3-21
Step4
Use a flat-blade screwdriver to fix the two screws on the RPS plug clockwise to secure the plug to the
RPS DC receptacle (see callout 2 in
Figure 3-29
).
Figure 3-29
Connect an RPS power cord (2)
Step5
Connect the other end of the +12 VDC RPS power cord to the external RPS power supply system.
Step6
Check whether the RPS LED on the front panel of the switch is ON. If yes, the power is properly
connected.
Connecting the RPS Power Cord of the S5500-28C-PWR-SI and S5500-52C-PWR-SI
The S5500-28C-PWR-SI and S5500-52C-PWR-SI can work with RPS1000-A3 using its –54 V/25 A
output and a 0404A053 power cord.
Follow these steps to connect an RPS power cord to the switch:
Step1
Wear an ESD-preventive wrist strap, ensure a good skin contact and make sure that the
ESD-preventive wrist strap is properly grounded.
Step2
Keep the upside of the RPS plug on top and plug it in the RPS DC receptacle (see callout 1 in
Figure
3-30
). (If you plug it upside down, the insertion is not smooth because of the specific structure design of
the RPS DC receptacle and the RPS plug.)
Step3
Use a flat-blade screwdriver to fix the two screws on the RPS plug clockwise to secure the plug to the
RPS DC receptacle (see callout 2 in
Figure 3-30
).
Figure 3-30
Connect an RPS power cord to the S5500-28C-PWR-SI/S5500-52C-PWR-SI
Step4
Connect the other end of the RPS DC power cord to the external RPS power supply system.
Step5
Check whether the RPS LED on the front panel of the switch is ON. If the LED is ON, it shows the power
cord is properly connected.