flash:/s12500-cmw710-boot-old.bin
flash:/s12500-cmw710-system-old.bin
# Display the current software images and startup software images on the standby MPU.
<Device> display boot-loader slot 1
Software images on slot 1:
Current software images:
flash:/s12500-cmw710-boot-test.bin
flash:/s12500-cmw710-system-test.bin
Main startup software images:
flash:/s12500-cmw710-boot-test.bin
flash:/s12500-cmw710-system-test.bin
Backup startup software images:
flash:/s12500-cmw710-boot-old.bin
flash:/s12500-cmw710-system-old.bin
Configuration files
#
interface M-GigabitEthernet0/0/0
port link-mode route
ip address 192.168.100.66 255.255.255.0
#
Example: Using the device as an FTP client to upgrade
software
Network requirements
As shown in
, use FTP to download a software upgrade file from an FTP server to upgrade the
device.
Figure 3
Network diagram
Software version used
This configuration example was created and verified on S12500-CMW710-R7328P02.
Configuration restrictions and guidelines
When you upgrade software, follow these restrictions and guidelines:
•
Make sure the device has sufficient storage space for the upgrade file. If the device does not have
sufficient storage space, delete unused files by using the
delete /unreserved
file
-
url
command.
•
Save the configuration before the upgrade for the configuration to survive a reboot.
•
If the device has two MPUs, you must upgrade both MPUs for the device to operate correctly.