H3C S5120-9P-SI Installation Manual Download Page 4

About the H3C S5120-SI documentation set 

The H3C S5120-SI documentation set includes: 

Category Documents 

Purposes 

Marketing brochures 

Describe product specifications and benefits.  

RPS Ordering Information for H3C 
Low-End Ethernet Switches 

Provides the RPS and switch compatibility matrix and 
RPS cable specifications.  

Product 
description and 

specifications 

H3C Low End Series Ethernet 
Switches Pluggable Modules 

Manual 

Describes the models, appearances, and 
specifications of the pluggable modules available for 

the products.  

Quick Start Guide 

Provides a quick guide to hardware installation. 

Installation Manual 

Provides a complete guide to hardware installation 
and hardware specifications. 
Provides regulatory information and the safety 

instructions that must be followed during installation. 

Hardware 
installation 

Pluggable SFP[SFP+][XFP] 
Transceiver Modules Installation 

Guide 

Guides you through installing SFP/SFP+/XFP 
transceiver modules. 

Configuration guides 

Describe software features and configuration 
procedures. 

Software 
configuration 

Command references 

Provide a quick reference to all available commands. 

H3C Series Ethernet Switches 

Login Password Recovery Manual  Describes how to find or recover a lost password.  

Operations 

and 
maintenance 

Release notes 

Provide information about the product release, 
including the version history, hardware and software 
compatibility matrix, version upgrade information, 

technical support information, and software 

upgrading. 

 

Obtaining documentation 

You can access the most up-to-date H3C product documentation on the World Wide Web at 

http://www.h3c.com

Click the links on the top navigation bar to obtain different categories of product documentation: 

[Technical Support & Documents > Technical Documents]

 – Provides hardware installation, software 

upgrading, and software feature configuration and maintenance documentation. 

[Products & Solutions]

 –

 

Provides information about products and technologies, as well as solutions.

 

[Technical Support & Documents > Software Download]

 – Provides the documentation released with the 

software version. 

Technical support 

[email protected] 

Summary of Contents for S5120-9P-SI

Page 1: ...H3C S5120 SI Switch Series Installation Manual Hangzhou H3C Technologies Co Ltd http www h3c com Document version 6W105 20110308...

Page 2: ...gzhou H3C Technologies Co Ltd All other trademarks that may be mentioned in this manual are the property of their respective owners Notice The information in this document is subject to change without...

Page 3: ...used in this documentation set GUI conventions Convention Description Boldface Window names button names field names and menu items are in Boldface For example the New User window appears click OK Mu...

Page 4: ...ion guides Describe software features and configuration procedures Software configuration Command references Provide a quick reference to all available commands H3C Series Ethernet Switches Login Pass...

Page 5: ...http www h3c com Documentation feedback You can e mail your comments about product documentation to info h3c com We appreciate your comments...

Page 6: ...r supply system 6 Cooling system 6 S5120 9P HPWR SI 7 Front panel 7 Rear panel 7 Power supply system 7 Cooling system 7 S5120 28P PWR SI 8 Front panel 8 Rear panel 8 Power supply system 8 Cooling syst...

Page 7: ...here a grounding conductor can be buried 30 In other installation sites 31 Connecting the power cord 32 Connecting an AC power cord 32 Connecting an RPS DC power cord 33 Verifying the installation 34...

Page 8: ...d loss 61 Boot ROM password loss 61 Power supply failure 62 Configuration terminal failure 63 Appendix A Lightning Protection of the Switch 64 Installation of Lightning Arrester for AC Power Socket St...

Page 9: ...ces Table 1 and Table 2 show the models and system specifications of the S5120 SI Switch Series Table 1 System specifications for non PoE switches of the S5120 SI Switch Series Item S5120 9P SI S5120...

Page 10: ...imum voltage range 90 VAC to 264 VAC 47 Hz or 63 Hz Input voltage RPS DC Use the external RPS unit provided by H3C only with the rated voltage ranging from 52 VDC to 55 VDC Supported RPS unit RPS1000...

Page 11: ...n the S5120 SI Switch Series are numbered from top to bottom and left to right as Port 1 Port 2 Port 3 and so on Rear panel Figure 2 S5120 9P SI rear panel 1 AC receptacle 2 Grounding screw Power supp...

