CONSUMABLES
Typical Replacement Frequency & Consumption
Acid & Base:
4-8 weeks/19 Liters (based on typical ranges and 7.5 minute analysis cycle)
Instrument Air:
1.5 bar, - 20°C dew point (free of water, oil and dust)
Average consumption is less than 5.4 m
3
/hour.
Filter pack is recommended and available to meet the air quality specification.
BioTector Air Compressor is available for air supply.
Service:
6 Monthly Intervals
ANALYSIS PARAMETERS
Oxidation Method:
Patented Two-Stage Advanced Oxidation Process using Hydroxyl Radicals
TOC Measurement:
NDIR measurement of CO
2
after oxidation
Measurement Terms:
TOC (Total Organic Carbon) as Non-Purgeable Organic Carbon (NPOC)
BioTector TIC&TOC mode measures NPOC.
Measured Components:
TOC (NPOC)
TIC
TC
COD*
BOD*
*
COD & BOD by correlation algorithm incorporating TOC measured results
Cycle Time:
from 6.5 minutes, depending on range and application
MONITORING RANGES:
TOC
Standard Range
0-250mgC/l
Accuracy and Repeatability
±
3% of reading or
±
0.45mgC/l, whichever is greater
Detection Limit
0.9mg/l
Second Range
(Optional for Exceedance Tracking)
0-1000mgC/l (
±
4% of reading or
±
2mgC/l, whichever is greater
)
Range Selection:
Automatic or Manual (up to 2 ranges configurable)
SAMPLE & ENVIRONMENTAL CONDITIONS
Sample Volume:
Up to 3.0ml
Sample Inlet Pressure:
Ambient (for applications with high sample pressure, sampling systems are
available)
Drain Pressure:
Ambient (for applications with high drain pressure, optional systems are
available)
Sample Inlet Temperature:
2°C – 60°C
(36°F - 140°F)
Sample Flow Rate:
Minimum 100ml per sample
Sample Particle Size:
Up to 100 microns
Ambient Temperature:
5°C – 45°C
(41°F - 113°F)
Cooling and heating options are available.
Humidity:
5% - 85%, non-condensing
Ingress Protection:
IP44, standard fan cooled, maximum ambient temperature 45°C (113°F)
IP54, air cooled, maximum ambient temperature 35°C (95°F)
IP54, vortex cooled, maximum ambient temperature 50°C (122°F)
System Sound:
< 60 dBa
The manufacturer has a continuous research and development program. Specifications may
therefore be changed without notice. For specification updates, please contact the
manufacturer.
Summary of Contents for BioTector B3500e
Page 17: ...Page 17 Software Menu Diagram...
Page 43: ...Page 43 Figure 4 BioTector analysis layout typical TIC TOC system...
Page 45: ...Page 45 Figure 6 BioTector oxygen concentrator layout...
Page 61: ...Page 61...
Page 73: ...Page 73 Section 8 Maintenance Menu Maintenance Menu Diagram...
Page 152: ...Page 152 Section 11 System Replacement and Spare Parts...
Page 161: ...DOC012 97 80506 User Guidance for EMC Class A Equipment EMC A A A...