Installation of gear reducer
5
If through-holes ( flange B5) are used for fastening, carefully select the length of the fastening screws, which must be long enough
to ensure a sufficiently extended clamping section to ensure correct fastening of the gearbox to the machine.
Before tightening the bolt be sure that the eventual centering of fl anges is inserted properly
Screws must be tightened diagonally with the maximum torque indicated in Table 5.2.1.
In the fastening screws and in the fl ange mating surfaces use
locking adhesives.
Frame size
gear reducer
Dimensions
B5 fl ange
mm
Tightening torque
Ms ± 10%
Strength class 10.9
N m
Ø P
Ø F
S
iC 27, iC 37
120
M6
8
15
iC 27
140
M8
9
35
iC 37, iC 47
140
M8
10
35
iC 27 ... iC 57
160
M8
10
35
iC 37 ... iC 67
200
M10
12
70
iC 57 ... iC 77
250
M12
15
120
iC 77
300
M12
15
120
iC 87
300
M12
16
120
iC 87
350
M12
15
120
iC 97
350
M16
18
290
iC 97
450
M16
22
338
UT.C. 2435
Frame size
gear reducer
Foot mounting screw
UNI5737
(minimum length in mm)
iC 27, iC 37
M8 x 18
iC 47, iC 57
M12 x 24
iC 67
M12 x 30
iC 77
M16 x 30
iC 87
M16 x 45
iC 97
M20 x 55
Table 5.3.1 B5 fl ange hole dimensions
Table 5.4.1 Foot mounting screw dimensions
Attention!
Thoroughly degrease the screws before tightening.
In the event of strong vibrations, heavy-duty cycles, frequent motion reversals, it is always advisable to apply a
suitable threadlocker adhesive such as LOXAEL 23-18 or equivalent on the tnread.
Housing for 4 screws or nuts
(minimum length indicated in the table)
5.3
Flange mounting
5.4
Foot mounting
16
UT.D 208-2021.12-EN
F
S
P