Page 12: ...4 Console port 5 1000Base X SFP interface Rear panel Figure 4 S5120 20P SI rear panel 1 2 1 AC receptacle 2 Grounding screw Power supply system AC power input Rated voltage range 100 VAC to 240 VAC 50...

Page 13: ...r 4 Console port 5 1000Base X SFP interface Rear panel Figure 6 S5120 28P SI rear panel 1 AC receptacle 2 Grounding screw Power supply system AC power input Rated voltage range 100 VAC to 240 VAC 50 H...

Page 14: ...Power LED Power 5 1000Base X SFP interface 6 1000Base X SFP interface status LED Rear panel Figure 8 S5120 52P SI rear panel 1 2 1 AC receptacle 2 Grounding screw Power supply system AC power input Ra...

Page 15: ...D mode switching button 6 Console port Port 7 1000Base X SFP interface Rear panel Figure 10 S5120 9P HPWR SI rear panel 1 AC receptacle 2 Grounding screw Power supply system AC power input Rated volta...

Page 16: ...D Power 5 Port mode LED 6 Console port Port 7 1000Base X SFP interface Rear panel Figure 12 S5120 28P PWR SI rear panel 1 AC receptacle 2 Grounding screw Power supply system AC power input Rated volta...

Page 17: ...Port 1000Base X SFP interface Rear panel Figure 14 S5120 28P HPWR SI rear panel 1 Screw hole of the plug 2 AC receptacle 3 Grounding screw 4 DC power receptacle Power supply system The H3C S5120 28P H...

Page 18: ...e It can be connected to an ASCII terminal It can be connected to a serial port of a local or remote through a pair of modems PC running terminal emulation program 10 100 1000Base T Ethernet port Each...

Page 19: ...km 24 86 miles SFP GE LH70 SM1550 1550 nm LC 9 125 m single mode optical fiber 70 km 43 50 miles SFP GE LX SM1310 BIDI TX 1310 RX 1490 SFP GE LX SM1490 BIDI TX 1490 RX 1310 LC 9 125 m single mode opti...

Page 20: ...properly Blinking green 1 Hz The system is performing power on self test POST or downloading software Blinking green 3 Hz The POST has failed or another fatal error has been detected Power Off The swi...

Page 21: ...es at a rate of 1000 Mbps Fast blinking Data is being transmitted or received at 1000 Mbps Green Off The port is not up or does not operate at 1000 Mbps On The port operates at a rate of 10 100 Mbps F...

Page 22: ...pply is provided on the port On The device connected to the interface is not a PD device or a PoE failure occurs Blinking green PoE mode Yellow Off No PoE power supply is provided on the port or PoE p...

Page 23: ...a workbench but make sure Adequate clearance is reserved at the air inlet exhaust vents for ventilation The rack or workbench has a good ventilation system The rack is sturdy enough to support the swi...

Page 24: ...gases such as SO2 H2S NH3 and Cl2 For specific requirements see the following table Table 13 Harmful gas limits in the equipment room Gas Maximum concentration mg m3 SO2 0 2 H2S 0 006 NH3 0 05 Cl2 0 0...

Page 25: ...ot stare into the optical port because the laser light emitted from the optical fiber may hurt your eyes Installation tools Flat blade screwdriver Phillips screwdriver ESD preventive wrist strap CAUTI...

Page 26: ...of seal on a mounting screw on the chassis cover intact and if you want to open the chassis contact the local agent of H3C for permission Otherwise H3C shall not be liable for any consequence caused t...

Page 27: ...28P SI Provided by default See callout A in Figure 17 Front or rear part of the chassis s side See Figure 18 and Figure 19 S5120 9P SI Optional See callout B in Figure 17 Front or rear part of the ch...

Page 28: ...mounting brackets varies with devices As shown in Table 14 the mounting brackets can be attached to a switch for front center or rear mounting You can choose a proper position according to the actual...

Page 29: ...t on the chassis B 1 1 Front panel Figure 20 Install a mounting bracket on the chassis C 1 Front panel Figure 21 Install a mounting bracket on the chassis D 1 Front panel Figure 22 Install a mounting...

