1-20
Configuring the NQA Statistics Function
NQA puts the NQA tests completed in a specified interval into one group, and calculates the statistics of
the test results of the group. These statistics form a statistics group. You can use the
display nqa
statistics
command to view information of the statistics group, and use the
statistics interval
command to set the interval for collecting statistics.
When the number of statistics groups kept reaches the upper limit, if a new statistics group is generated,
the statistics group that is kept for the longest time is deleted. You can use the
statistics max-group
command to set the maximum number of statistics groups that can be kept.
A statistics group is formed after the last test is completed within the specified interval. A statistics group
has the aging mechanism. A statistics group will be deleted after it is kept for a period of time. You can
use the
statistics hold-time
command to set the hold time of a statistics group.
Follow these steps to configure the NQA statistics function:
To do…
Use the command…
Remarks
Enter system view
system-view
—
Enter NQA test group view
nqa entry admin-name
operation-tag
—
Enter test type view of the test
group
type
{
dlsw
|
ftp
|
http
|
icmp-echo
|
snmp
|
tcp
|
udp-echo
|
udp-jitter
|
voice
}
—
Configure the interval for
collecting the statistics of the
test results
statistics interval interval
Optional
60 minutes by default.
Configure the maximum
number of statistics groups that
can be kept
statistics max-group number
Optional
2 by default.
If the maximum number is 0, it
indicates that no statistics is
performed.
Configure the hold time of a
statistics group
statistics hold-time hold-time
Optional
120 minutes by default.
z
The NQA statistics function is not supported in a DHCP test.
z
If you specify the
interval
argument in the
frequency
interval
command as 0, no statistics group
information is generated.
Configuring Optional Parameters Common to an NQA Test Group
Optional parameters common to an NQA test group are valid only for tests in this test group.
Unless otherwise specified, the following parameters are applicable to all test types and they can be
configured according to the actual conditions.
Follow these steps to configure optional parameters common to an NQA test group: