Turn on the illumination of the 0.2mm diaphragm
•
Turn on the crosshairs in EyeSuite, the cross must be inside the illuminated dot
8.2 Servicing
To ensure a long service life, the device should be cleaned weekly as described and
covered with a dust cover when not in use. We recommend having the device in‑
spected by an authorized service technician annually.
8.3 Cleaning and disinfection
The Haag‑Streit slit lamps and their accessories can, if required, be carefully wiped
down with ready‑for‑use disposable 70% ethanol disinfectant wipes. Surface‑friend‑
ly disinfectants (containing aldehyde or aldehyde‑free) are also permitted, such as
Kohrsolin FF.
WARNING!
•
The preparation instructions provided do not apply to tonometer mea‑
suring prisms.
•
Tonometer measuring prisms must be prepared in accordance with a
different manual
•
Do not use sprays
•
Observe the manufacturer's safety instructions
•
Do not use any cloths that drip.
•
Wring out any soaked cloths before use when necessary
•
Ensure that no liquid penetrates the device
•
Comply with the stipulated exposure time
•
Clean optical surfaces after disinfection with a very soft cloth
NOTE!
IP code: IPX0 (device is not protected against liquids)
A. Appendix
A.1 Accessories / consumables / spare parts / upgrade
Components
REF
Set white balance greycards
1021485
Power supply ICCNEXERGY
1022106
Computer cable USB 3.0
1022373
Release module RM02
7220546
B. Statutory requirements
•
The imaging module IM 600 was designed and built taking the EN 60601‑1 and
EN 60601‑1‑2 standards into account.
•
The EN 60601‑1 standard must be observed when using different medical and/or
non‑medical electrical devices in combination.
•
Compliance of the imaging module IM 600 with the Directive 93/42/EEC is con‑
firmed by the CE-designation.
•
You can request a copy of the declaration of conformity for this instrument from
Haag‑Streit at any time.
•
Statutory accident regulations are to be observed.
WARNING!
The imaging module IM 600 may only be operated in an environment
in which standard values pursuant to standard EN 60601‑1 are ob‑
served.
C. Classification
Standard EN 60601‑1
Slit lamp accessories as per protection class I
Operating mode
Continuous operation
CE Directive 93/42/EEC
Class I
FDA
Accessory for slit lamps
D. Disposal
Electrical and electronic devices must be disposed of separately from
household waste! This appliance was made available for sale after the
13th August 2005. For correct disposal, please contact your
Haag-Streit representative. This will guarantee that no hazardous
substances enter the environment and that valuable raw materials are
recycled.
E. Observed standards
EN 60601‑1
EN 60601‑1‑2