Page 30: ...ssis G 1 Front panel Figure 25 Install a mounting bracket on the chassis H 1 Front panel Figure 26 Install a mounting bracket on the chassis I 1 Front panel Mounting the switch to a rack Step1 Wear an...

Page 31: ...location Step6 Use another person to fix the mounting brackets with screws anti rust screws with cage nuts prepared by yourself to the square holes of the rack to install the switch to the rack horizo...

Page 32: ...with mounting brackets and trays To do so put the switch on the support tray and slide the switch to an appropriate location and then fix the mounting brackets Mounting the switch on a workbench In m...

Page 33: ...can mount the S5120 9P SI and S5120 9P HPWR SI on concrete or wood walls Table 15 Models supporting wall mounting Model Hole distance S5120 9P SI 98 5 mm 3 88 in S5120 9P HPWR SI 174 0 mm 6 85 in Intr...

Page 34: ...eep only the edges outside the wall as shown in Figure 31 Step3 Drive screws into the anchor kits keeping the inside of screw head at least 1 5 mm 0 06 in away from the edge of the anchor kit so that...

Page 35: ...one permanent magnet and one M3 6 countersunk head screw as shown in Figure 33 Four sets of magnetic mounting accessories are needed for each switch Figure 33 Magnet and countersunk head screw 1 Perm...

Page 36: ...a stable place free from vibrations or shocks Otherwise personal injuries or equipment damage may occur Avoid installing the switch at a high place because bodily injuries or equipment damage may occu...

Page 37: ...rip is available at the installation site attach one end of the yellow green grounding cable of the switch to the grounding screw on the grounding strip the grounding screw and the grounding hole are...

Page 38: ...the grounding cables supplied with the S5120 28P HPWR SI and S5120 28P PWR SI provide OT terminals at the ends connecting the grounding strip For other switch models prepare proper OT terminals by you...

Page 39: ...power distribution room or AC transformer side the switch PE terminal and the PE wire are well connected and the three wire input cable of the grounding cable is used for the power supply cable If the...

Page 40: ...eptacle on the rear panel of the chassis as shown in Figure 39 Step3 Connect the other end of the power cord to a power source Figure 39 Connect the AC power cord A The S5120 9P SI and S5120 9P HPWR S...

Page 41: ...he insertion is not smooth because of the specific structure design of the RPS DC receptacle and the RPS plug Step3 Use a flat blade screwdriver to fix the two screws on the RPS plug clockwise to secu...

Page 42: ...bench is stable The grounding cable is connected The selected power module matches that required by the switch The power cords are properly connected All the interface cables are cabled indoors If the...

Page 43: ...n environment setup Connecting the console cable Console cable A console cable is an 8 core shielded cable One end of the cable is a crimped RJ 45 connector which is connected to the console port of t...

Page 44: ...h H3C recommends you to disconnect the DB 9 connector of the console cable from the PC after disconnecting the RJ 45 connector from the switch Setting terminal parameters When setting up the configura...

Page 45: ...Step2 Type the name of the new connection in the Name text box and click OK The following dialog box appears Select the serial port to be used from the Connect using drop down list Figure 46 Set the...

Page 46: ...38 Figure 47 Set the serial port parameters Step4 Click OK after setting the serial port parameters and the system enters the HyperTerminal window shown below Figure 48 HyperTerminal window...

Page 47: ...ng on the switch verify that The power cord is properly connected The power supply voltage meets the requirement of the switch The console cable is properly connected the terminal or PC used for confi...

Page 48: ...in fast mode and the waiting time here is one second If you set the startup mode to normal the waiting time is five seconds The following section describes the setting of the startup mode If you press...

Page 49: ...e main application file flash S5120 CMW520 A1101 bin The main application file is self decompressing Done System is starting User interface aux0 is available Press ENTER to get started The appearance...

Page 50: ...ng information Starting H3C S5120 28P SI BOOTROM Version 135 Copyright c 2004 2011 Hangzhou H3C Technologies Co Ltd Creation Date Jan 9 2011 CPU Type ARM926 CPU L1 Cache 32KB CPU Clock Speed 333MHz Me...

Page 51: ...ss ENTER to get started indicates that the automatic startup of the switch is complete Press Enter The following prompt is displayed H3C You can configure the switch now NOTE The H3C series switches p...

