background image

 

 

 

 

5.52.172.01.01.08 

 

 

 

  It is not allowed to use the equipment in area at risk from explosion where gas AND dust does both exist 

at the same time! 

  During assembly and operation of explosion-proof equipment, the relevant regulations of i.e. BG-Chemie 

about the use of equipment in area at risk from explosion, must be adhered to by the user/owner. 

  Please make sure that external ventilation is sufficient. 

  Please wear conductive shoes. Gloves should have a shunt resistance of < 10

8

  It is not allowed to take off clothes. 

  The  surface  temperature  of  the  devices  could  increase  by  a  variety  of  external  circumstances.  For  this 

reason, the surface temperature is to be monitored. 

  Avoid ignitable dust deposits. 

  Remove dust deposits daily before commencing work and ensure that dust cannot settle between moving 

parts. 

  Never remove dust with compressed air - remove it with a wet bolt of cloth. 

  Defective  units  or  units  that  show  abrasion  of  its  surface  rust on  chains, hooks,  or  suspension  devices, 

must be taken out of service. 

  Please observe the prescribed intervals. 

  Assembly and maintenance work must only be carried out in an atmosphere not prone to explosion. 

  Check the grease level of the bearings regularly 

  Exchange friction surfaces in time and (an exception to this are electric units - maintenance of the brakes 

must only be effected by HADEF). 

  Protect the device from impact, friction, rough handling and moisture. 

 

 

   

DANGER!

 

The operator is responsible for professional equipotential bonding (earthing) for power-operated 
devices!

 

 

 

Special scope 

Use of different EX-zones is depended from the EX-classification of the unit. Find the EX-classification on its 
type plate. 

 

Unit classified 

in EX-classification 

 

No use 

in EX-zone 

3G 

  0,20,1,21,22 

3D 

  0,20,1,21,2 

2G 

  0,20,21,22 

2D 

  0,20,1,2 

 

 

2.6 

Explosion protection 

The EX classification of the unit is indicated on a 
separate plate, situated on the unit. 

 

 

Illustration 2 

 

 

 

 

Summary of Contents for 27/12-EX

Page 1: ...D Ex h IIIA T135 C Db II 2G Ex h IIB T3 Gb or II 2D Ex h IIIA T200 C Db DANGER Not to be used with IIC gases and IIB gases hydrogen sulphide and ethylene oxide and light metal and shock sensitive dust...

Page 2: ...y 3 2 1 Warning notice and symbols 4 2 2 Duty of care of the owner 4 2 3 Requirements for the operating personnel 4 2 4 Appropriate use 5 2 5 Basic safety measures 5 2 6 Explosion protection 7 3 Trans...

Page 3: ...to explosion complies with current legislation standards and regulations and is classified in the applicable Ex protection class The stated performance of the devices and meeting any warranty claims...

Page 4: ...ver in everyday operation this degree of safety can only be achieved if all measures required are taken It falls within the duty of care of the owner user of the devices to plan these measures and to...

Page 5: ...parts must be used Non compliance will result in any warranty claims becoming void Liability and warranty will become void if unauthorized modifications of the units are made by the user The permissib...

Page 6: ...rged the housing may not be in contact somewhere Stop lowering the load when the bottom block or the load is being set down or is prevented from being lowered further The loose chain end may not be ch...

Page 7: ...ove it with a wet bolt of cloth Defective units or units that show abrasion of its surface rust on chains hooks or suspension devices must be taken out of service Please observe the prescribed interva...

Page 8: ...0 C limit temperature 300 C limit temperature 200 C limit temperature 135 C limit temperature 100 C limit temperature 85 C Gb EPL equipment protection level Ga Gb Gc e g Group II for gases vapours mis...

Page 9: ...mperature class Ignition tem perature of gas C max surface temperature of the operating material in C T1 450 450 T2 300 450 300 T3 200 300 200 T4 135 200 135 T5 100 135 100 T6 85 100 85 2 6 3 EX zone...

Page 10: ...10 5 52 172 01 01 08 2 6 4 Explosion hazards recognizing and preventing...

Page 11: ...in hail snow direct sunshine dust etc we recommend to use a cover in parking position If the device is set up in a continuously humid environment with strong temperature fluctuations the correct funct...

Page 12: ...ll components match precisely to each other Therefore please only use original chains Load hook Forged steel Rotating this facilitates attaching the load and avoids twisting of the chain With safety c...

Page 13: ...hers 6 situated on the load bars 2 of the trolley Dimension X is set by placing washers 6 from the outer to the inner side X increases or from the inner to the outer side X decreases Washers 6 and rub...

Page 14: ...olleys from 4 t up 3 5 mm 1 5 2 5 mm each side bigger than the flange width B of the beam DANGER Assembly disassembly and maintenance operations must only be carried out in an atmosphere not prone to...

Page 15: ...dustrial Safety and Health a hazard analysis must be carried out by the operator Observe the respective national standards regulations and directives of the responsible bodies at the place of operatio...

Page 16: ...trolley drive must be lubricated Hand gear for hand geared trolley Ensure correct fit of the hand chain it must not be twisted and must hang freely 10 2 Functional test Lifting gear Check lifting and...

Page 17: ...ntenance every 3 months Inspection Mainte nance every 12 months Check screw connections X X Check lifting lowering functions X X Check brake function X X Check free wheeling of chain only applicable f...

Page 18: ...e 2 Dimensions mm Chain size 7 1x21 7 9x23 8x24 9x24 8 9x27 10x28 1 10x30 13x36 16x45 L11 238 5 260 6 272 1 281 2 300 8 318 6 340 7 408 3 505 6 L1 22 3 24 1 25 3 26 1 28 1 29 6 31 8 37 9 47 4 dm 6 4 7...

Page 19: ...dn dvmin kg mm mm mm mm 500 6 2 5 5 12 11 4 1000 8 5 8 12 11 4 1500 3000 10 2 9 6 16 15 2 5000 10000 13 12 2 16 15 2 13 Service 13 1 Load chain Wear at the links is mainly due to insufficient maintena...

Page 20: ...on are necessary The teeth must be cleaned and re lubricated after approx 3 years We recommend to use a lubricant of class EP2 or similar products In case of severe conditions of use e g dust regular...

Page 21: ...Kl beroil 4UH 1 1500 Wolfracoat 99113 Chain lubricant OKS 451 13 9 Lubricant for food industry Selection as option SHELL MOBIL CASTROL KL BER Gearing FM Grease HD2 Mobilgrease FM 222 Kl beroil 4UH 1...

Page 22: ...housing and got stuck there Release the hook suspend the load again lower the load unload the hoist Hoist does not lower the load Brake too tight Lift the brake Brake too tight due to rust Replace ru...