background image

 

 

 

 

5.52.172.01.01.08 

 

 

11 

 

Transport and Storage 

 

   

CAUTION!

 

Transport  may  only  be  done  by  qualified  personnel.  No  liability  for  any  damage  resulting  from  improper 
transport or improper storage. 

 

3.1 

Transport 

 The devices are checked and if so adequately packed before delivery. 

  Do not throw or drop the equipment.  

  Use adequate means of transport. 

Transport and means of transport must be suitable for the local conditions. 

3.2 

Safety device for transport 

 

NOTICE!

 

Should a safety device for transport exist, please remove it before commissioning. 

3.3 

Storage 

  Store the equipment at a clean and dry place. 

  Protect the equipment against dirt, humidity and damage by an appropriate cover. 

  Protect hooks, wire ropes, chains and brakes against corrosion. 

 

 

   

DANGER!

 

Units that show corrosion must be taken out of service!

 

 

Description  

 

 

 

4.1 

Areas of application 

The devices must be as far as possible installed in a covered room. 

If they are used in the open, protect the units against the effects of weather such as rain, hail, snow, direct 
sunshine,  dust,  etc.  -  we  recommend  to  use  a  cover  in  parking  position.  If  the  device  is  set  up  in  a 
continuously  humid  environment  with  strong  temperature  fluctuations,  the  correct  functionings  are 
endangered by the forming of condensation. 

 

NOTICE!

 

Use only in the intended atmosphere with a humidity of up to 100%, but not under water! 

 

Depending on the type of device, it is suitable for use in area at risk from explosion in the EX-classification 
stated. 

The EX-classification is mentioned on the EX-type plate on the hoist. The use of the unit is only allowed for 
the EX-classification mentioned on the EX-type plate or lower EX classification.  

 

 

 

   

DANGER!

 

In particular, use is not permitted: 

    for tearing loose fixed loads, dragging of loads as well as diagonal pulling  

   for pulling against a fixed point without additional safety and/or measuring equipment against exceeding 

the nominal load 

    in  potentially  explosive  atmospheres,  unless  the  equipment  has  been  modified  for  this  purpose  and                    

this is shown on special type plates it carries for this purpose. 

    in reactor containments 

    for transporting persons  

    for holding lifted loads 

    for scenic use 

    when persons are under suspended loads 

 

 

Summary of Contents for 27/12-EX

Page 1: ...D Ex h IIIA T135 C Db II 2G Ex h IIB T3 Gb or II 2D Ex h IIIA T200 C Db DANGER Not to be used with IIC gases and IIB gases hydrogen sulphide and ethylene oxide and light metal and shock sensitive dust...

Page 2: ...y 3 2 1 Warning notice and symbols 4 2 2 Duty of care of the owner 4 2 3 Requirements for the operating personnel 4 2 4 Appropriate use 5 2 5 Basic safety measures 5 2 6 Explosion protection 7 3 Trans...

Page 3: ...to explosion complies with current legislation standards and regulations and is classified in the applicable Ex protection class The stated performance of the devices and meeting any warranty claims...

Page 4: ...ver in everyday operation this degree of safety can only be achieved if all measures required are taken It falls within the duty of care of the owner user of the devices to plan these measures and to...

Page 5: ...parts must be used Non compliance will result in any warranty claims becoming void Liability and warranty will become void if unauthorized modifications of the units are made by the user The permissib...

Page 6: ...rged the housing may not be in contact somewhere Stop lowering the load when the bottom block or the load is being set down or is prevented from being lowered further The loose chain end may not be ch...

Page 7: ...ove it with a wet bolt of cloth Defective units or units that show abrasion of its surface rust on chains hooks or suspension devices must be taken out of service Please observe the prescribed interva...

Page 8: ...0 C limit temperature 300 C limit temperature 200 C limit temperature 135 C limit temperature 100 C limit temperature 85 C Gb EPL equipment protection level Ga Gb Gc e g Group II for gases vapours mis...

Page 9: ...mperature class Ignition tem perature of gas C max surface temperature of the operating material in C T1 450 450 T2 300 450 300 T3 200 300 200 T4 135 200 135 T5 100 135 100 T6 85 100 85 2 6 3 EX zone...

Page 10: ...10 5 52 172 01 01 08 2 6 4 Explosion hazards recognizing and preventing...

Page 11: ...in hail snow direct sunshine dust etc we recommend to use a cover in parking position If the device is set up in a continuously humid environment with strong temperature fluctuations the correct funct...

Page 12: ...ll components match precisely to each other Therefore please only use original chains Load hook Forged steel Rotating this facilitates attaching the load and avoids twisting of the chain With safety c...

Page 13: ...hers 6 situated on the load bars 2 of the trolley Dimension X is set by placing washers 6 from the outer to the inner side X increases or from the inner to the outer side X decreases Washers 6 and rub...

Page 14: ...olleys from 4 t up 3 5 mm 1 5 2 5 mm each side bigger than the flange width B of the beam DANGER Assembly disassembly and maintenance operations must only be carried out in an atmosphere not prone to...

Page 15: ...dustrial Safety and Health a hazard analysis must be carried out by the operator Observe the respective national standards regulations and directives of the responsible bodies at the place of operatio...

Page 16: ...trolley drive must be lubricated Hand gear for hand geared trolley Ensure correct fit of the hand chain it must not be twisted and must hang freely 10 2 Functional test Lifting gear Check lifting and...

Page 17: ...ntenance every 3 months Inspection Mainte nance every 12 months Check screw connections X X Check lifting lowering functions X X Check brake function X X Check free wheeling of chain only applicable f...

Page 18: ...e 2 Dimensions mm Chain size 7 1x21 7 9x23 8x24 9x24 8 9x27 10x28 1 10x30 13x36 16x45 L11 238 5 260 6 272 1 281 2 300 8 318 6 340 7 408 3 505 6 L1 22 3 24 1 25 3 26 1 28 1 29 6 31 8 37 9 47 4 dm 6 4 7...

Page 19: ...dn dvmin kg mm mm mm mm 500 6 2 5 5 12 11 4 1000 8 5 8 12 11 4 1500 3000 10 2 9 6 16 15 2 5000 10000 13 12 2 16 15 2 13 Service 13 1 Load chain Wear at the links is mainly due to insufficient maintena...

Page 20: ...on are necessary The teeth must be cleaned and re lubricated after approx 3 years We recommend to use a lubricant of class EP2 or similar products In case of severe conditions of use e g dust regular...

Page 21: ...Kl beroil 4UH 1 1500 Wolfracoat 99113 Chain lubricant OKS 451 13 9 Lubricant for food industry Selection as option SHELL MOBIL CASTROL KL BER Gearing FM Grease HD2 Mobilgrease FM 222 Kl beroil 4UH 1...

Page 22: ...housing and got stuck there Release the hook suspend the load again lower the load unload the hoist Hoist does not lower the load Brake too tight Lift the brake Brake too tight due to rust Replace ru...