Page 52: ...grade the applications and boot the system Boot ROM program stored together with application programs in the host software package with an extension name of bin used for upgrade are complete Boot ROM...

Page 53: ...the startup mode to normal the waiting time is five seconds For the setting of the startup mode see Changing the boot mode To enter the Boot ROM menu in fast mode press Ctrl B within one second when...

Page 54: ...ving program checks it using the agreed upon check method If the check succeeds the receiving program sends an acknowledgement character if the check fails it sends a reject character Upon receipt of...

Page 55: ...basic BootRom 0 Return to boot menu Enter your choice 0 3 Table 19 Description of the Boot ROM update menu Item Description 1 Update full BootRom Upgrade the complete Boot ROM file 2 Update extended B...

Page 56: ...ter key when ready Now that the console communication baud rate of the switch has been changed to 1 15200 bps while that of the terminal is still 9600 bps the two sides cannot communicate with each ot...

Page 57: ...elect File Properties In the Properties dialog box click Configure as shown in Figure 51 and then select 1 15200 from the Bits per second drop down list box as shown in Figure 52 Figure 51 Properties...

Page 58: ...rminal and the switch by using the changed rate Press Enter to reestablish the connection between the terminal and the switch and download the boot file at 1 15200 bps The following information is dis...

Page 59: ...ate bin and select Xmodem from the Protocol drop down list Figure 54 Transfer menu Figure 55 File transmission dialog box Step2 Click Send The following dialog box appears Figure 56 Send the boot file...

Page 60: ...OM file effective Press any key to return to the Boot ROM upgrade menu 1 Update full BootRom 2 Update extended BootRom 3 Update basic BootRom 0 Return to boot menu Enter your choice 0 3 Enter 0 to ret...

Page 61: ...The PC and the TFTP server can be the same device Run the TFTP Server program on the sever Required Run the terminal emulation program on the PC connected with the switch s console port Start the swit...

Page 62: ...c BootRom 0 Return to boot menu Enter your choice 0 3 4 Enter the protocol parameter setting menu Enter 1 to upgrade the complete Boot ROM file and then enter the protocol parameter setting menu Bootr...

Page 63: ...e is complete Updating extended BootRom Done 7 Restart the switch to make the upgraded Boot ROM file effective Press any key to return to the Boot ROM upgrade menu Press enter key when ready 1 Update...

Page 64: ...ect the switch to the TFTP server through an Ethernet port and to a PC through the console port The PC and the TFTP server can be the same device Run the FTP Server program on the server Required Run...

Page 65: ...otRom 0 Return to boot menu Enter your choice 0 3 4 Enter the protocol parameter setting menu Enter 1 to update the complete Boot ROM file Bootrom update menu 1 Set TFTP protocol parameter 2 Set FTP p...

Page 66: ...complete Updating Basic BootRom Done Updating extended BootRom Y N Y The system asks you whether you want to upgrade the extended Boot ROM section Click Y and then the system displays the following i...

Page 67: ...et to the switch and send the host program file to the switch using FTP Assume the Boot ROM and boot files are stored in the file named update bin follow these steps after you telnet to the switch Ste...

Page 68: ...rst and then delete certain boot files from the flash memory delete the unused host program files then load the boot file to the switch through FTP for upgrade Avoid any power failure during the loadi...

Page 69: ...dress software name or path of the TFTP server when using TFTP Entering an incorrect IP address software name username or password when using FTP If file loading fails when there are neither physical...

Page 70: ...he RPS DC power cord is correctly connected The RPS power supply is normal The operating temperature of the switch is in the appropriate range and good ventilation is ensured for the power supply unit...

Page 71: ...If there is no output information after the configuration is powered on please check whether The power supply is normal The console cable is properly connected If no problems are found after the abov...

Page 72: ...e You can use cable clips and screws to fasten the lightning arrester for AC power on the cabinet workbench or the wall of equipment room Figure 59 Diagram of lightning arrester 1 Working LED green On...

Page 73: ...und wire of the arrester is not well grounded or because the live and zero wires are connected in reverse direction You may check that in the following way When the red LED is on use a multimeter to e...

Reviews: