7
January 2004
RESET KEYS
RESET KEYS:
The RESET keys are in the upper left corner of the control keypad.
RESET
Stops all machine motion and places the program cursor at the top of the current program
(Cursor will not Reset to the top if Setting 31, RESET PROGRAM POINTER is OFF).
POWER UP/
After power on, pressing POWER UP/ RESTART will automatically initialize (zero axes)
RESTART
of machine. After zeroing machine, the tool number thats listed in Setting 81, will then be
put into the spindle.
TOOL CHANGER
This key will help to restores the tool changer to normal operation if the tool changer
has encountered an interruption during a tool change. The key initiates a user prompt
screen to assist the operator in recovering from a tool changer crash.
A flow chart showing the steps to restore the side mount tool changer is shown in the
Programming section of the operator manual.