 8 0 8 5 x 8 0 8 5 9 0 X 9 0 Q ty Pos Description BEARING KIT in hardware fittings kit for glass panels ASSEMBLY AND USE MANUAL KIT A4 Q ty Description Pos 1 Boiler with electronics 1 Silicone steam hose TUBA2SILICO1 2 1 Clip CN 15 25 ACMFASCCN025 2 Clip CN 08 16 ACMFASCCU001 2 Screws M6x35 ACMVITI10019 2 Screws ACMROND10002 STEAM KIT B4 C4 Connector...

Page 8: ...the F4 hose to the hose coupler with the clamp G4 fig 2b Screwthenuts B ontothe feet A then insert them intotheappropriatebushes of the shower tray fig 3 Position the shower tray depending on the chosen model for 70x90 position on the RH fig 4b 70x90 or 80x80 position on the LH fig 4c fig 4a checking that it is perfectly level Leveltheshowertraybyad justingitsfeet lockingthem into the required pos...

Page 9: ...he shower tray fig 1 check that it is flush with the in ternal edge of the shower tray and fasten it using the screws G and the washer H provided fig 2 Remove the protective film from the sponge seals N fig 1 and insert them into the compensator profiles of the panel fig 2 Cut away any extra parts fig 3 ...

Page 10: ...SS PANELS PHASE 4 ASSEMBLING THE GLASS PANELS Apply plenty of silicone to the given points fig 1 Assemble the two glass panels with the top and bot tom runners fig 2 Fasten together the as sembled glass panels using the screws C1 provided fig 3 ...

Page 11: ... fig 1 and insert it into the inside of the closure fig 2 Use liquid soap to make this operation easier Apply plenty of silicone to the bottom part of the hollow on the vertical alu minium profile to create a cap fig 3 WARNING Incorrect sili cone application might result in leaks Clean any silicone residue with a clean cloth ...

Page 12: ...e six holes provided in the profile Fasten the closure using the screws A1 and the cap with washer B1 fig 1 Place the closure on the shower booth and lower it until the hollow of the lower profile fastens onto the shower tray profile Make sure that the gasket E1 previously glued to the fixed profiles of the clo sure does not come free Make sure that the closure is perfectly positioned on the shower tra...

Page 13: ...f the doors fasten them with the screws C2 and cover with the screw cover cap B2 fig 1 2 Insert the bottom bearings D2 into the bottom part of the doors in the same way and cover with the screw cover cap B2 Inserttheseals G1 I1 L1 only for models with Turkish bath and the magnetic seal F1 fig 3 4 Attach the handles M1 using the appropriate grub screw N1 fig 5 ...

Page 14: ... 5 6 7 Fasten the seal H1 to the fixed glass panels fig 8 Check sliding and that the two doors line up If neces sary adjust the top slides with the key provided for this purpose in the closure kit WARNING To prevent wa ter leakage after installing the doors check that the sealing strip H1 on the fixed glass panels sticks perfectly to the bottom profile of the closure 6 5 7 8 H1 G1 G1 L1 L1 I1 I1 ...

Page 15: ...r tray fig 2 Fasten it at the ends with the screws G the wash ers H and the appropriate plates E fig 3a and in the middle with the screw G the washers H and the nut I fig 3b Complete this operation by fastening the brackets F to the top without fastening them completely fig 4 2 1 H F G 4 E H G H G I H 3a 3b ...

Page 16: ...wo stainless steel flexible hoses 120cm not provided fig 3 It is advisable to insert two filter closures into the water connections provided for models with thermostat B3 fig 2 Connect the water supply hose fig 4 the steam hose fig 5 the boilder drain hose fig 6 and the boiler wash hose fig 7 Attach the flexible hose to the shower and the ap propriate water connection fig 8 1 4 5 6 7 For mod 70x90 For mod ...

Page 17: ...or mally open relay contact to which the alarm circuit can be connected in com pliance with legal require ments and specific national standards The power sup ply to the alarm circuit can be either 220 240 volt or low voltage with maximum absorption of 10 A Con nections to the alarm circuit must be carried out using a cable that is not inferior to type H 05 VV F 2X1 5 square millimetres LIGHT For mo...

Page 18: ...cture is straight and mark the holes for fastening and the top of the brackets fig1 Movetheshower booth away again and drill the holes with a 6 mm bit Remove thebrackets F andfastenthem to the wall using the dowels L thescrews M andthewashers H provided fig 3 Connect the hose A3 to the drain run a test cycle for all functions checking for correct operation and perfect water tightness Position the sh...

Page 19: ...r p s n o i t c n u f d e r i s e d e h t t c e l e s o T turn the upper dial A until reaching the desired function To open or adjust the water ow intensity always use lever A C TEMPERATURE ADJUSTMENT B To adjust the water temperature turn dial B positioning the selected temperature upwards to 12 o clock The dial is equipped with a safety button C to protect against scalding to increase the temper...

Page 20: ... key Radio FM Allarm Only for version Junior Keyboard functions 1 ON OFF General Pressing the button illuminates the backlight with the enabling of Turkish bath and radio functions To the active system while holding down the key for 2 seconds all functions are immediately available and the system returns standby Figure 2 Standby display Hello Hello 10 Chromotherapy ...

Page 21: ...ature has been reached the turkish bath pauses it is reactivated to maintain the heat status constant The length of the session 5 to 60 minutes is displayed in the bottom left display the keys allow and you to edit it By pressing the button for at least 2 seconds the Turkish bath will off Figure 5 Radio Memory Figure 4 Radio 3 RADIO Press the button to turn on the radio to change the volume use th...

Page 22: ... 8 Menu light active energizing cycle Figure 7 Menu light 1 White light and chromotherapy chromoterepia that is composed of energizing relaxing toning cycles the mode Rainbow iris 42 colors you can change the color of the LED lights by pressing the 4 and 6 keys Possible alarms that may appear in the event of a malfunction of the turkish bath Limescale cycle The boiler requires periodic cleaning by...

Page 23: ...le to disconnect the shower booth by turning the multiple pole switch on the power supply line to the OFF position 10 11 Close the water and electricity supply of the product in case of absence of long periods 12 Replace the hoses after a period of 10 years the replacement must be anticipated in case of visible deterioration of the hose itself The product is guaranteed according to the conditions ...

Page 24: ...GRUPPO GEROMIN S r l Via I Maggio n 5 zona Industriale 30029 San Stino di Livenza VE Tel 39 0421 312249 39 0421 312250 http www gruppogeromin com email info gruppogeromin com ...