81
Member ports of a DR interface cannot be
selected
Solution
Some or all member ports of a DR interface cannot be selected.
Troubleshooting flowchart
Figure 30 Flowchart for troubleshooting member port selection failure on a DR interface
Solution
To resolve the issue:
1.
Verify that the member ports of the DR interface are operating correctly:
a.
Execute the
display interface
command to identify the states of the member ports.
b.
If the member ports are down, locate the cause and resolve the issue.
2.
Verify that the DR system has not split:
a.
Execute the
display drni verbose
command to identify the state of the DR system.
b.
If the DR system has split, resolve the issue as described in "
3.
Verify that the DR member devices have configuration consistency:
a.
Execute the
display drni consistency
command to check for inconsistent type-1
configuration.
b.
If type-1 configuration inconsistency exists, modify the inconsistent settings.
Do the DR member devices pass
configuration consistency check?
Modify inconsistent
configuration
Yes
No
End
Member ports of a DR
interface cannot be
selected
Resolved?
No
Yes
Contact the support