11
8.2.
How to replace the wearing parts
When changing any parts use only original HACONA
spare parts. The use of materials that are not original
results in the invalidity of the guarantee.
8.2.1. How to replace the teflon tapes and sealing wire
Used, burned teflon tapes have to be change without delay for safe
operation.
Figure 6 How to replace the teflon tapes and sealing wire
Remove the upper teflon tape
(Figure 6 “1”)
, then unscrew the
fastening screws on the side of the sealing electrode
(Figure 6 “2”)
.
Remove the safety caps of the sealing wire tensioning units
(Figure 6 “3”)
then pulling up the sealing wire
(Figure 6 “4”)
carefully remove from the
machine unit. Remove the teflon tape (
Figure 6 “5”)
attached to the
machine unit.